Authorized nVent Distributor
nVent A48R3612HCR - Medium Drip-Shield Hinged-Cover Type 3R, 48.00x36.00x12.00, Gray, Steel

nVent A48R3612HCR Medium Drip-Shield Hinged-Cover Type 3R, 48.00x36.00x12.00, Gray, Steel

UPC: 783510427504


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Its robust construction ensures protection for internal components. Designed to meet basic functionality requirements, it provides protection against rain, sleet, and snow, making it ideal for outdoor horizontal mounting applications such as junction or pull boxes. Key features include a drip shield top and seam-free sides, front, and back for enhanced weather resistance. This enclosure adheres to industry standards, being UL 50, 50E Listed (Type 3R), cUL Listed per CSA C22.2 No 94 (Type 3R), NEMA/EEMAC Type 3R, and IEC 60529, IP32 rated. Collar studs are provided for mounting optional panels, and a hasp and staple are included for padlocking. Panels are sold separately. SKU: A48R3612HCR. Country of Origin: US.
  • Drip shield top and seam-free sides, front, and back protect from rain, snow, or sleet
  • 16-gauge plated steel continuous hinge has stainless steel pin
  • Cover fastened securely with captive plated steel screws
  • Collar studs provided for mounting optional panels
  • Hasp and staple provided for padlocking
  • No gasketing or knockouts
  • Enclosures are finished with paint over plated surfaces

Specifications

Aluminum Panel
A48P36AL
Application
Controls and Drives;Power Distribution
Body Thickness
1.9 mm
Body Thickness
16 ga
Body Thickness
14 ga
Color
Gray
Color
Grey
Color Code
ANSI 61
Depth
305 mm
Depth
12 in
Door Thickness
1.9 mm
Door Thickness
14 ga
Finish
Galvanized
Height
1,219 mm
Height
48 in
IP Rating
IP32
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
49.00 x 27.00 in
Mounting Type
Outdoor Horizontal Mounting
NEMA Rating
3r
NEMA Rating
3R Weather-resistant, except dust
NEMA Rating
Type 3R
Overall Length
3.3 in
Overall Length
1,270 mm
Overall Length
50 in
Panel
A48P36
Panel Size
1143 x 838 mm
Panel Size
45.00 x 33.00 in
Protection Rating
NEMA Type 3R
Size
48.00x36.00x12.00 in
Size
48.00x36.00x12.00 inches
Type
Wall-Mounted / Pad-Mounted Enclosures
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 3R
Weight
142 lb
Width
914 mm
Width
36 in
Package Dimensions (L x W x H)
52.75 IN x 37 IN x 13.25 IN
Package Dimensions (L x W x H)
133.985 cm x 93.98 cm x 33.655 cm
Package Weight (Imperial)
142.000 L
Package Weight (Metric)
64.411 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
94 CFM Filter Fan, 115V N12 - Lt. Gray

PF42500T12LG

94 CFM Filter Fan, 115V N12 - Lt. Gray
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install Conduit Entry into A48R3612HCR Enclosures

Instructions for installing conduit entry into nVent Hoffman rainproof enclosures.

Estimated time: 30m

Tools needed:

Drill, Punch, Screwdriver

Supplies needed:

U.L. listed rain tight or liquid tight conduit hubs, Conduit, Locknuts, Locking bushing

  1. Determine Conduit Entry Location

    Decide whether the conduit entry will be above or below live parts. Refer to the document for specific requirements for each scenario.

  2. Install Conduit Hubs (If Applicable)

    If conduit entry is above live parts, use only U.L. listed rain tight or liquid tight conduit hubs. Install the hubs and conduit according to the hub manufacturer's instructions.

  3. Prepare Enclosure for Conduit

    If conduit entry is below live parts, punch or drill the correct size hole for the conduit to be used, or use the appropriate knockout if provided. Refer to the table for correct hole sizes based on conduit size.

  4. Secure the Conduit

    Secure the conduit using locknuts inside and out, or by using a locking bushing on the inside and a locknut on the outside. Ensure a tight and secure fit.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.