Overview

The nVent Sequestr External Disconnect Package (SKU: A90XD5EW18FTCLP) is a critical safety solution designed to mitigate arc flash hazards in industrial and commercial electrical systems. This pre-assembled enclosure package isolates incoming power from the main enclosure, providing a dedicated disconnect switch and fuse block/circuit breaker in a separate, Type 12-rated gray steel housing. By separating high-risk components from primary equipment, the Sequestr External Disconnect Package enhances worker safety, simplifies maintenance, and ensures compliance with stringent electrical safety standards such as NFPA 70E and OSHA regulations. Engineered for new installations, this package ships as a single unit, reducing on-site assembly time and minimizing installation errors. The external enclosure measures 90.12 x 197.75 x 18.12 mm, offering a compact yet robust solution for space-constrained environments. Its Type 12 rating ensures protection against dust, dirt, and non-corrosive liquids, making it ideal for harsh industrial settings, including manufacturing plants, data centers, healthcare facilities, and commercial buildings. The gray steel construction provides durability and corrosion resistance, while the flush-mounted design ensures a professional aesthetic in visible areas. Key applications include: - **Arc Flash Mitigation**: Isolates power sources during maintenance, reducing exposure to hazardous electrical arcs. - **Equipment Isolation**: Enables safe servicing of interior components without disrupting the entire electrical system. - **Code Compliance**: Meets NEC and UL requirements for disconnect switches in industrial and commercial applications. - **Modular Expandability**: Facilitates future upgrades or reconfigurations with minimal downtime. Professionals select the nVent Sequestr External Disconnect Package for its reliability, ease of installation, and alignment with industry best practices. nVent, a trusted leader in electrical solutions, delivers products that prioritize safety, performance, and longevity. The Sequestr series, in particular, is renowned for its innovative design and adherence to rigorous safety standards, making it a preferred choice for engineers, electricians, and facility managers. Whether for new construction or retrofitting existing systems, this package provides a cost-effective way to enhance electrical safety and operational efficiency. Installation is straightforward, with terminal connections designed to bridge power from the external disconnect to the main enclosure. The package includes all necessary hardware and mounting provisions, ensuring a seamless integration into your electrical infrastructure. For optimal performance, ensure proper grounding and adherence to local electrical codes during installation. Regular inspections and maintenance will further extend the lifespan of the enclosure and its components. Choose the nVent Sequestr External Disconnect Package to safeguard personnel, protect equipment, and maintain uninterrupted operations in your facility. With its robust construction, compliance-driven design, and nVent’s reputation for quality, this solution delivers peace of mind for any industrial or commercial electrical system.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by primary door prevents secondary door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Power Distribution; Controls and Drives; Arc Flash Safety
Color
Gray
Depth
18.12 in
Depth
460 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
2,289 mm
Height
90.12 in
Interior Color
White
IP Rating
IP55
Large Panel
A90PM78
Large Panel Quantity
2
Large Panel Size
1981 x 1829 mm
Large Panel Size
78.00 x 72.00 in
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Product Family
Sequestr
Protection Rating
NEMA Type 12
Series
Sequestr
Size
90.12x197.75x18.12 in
Size
90.12x197.75x18.12
Small Panel
A90PM40
Small Panel Size
78.00 x 33.75 in
Small Panel Size
1981 x 857 mm
Thickness
16 ga
Thickness
1.52 mm
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
2,344.75 lb
Width
5,023 mm
Width
197.75 in
Package Dimensions (L x W x H)
208 IN x 36 IN x 98 IN
Package Dimensions (L x W x H)
528.32 cm x 91.44 cm x 248.92 cm
Package Weight (Imperial)
2344.750 L
Package Weight (Metric)
1063.579 kg
Sequestr External Disconnect Pkg Wht In Type 12, 90.12x197.75x24.12, Gray, Steel

A90XD5EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 90.12x197.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x40.25x24.12, Gray, Steel

A84XD4024FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x40.25x24.12, Gray, Steel
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x24.12, Gray, Steel

A84XD4EW24FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x158.00x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x118.75x24.12, Gray, Steel

A84XD3EW24FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x118.75x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 84.12x78.50x24.12, Gray, Steel

A84XD7824FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 84.12x78.50x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 72.12x78.50x24.12, Gray, Steel

A72XD7824FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 72.12x78.50x24.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 90.12x78.50x20.12, Gray, Steel

A90XD7820FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 90.12x78.50x20.12, Gray, Steel
Sequestr External Disconnect Pkg Gry In Type 12, 72.12x78.50x18.12, Gray, Steel

A72XD7818FTCLPG

Sequestr External Disconnect Pkg Gry In Type 12, 72.12x78.50x18.12, Gray, Steel

How to Safely Handle and Install Large Hoffman Enclosures

This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.

Estimated time: 1h

Tools needed:

Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)

Supplies needed:

3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)

  1. Read Safe Handling Requirements

    Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.

  2. Prepare for Movement

    Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.

  3. Position Forklift Forks

    For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.

  4. Secure Enclosure to Forklift

    If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.

  5. Lift and Transport Enclosure

    Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.

  6. End Loading/Unloading (if applicable)

    For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.

  7. Overhead Lifting (if applicable)

    If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.

  8. Final Placement

    Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.