nVent A60CPX4812SSLPN4 - Floor-Mount Disconnect 2-Door Center 3pt Latch Type 4X, 60x48x12, Brushed, SS304
nVent

A60CPX4812SSLPN4

UPC: 783510111083


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A60CPX4812SSLPN4 is a Type 4X floor-mount disconnect enclosure constructed from SS304 stainless steel, designed for harsh industrial environments. Measuring 60 inches high, 48 inches wide, and 12 inches deep, this enclosure provides ample space for housing disconnect switches, circuit breakers, and other electrical components. It features a 2-door design with a 3-point latching system for a secure seal, ensuring protection against water ingress and dust. The enclosure meets Type 4X and IP66 ratings, making it ideal for washdown areas, corrosive atmospheres, and outdoor installations. Certified to UL508A and cUL standards, it complies with stringent industry safety requirements. The brushed SS304 finish resists corrosion and requires minimal maintenance, while the center door configuration allows easy access for wiring and component installation. Commonly used in food and beverage processing, water treatment, chemical industries, and other demanding applications where equipment longevity and safety are critical.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough collar excludes liquids and contaminants
  • Removable centerposts permit easy panel installation
  • Heavy-gauge continuous hinges
  • Heavy-duty lifting eyes are Type 316 stainless steel
  • Data pocket is high-impact thermoplastic
  • 15-inch floor stands are welded to enclosure
  • Seamless foam-in-place gasket provides oil-tight and dust-tight seal against contaminants
  • Panel supports

Specifications

Application
Arc Flash Safety;Controls and Drives;Corrosive Environments
Color
Brushed
Color
Unpainted
Conductive Panel
A60P48G
Depth
308 mm
Depth
12.12
Depth
308
Finish
Brushed #4
Height
1,527 mm
Height
60.12
Height
1,527
IP Rating
IP66
Material
SS304 Stainless Steel
Material
SS304
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
Mounting Type
Floor-Mount
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Panel
A60P48
Panel Size
1422 x 1118 mm
Panel Size
56.00 x 44.00 in
Protection Rating
NEMA Type 12
Series
A60CPX
Series
nVent A60CPX4812SSLPN4
Size
60x48x12 inches
Size
60.12x48.50x12.12 in
Size
60" H x 48" W x 12" D
Thickness
51.40mm (2.024")
Thickness
2.78 mm
Thickness
12 ga
Type
Stainless Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 3R
Weight
382 lb
Width
1,232 mm
Width
48.5
Width
1,232
Package Dimensions (L x W x H)
57 IN x 30 IN x 84 IN
Package Dimensions (L x W x H)
144.78 cm x 76.2 cm x 213.36 cm
Package Weight (Imperial)
382.000 L
Package Weight (Metric)
173.275 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A60CPX4812SSLPN4 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the A60CPX4812SSLPN4 controller.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Terminal blocks

  1. Mount the controller

    Secure the A60CPX4812SSLPN4 controller to the designated mounting surface using appropriate screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire connectors to attach the power and signal wires to the corresponding terminals on the controller. Follow the wiring diagram provided in the manual to ensure correct connections.

  3. Configure the controller settings

    Power on the controller and use the interface to set the desired parameters. Refer to the user manual for specific configuration options and programming instructions.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the manual. Use a multimeter to verify output signals against expected values.

  5. Verify installation

    Double-check all connections and settings. Ensure that the controller operates as intended before finalizing the installation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.