nVent A62H48CLP - Two-Door with Floorstand Type 4, 62.06x48.06x10.06, Gray, Steel
nVent

A62H48CLP

UPC: 783510264000


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Type 4 Enclosure (SKU: A62H48CLP) is a robust, corrosion-resistant industrial housing designed to safeguard critical control systems, instrumentation, and electrical components in demanding environments. Engineered for outdoor deployment and food processing facilities, this enclosure delivers superior protection against wet, non-corrosive conditions while maintaining operational integrity. Constructed from high-grade steel with a durable polyester powder coating, the A62H48CLP meets Type 4 environmental ratings, ensuring resistance to dust, water ingress, and moderate mechanical impacts. Its gray finish provides both aesthetic consistency and enhanced UV resistance, making it ideal for applications where long-term durability and visual appeal are priorities. Key features of the nVent Type 4 Enclosure include a continuous stainless steel hinge paired with secure clamp mechanisms for effortless access and tamper resistance. The integrated floor stand elevates the unit to facilitate under-enclosure cleaning and cable management, while also improving airflow around mounted equipment. This design accommodates versatile mounting configurations—whether on removable panels or rack systems—allowing for flexible internal layout adjustments to suit specific operational needs. The enclosure’s 62.06 x 48.06 x 10.06-inch dimensions provide ample interior space for housing PLCs, HMIs, variable frequency drives, and other automation hardware, with additional room for future expansions or modifications. Industries that benefit from the A62H48CLP include food and beverage processing, where NEMA Type 4 compliance is critical for washdown environments and hygiene compliance. It is equally suited for outdoor utility installations, wastewater treatment plants, and manufacturing facilities where exposure to moisture, humidity, or corrosive atmospheres is a concern. The enclosure’s powder-coated finish resists chemical degradation and simplifies maintenance, reducing lifecycle costs associated with repainting or replacement. For professionals specifying enclosures, the Type 4 rating ensures compliance with IEC 60529 and NEMA 250 standards, providing peace of mind in regulated or audited environments. Installation is streamlined thanks to pre-drilled mounting holes and removable side panels, enabling quick integration into existing infrastructure. The floor stand not only enhances stability but also allows for leveling adjustments on uneven surfaces, a common requirement in industrial settings. nVent’s reputation for engineering reliable thermal management solutions extends to this enclosure, where airflow considerations are addressed through strategic venting options and optional accessory kits. Trusted by engineers and facility managers worldwide, nVent’s Type 4 enclosures are a cornerstone of protection in industries where equipment reliability directly impacts productivity and safety. Whether deployed in a food processing plant, a solar farm inverter station, or a municipal water treatment facility, the A62H48CLP delivers uncompromising performance where it matters most.
  • Seams continuously welded and ground smooth
  • Body stiffeners for added strength
  • Removable centerpost permits easy panel installation
  • Panel supports
  • Return flange around three sides of door and along top of enclosure opening channels away liquids and contaminants
  • Stainless steel door clamps on three sides of each door assure water-tight seal
  • Heavy gauge continuous hinge with stainless steel hinge pin
  • Hasp and staple for padlock
  • Data pocket is high-impact thermoplastic
  • 12-in. floor stands bolted-on to enclosure

Specifications

Application
Controls and Drives;Power Distribution
Body Stiffener
0
Body Stiffener
381 mm
Body Stiffener
15 in
Clamp Quantity
16
Color
Gray
Color Code
ANSI 61
Conductive Panel
A60P48G
Depth
256 mm
Depth
10.06 in
Finish
Powder Coated
Height
62.06
Height
1,576
Height
1,576 mm
IP Rating
IP66
Material
Steel
Modification Services
Yes
Mounting Type
Floorstand
NEMA Rating
4
Nema Rating
Type 4
NEMA Rating
4 Watertight
Panel
A60P48
Panel Size
381 mm
Panel Size
15 in
Protection Rating
NEMA Type 12
Series
nVent Type 4 Enclosure
Size
62.06x48.06x10.06in
Size
62.06x48.06x10.06 in
Thickness
51.40mm (2.024")
Thickness
2.66 mm
Thickness
12 ga
Type
Mild Steel Freestanding Industrial Enclosures
Type Number
Type 4
Weight
392 lb
Width
1,221 mm
Width
48.06
Width
1,221
Package Dimensions (L x W x H)
56 IN x 30 IN x 85 IN
Package Dimensions (L x W x H)
142.24 cm x 76.2 cm x 215.9 cm
Package Weight (Imperial)
392.000 L
Package Weight (Metric)
177.811 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A24R208NK Controller

This guide provides step-by-step instructions for installing and configuring the A24R208NK Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A24R208NK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage as specified in the manual.

  4. Configure the controller settings

    Access the controller's configuration menu using the interface. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.