Overview

The nVent A48X3E11912 is a low-profile, Type 12 disconnect enclosure designed for indoor industrial applications. Constructed from durable steel with a gray finish, this enclosure measures 48.00" H x 118.25" W x 12.00" D. Its three-door configuration provides enhanced accessibility for installation and maintenance, accommodating complex electrical systems and disconnect switches. The enclosure features a Type 12 rating, offering protection against dust, dirt, and water ingress. Key specifications include a body thickness of .098 inches. Collar studs are included for mounting optional panels, and holes are provided for disconnect operating handles and hardware. The data pocket is made of high-impact thermoplastic. This enclosure is suitable for panel builders and system integrators in sectors such as manufacturing, automation, and power distribution, ensuring the reliability of critical electrical components. Manufactured in the US, it is backed by nVent's expertise. Compatible panels include A42P33, A42P33G, A42P72, and A42P72G. It is designed for free-standing installation.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy duty lifting eyes anchor into reinforced top on larger models
  • Removable centerposts for easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy duty latch mechanism operated by zinc die-cast padlocking defeater handle on all doors; 2-point latch on enclosures up to 36 in. (914 mm); 3-point latch on enclosures 42 in. (1067 mm) and above
  • Oil-resistant gasket
  • Removable .127-in. thick steel panels mount on collar studs
  • Master door is far right-hand door on all enclosures

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Arc Flash Safety; Power Distribution; Controls and Drives
Body Stiffener
3
Color
Gray
Color Code
ANSI 61
Conductive Panel
A42P33G, A42P72G
Depth
12
Depth
305 mm
Finish
Powder Coated
Height
48 in
Height
1,219 mm
IP Rating
IP55
Lifting Eye Quantity
2
Lifting Eyes
2
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
Wall-mount or Free-stand
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Panel
A42P33, A42P72
Panel Quantity
1
Panel Quantity
1, 1
Protection Rating
NEMA Type 12
Size
48.00x118.25x12.00
Size
48.00x118.25x12.00 in
Thickness
51.40mm (2.024")
Thickness
2.48973 mm
Thickness
0.098 in
Type
Mild Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 12
Weight
747 lb
Width
118.25
Width
3,004
Width
3,004 mm
Package Dimensions (L x W x H)
120 IN x 36 IN x 45 IN
Package Dimensions (L x W x H)
304.8 cm x 91.44 cm x 114.3 cm
Package Weight (Imperial)
747.000 L
Package Weight (Metric)
338.839 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A48X3E11912 Disconnect Enclosure

This guide provides step-by-step instructions for installing the A48X3E11912 Disconnect Enclosure, including mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Hole saw, Punch tool, Multimeter

Supplies needed:

Mounting screws, Watertight conduit hubs, Lockwashers

  1. Prepare the installation site

    Ensure the installation area is clean and free of obstructions. Verify that the mounting surface is level and capable of supporting the enclosure.

  2. Mount the enclosure

    Secure the enclosure to the mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  3. Install conduit hubs

    Use a hole saw or punch tool to cut openings for the conduit hubs as per the recommended sizes. Install the watertight conduit hubs according to the manufacturer's instructions.

  4. Connect wiring

    Run the electrical wiring through the installed conduit hubs. Use terminal connectors to secure the wiring to the appropriate terminals inside the enclosure.

  5. Verify connections

    Use a multimeter to check all electrical connections for continuity and proper voltage levels before powering on the system.

  6. Adjust door catch

    Fasten the door catch to the bracket inside the enclosure door, following the manufacturer's instructions to ensure proper alignment with the disconnect operating handle.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.