The **nVent Heavy-Duty Disconnect Enclosure (SKU: A72XM6618FTCG)** is a robust, Type 12-rated solution engineered for demanding industrial environments where protection, durability, and operational efficiency are critical. Designed and manufactured in the U.S., this gray steel enclosure provides a secure housing for electrical disconnect switches, motor controllers, and other control components, ensuring compliance with NEMA Type 12 standards for dust-tight and drip-proof protection. With dimensions of 72.12 x 66.50 x 18.12 inches, it offers ample interior space for complex wiring configurations while maintaining a compact footprint suitable for tight installation areas. This enclosure is part of nVent’s trusted portfolio of industrial electrical solutions, a company renowned for innovation and reliability in power management, thermal management, and electrical protection systems. The **A72XM6618FTCG** is specifically designed for heavy-duty applications across manufacturing, food and beverage processing, pharmaceuticals, and water treatment facilities—industries where equipment must withstand harsh conditions, including exposure to dust, water, and corrosive agents. Key features of this disconnect enclosure include a **two-door design** for enhanced accessibility during maintenance and inspection, allowing technicians to service internal components without full enclosure removal. The **gray powder-coated steel construction** delivers superior corrosion resistance and long-term durability, even in high-moisture or chemically aggressive environments. Additionally, the enclosure supports **one to six doors**, offering flexibility to accommodate varying system configurations and future expansion needs. Professionals in industrial electrical design and plant operations choose the nVent A72XM6618FTCG for its **cost-effective performance** without compromising on safety or compliance. It meets stringent UL and NEMA Type 12 standards, ensuring reliable operation in applications such as motor control centers, HVAC systems, and machinery disconnects. The enclosure’s **front-opening design** simplifies installation and wiring, reducing labor time and minimizing downtime during setup or upgrades. nVent’s reputation for engineering excellence is backed by decades of experience in providing solutions that enhance operational safety and efficiency. The **A72XM6618FTCG** reflects this commitment, delivering a product that balances rugged construction with practical design elements like **hinged doors with padlockable latches**, tamper-resistant fasteners, and ample knockouts for conduit entry. Whether deployed in a factory automation line, a wastewater treatment plant, or a refrigerated storage facility, this enclosure ensures that critical electrical components remain protected and accessible. For engineers, electricians, and facility managers seeking a **heavy-duty, code-compliant disconnect solution**, the nVent Heavy-Duty Disconnect Enclosure (SKU: A72XM6618FTCG) stands out as a reliable choice. Its combination of durability, flexibility, and cost-effectiveness makes it an essential component in modern industrial electrical infrastructure, where reliability and compliance are non-negotiable.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Removable centerposts permit easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Panel supports
  • Data pocket is high-impact thermoplastic
  • Oil-resistant gasket

Specifications

Application
Arc Flash Safety; Power Distribution; Controls and Drives
Application
Arc Flash Safety;Controls and Drives;Power Distribution
Color
Gray
Conductive Panel
A72PM66G
Depth
460 mm
Depth
18.12
Depth
460
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
1,832 mm
Height
72.12
Height
1,832
Interior Color
Gray
IP Rating
IP55
Material
Steel
Material
Mild Steel
Modification Services
Yes
NEMA Rating
12
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Painted Panel
A72PM66
Panel Included
Yes
Panel Size
60.00 x 60.00 in
Panel Size
1524 x 1524 mm
Protection Rating
NEMA Type 12
Size
72.12x66.50x18.12 inches
Size
72.12x66.50x18.12 in
Stiffener Locations
610 mm
Stiffener Locations
21 in
Thickness
11 ga
Thickness
3.04 mm
Thickness
51.40mm (2.024")
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
828 lb
Width
1,689 mm
Width
66.5
Width
1,689
With or Without Panel
With
Package Dimensions (L x W x H)
84 IN x 36 IN x 82 IN
Package Dimensions (L x W x H)
213.36 cm x 91.44 cm x 208.28 cm
Package Weight (Imperial)
828.000 L
Package Weight (Metric)
375.581 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A24R208NK Controller

This guide provides step-by-step instructions for installing and configuring the A24R208NK Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A24R208NK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage as specified in the manual.

  4. Configure the controller settings

    Access the controller's configuration menu using the interface. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.