nVent A602418FS - Freestand Single Access White Inside Type 12, 60.06x24.06x18.06, Gray, Steel
nVent

A602418FS

UPC: 783510250102


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A602418FS is a Type 12 freestanding enclosure designed to protect electrical and electronic components in harsh industrial environments. With dimensions of 60.06" H x 24.06" W x 18.06" D, it provides ample internal space for complex control panels, power distribution systems, and automation hardware. Certified to UL 508A, cUL (CSA C22.2 No. 94), NEMA/EEMAC Type 12, and IEC 60529 IP55 standards, this gray steel enclosure resists dust, dirt, and incidental contact. The unibody steel construction ensures structural integrity and simplifies installation, while the single-access front door enables efficient maintenance. Ideal for manufacturing, automotive, food processing, and water/wastewater applications, this US-made enclosure supports flexible internal mounting configurations for PLCs, HMIs, power supplies, and terminal blocks. Key features include: * UL 508A Listed; Type 12; File No. E61997 * cUL Listed per CSA C22.2 No. 94; Type 12; File No. E61997 * NEMA/EEMAC Type 12 * IEC 60529, IP55 * Seismic accessories available * OSHPD Pre-Approval OPM-0247-13
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Stiffeners on back of two-door enclosures maintain flatness and increase rigidity
  • Lifting eyes for easy handling
  • 3-point latches operated by oil-tight key-locking handle
  • Concealed, easy-to-remove hinges
  • Data pockets are high-impact thermoplastic
  • Internal mounting channels welded horizontally to sides at top, bottom and center
  • Optional panels and rack mount angles can be mounted anywhere along channels
  • Oil-resistant door gasket
  • Bonding provision on door

Specifications

Application
Controls and Drives;Power Distribution
Color
Gray
Color Code
ANSI 61
Depth
18.06
Depth
459
Depth
459 mm
Finish
Powder Coated
Height
60.06
Height
1,526
Height
1,526 mm
Interior Color
White
IP Rating
IP55
Lifting Eye Quantity
2
Material
Steel
Material
Mild Steel
Modification Services
Yes
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Protection Rating
NEMA Type 12
Rack Unit Quantity
28
Size
60.06x24.06x18.06 in
Thickness
51.40mm (2.024")
Thickness
2.66 mm
Thickness
12 ga
Type
Mild Steel Freestanding Industrial Enclosures
Type Number
Type 12
Weight
234 lb
Width
611 mm
Width
24.06
Width
611
Package Dimensions (L x W x H)
36 IN x 30 IN x 69 IN
Package Dimensions (L x W x H)
91.44 cm x 76.2 cm x 175.26 cm
Package Weight (Imperial)
234.000 L
Package Weight (Metric)
106.142 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A24R208NK Controller

This guide provides step-by-step instructions for installing and configuring the A24R208NK Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A24R208NK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage as specified in the manual.

  4. Configure the controller settings

    Access the controller's configuration menu using the interface. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.