Authorized nVent Distributor
nVent A60X1E4008 - Low-Profile 1-Door Disconnect Type 12, 60.00x40.25x8.00, Gray, Steel

nVent A60X1E4008 Low-Profile 1-Door Disconnect Type 12, 60.00x40.25x8.00, Gray, Steel

UPC: 783510127374


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A60X1E4008 is a low-profile, single-door Type 12 disconnect enclosure designed for free-standing applications in industrial environments. It features a single hinged door with a mechanical interlock system that requires the master door to be opened first, ensuring a sequential access protocol that prevents unauthorized entry to slave doors. The enclosure includes an oil-resistant gasket for protection against dust, dirt, and falling debris, meeting NEMA Type 12 standards for indoor use in industrial settings. A preferred cutout on the right flange accommodates most disconnect switches and circuit breakers, simplifying installation and integration with existing systems. The interior is painted white for improved visibility and organization of components, while lifting eyes are integrated for safe handling during installation. This model is designed for reliable equipment protection and organized electrical distribution in demanding industrial environments.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy duty lifting eyes anchor into reinforced top on larger models
  • Removable centerposts for easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy duty latch mechanism operated by zinc die-cast padlocking defeater handle on all doors; 2-point latch on enclosures up to 36 in. (914 mm); 3-point latch on enclosures 42 in. (1067 mm) and above
  • Oil-resistant gasket
  • Removable .127-in. thick steel panels mount on collar studs
  • Master door is far right-hand door on all enclosures

Specifications

Application
Power Distribution; Controls and Drives; Arc Flash Safety
Application
Arc Flash Safety;Controls and Drives;Power Distribution
Color
Gray
Color
Grey
Color Code
ANSI 61
Conductive Panel
A54P33G
Depth
8 in
Depth
203 mm
Depth
8 mm
Finish
Powder Coated
Height
60 in
Height
1,524 mm
IP Rating
IP55
Lifting Eye Quantity
2
Lifting Eyes
2
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
Wall-mount or Free-stand
Nema Rating
Type 12
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel
A54P33
Panel Quantity
1
Protection Rating
NEMA Type 12
Size
60.00x40.25x8.00
Size
60.00x40.25x8.00 in
Thickness
51.40mm (2.024")
Thickness
2.48973 mm
Thickness
0.098 in
Type
Mild Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 12
Weight
286 lb
Width
40.25 in
Width
1,022 mm
Width
1,022
Package Dimensions (L x W x H)
40.25 IN x 8 IN x 48 IN
Package Dimensions (L x W x H)
102.235 cm x 20.32 cm x 121.92 cm
Package Weight (Imperial)
286.000 L
Package Weight (Metric)
129.730 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A60X1E4008 Disconnect Enclosure

This guide provides step-by-step instructions for installing the A60X1E4008 Disconnect Enclosure, including mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Watertight conduit hubs

  1. Mount the enclosure

    Secure the A60X1E4008 Disconnect Enclosure to a stable surface using the provided mounting screws. Ensure the enclosure is level and firmly attached.

  2. Install conduit hubs

    Use a hole saw to cut the required openings for the conduit hubs according to the specifications. Install the watertight conduit hubs as per the manufacturer's instructions.

  3. Connect wiring

    Strip the ends of the wires and connect them to the terminal connectors inside the enclosure. Ensure all connections are secure and properly insulated.

  4. Verify connections

    Use a multimeter to check the continuity of the connections and ensure there are no short circuits. Double-check that all wiring complies with local electrical codes.

  5. Adjust door catch

    Fasten the door catch to the bracket inside the enclosure door. Adjust the door catch according to the disconnect manufacturer's instructions to ensure proper operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.