nVent A664CHQRFG - Continuous Hinge QR Cover Enclosure 4X, 6x6x4, Light Gray, Fiberglass
nVent

A664CHQRFG

UPC: 783510297008


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A664CHQRFG is a robust 6.00" x 6.00" x 4.00" continuous hinge QR cover enclosure. Constructed from durable light gray fiberglass, this enclosure is designed to withstand demanding environments. It boasts a NEMA 4X rating, signifying its superior protection against water and dust ingress, as well as corrosion resistance. The innovative continuous hinge design ensures smooth and reliable door operation, facilitating easy access to the enclosure's interior. For secure closure and to maintain the NEMA 4X integrity, the enclosure is equipped with quick-release latches. The fiberglass material itself offers inherent benefits, including excellent dielectric strength and non-conductive properties, making it an ideal choice for applications where electrical insulation is critical. This enclosure is specifically engineered to safeguard sensitive electrical components, controls, and instrumentation. Its suitability extends across various demanding sectors, including water treatment facilities, chemical processing plants, and telecommunications infrastructure, where reliable protection in harsh conditions is paramount.
  • Compression-molded fiberglass has outstanding chemical- and temperature-resistance qualities and exhibits excellent weatherability and physical properties
  • Fiberglass is easily punched, drilled, filed or sawed
  • Gasket assures water-tight and dust-tight seal
  • Polyester mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Scratch-resistant polycarbonate windows are permanently bonded in place
  • Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
  • Removable hinged cover attached to body with Type 316 stainless steel hinge pin
  • Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
  • Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
  • Hinge pin and bail are corrosion-resistant Type 316 stainless steel

Specifications

Aluminum Panel
A6P6AL
Application
Controls and Drives;Corrosive Environments
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Cover Style
Solid
Depth
4
Depth
102 mm
Finish
Smooth Matte
Height
152 mm
Height
6 IN
IP Rating
IP66
Latch Type
Quick Release
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
6.94 x 4.00 in
Mounting Type
Pre-drilled mounting holes
NEMA Rating
4X
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
Overall Dimensions
114 x 88 mm
Overall Dimensions
6.50 x 6.50 in
Panel Size
124 x 124 mm
Panel Size
4.88 x 4.88 in
Protection Rating
NEMA Type 12
Series
A664CH
Size
6.00x6.00x4.00 in
Size
6x6x4
Steel Panel
A6P6
Thickness
0.14 in
Thickness
51.40mm (2.024")
Type
Solid Cover, Quick Release
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
2.3 lb
Width
152 mm
Width
6 IN
Package Dimensions (L x W x H)
9.3 IN x 9.2 IN x 6.9 IN
Package Dimensions (L x W x H)
23.622 cm x 23.368 cm x 17.526 cm
Package Weight (Imperial)
2.300 L
Package Weight (Metric)
1.043 kg
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
1/2 Inch, 90 Degree, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN20DA

1/2 Inch, 90 Degree, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A664CHQRFG Controller

This guide provides step-by-step instructions for installing and configuring the A664CHQRFG controller, ensuring proper wiring and setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A664CHQRFG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and input/output wires to the appropriate terminals on the controller. Ensure all connections are secure and insulated.

  3. Ground the equipment

    Connect a grounding wire to the grounding terminal of the controller and ensure it is properly grounded according to the National Electrical Code.

  4. Power on the controller

    Turn on the power supply to the controller and verify that the power indicator is lit. Use a multimeter to check the voltage at the terminals.

  5. Configure the controller settings

    Access the controller's configuration interface and set the necessary parameters according to your application requirements.

  6. Calibrate the controller

    Follow the calibration procedure as outlined in the user manual to ensure accurate operation of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.