The nVent A72HX6112SSLPQT is a robust, floor-mount disconnect enclosure engineered for superior protection of critical electronic controls and components. Constructed from high-grade SS304 stainless steel, this enclosure offers exceptional resistance to noncorrosive and mildly corrosive elements, making it an ideal solution for demanding indoor and outdoor industrial environments. Its substantial dimensions of 72x61x12 inches provide ample space for housing a wide array of the most popular disconnect switches and circuit breakers, ensuring versatile application across various industrial sectors. Designed with a secure 2-door configuration and a reliable 1/4-turn, 3-point latching mechanism, the A72HX6112SSLPQT ensures a tight seal, meeting Type 4X environmental protection standards. This rating signifies its ability to withstand water, dust, and corrosion, crucial for maintaining operational integrity in harsh conditions. The brushed stainless steel finish not only enhances its aesthetic appeal but also contributes to its durability and ease of maintenance. Typical applications for this premium disconnect enclosure span across vital industries. In the food and beverage sector, it safeguards control systems from washdown procedures and airborne contaminants. The packaging industry relies on such enclosures to protect sensitive automation controls from dust and moisture. For water and wastewater treatment facilities, its corrosion resistance is paramount in humid and chemically exposed environments. Furthermore, the petroleum and chemical processing industries benefit from its robust construction, ensuring the safety and reliability of control equipment exposed to potentially hazardous atmospheres and aggressive substances. When selecting a disconnect enclosure, engineers and facility managers prioritize durability, environmental protection, and ease of access for maintenance. The nVent A72HX6112SSLPQT excels in all these areas. Its floor-mount design offers stability and accessibility, while the 3-point latch system provides enhanced security and sealing integrity. The SS304 material is chosen for its excellent balance of strength, corrosion resistance, and cost-effectiveness in industrial settings. nVent's reputation for quality and innovation in enclosure solutions further solidifies the A72HX6112SSLPQT as a trusted choice for critical infrastructure protection. Key features include: * **Durable SS304 Construction:** Provides superior corrosion and impact resistance. * **Type 4X Rating:** Ensures protection against water, dust, and corrosion. * **2-Door Design:** Offers convenient access to housed equipment. * **1/4-Turn, 3-Point Latch:** Delivers secure closure and sealing. * **Generous Dimensions (72x61x12):** Accommodates a wide range of disconnect switches and circuit breakers. * **Floor-Mount Capability:** Ensures stable and accessible installation. This enclosure is an essential component for any facility requiring reliable protection for electrical control systems in challenging industrial environments. Its robust design and high-quality materials guarantee longevity and operational continuity.
  • 3 Point latching mechanism for simple, reliable one-motion closure
  • Seams continuously welded and ground smooth
  • Seamless foam-in-place one-piece gasket provides water-, oil- and dust-tight seal against contaminants
  • Heavy-duty three-point latching mechanism on each door, operated by nVent HOFFMAN's black die-cast PowerGlide padlocking handle
  • Black die-cast quarter-turn latches with slotted insert provided on the top and bottom of each door
  • Master door is far right-hand door on all enclosures
  • Master door handle provided with integral screwdriver defeater
  • Mechanical interlock activated by master door prevents slave door from being opened first; doors can be closed in any order
  • Concealed hinges provide 180-degree door opening and allow easy door removal and cleaning of hinge area
  • Bolt-on, 15-inch high stainless steel floor stands

Specifications

Application
Corrosive Environments; Controls and Drives; Arc Flash Safety
Application
Arc Flash Safety;Controls and Drives;Corrosive Environments
Body Thickness
2.78 mm
Body Thickness
12 ga
Body Thickness
16 ga
Color
Unpainted
Color
Brushed
Conductive Panel
A72P60G
Depth
306 mm
Depth
12.06
Depth
306
Door Thickness
14 ga
Door Thickness
1.98 mm
Finish
Brushed #4
Height
1,830 mm
Height
72.06
Height
1,830
Ip Rating
IP66/IP67
IP Rating
IP66
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Floor-Mount
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Nema Rating
Type 4X
Panel
A72P60
Panel Size
1727 x 1422 mm
Panel Size
68.00 x 56.00 in
Poles
2
Protection Rating
NEMA Type 12
Quarter-Turn Latch Quantity
4
Size
72.06x61.31x12.06 in
Size
72x61x12
Type
Stainless Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 3R
Weight
476 lb
Width
61.31
Width
1,557
Width
1,557 mm
Package Dimensions (L x W x H)
68 IN x 30 IN x 96 IN
Package Dimensions (L x W x H)
172.72 cm x 76.2 cm x 243.84 cm
Package Weight (Imperial)
476.000 L
Package Weight (Metric)
215.914 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the WS625112SS Controller

This guide provides step-by-step instructions for installing and wiring the WS625112SS controller securely and correctly.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Hole saw or Greenlee-type punch

Supplies needed:

Mounting screws, External toothed lockwashers, Watertight conduit hubs

  1. Install lockwasher

    Place the enclosed external toothed lockwasher under one of the nuts securing the panel to ensure proper bonding between the panel and enclosure.

  2. Cut conduit openings

    Use a hole saw or Greenlee-type punch to cut the required holes for conduit entry in the top, bottom, or side walls of the enclosure, following the size specifications provided.

  3. Install watertight conduit hub

    Install the approved watertight conduit hub according to the manufacturer's instructions, ensuring it fits securely into the holes you have cut.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.