Overview

The nVent **Type 4 Continuous Hinge Enclosure with Clamps (LP Series)** (SKU: A48H36DLP) is a rugged, single-door industrial enclosure designed for demanding indoor and outdoor applications where environmental protection and security are critical. Engineered with a continuous hinge and three-sided clamp system, this enclosure ensures a tight, tamper-resistant seal that meets **NEMA Type 4** and **IP Type 4** standards, providing reliable defense against dust, water, and corrosion. Constructed from **mild steel** with a **gray polyester powder finish** applied both inside and out, the enclosure delivers exceptional durability and long-term performance in harsh conditions, including coastal, industrial, or high-moisture environments. This enclosure’s **48x36x12-inch** dimensions offer ample internal space for housing sensitive electrical components, control panels, or automation systems while maintaining a compact footprint for efficient installation. The **continuous hinge design** eliminates the weak points of traditional hinges, reducing wear and tear over time and ensuring smooth, reliable operation even after repeated use. The **three-sided clamp system** creates a uniform seal around the door, preventing ingress of contaminants and maintaining the enclosure’s protective integrity. Unlike standard enclosures, this model’s **powder-coated finish** provides superior corrosion resistance, making it ideal for outdoor installations or facilities exposed to chemicals, humidity, or temperature fluctuations. Professionals across industries such as **manufacturing, utilities, telecommunications, and transportation** rely on nVent enclosures to safeguard critical infrastructure. The **Type 4 rating** confirms compliance with stringent safety and protection standards, ensuring peace of mind in applications where equipment failure could lead to costly downtime or safety hazards. Installation is straightforward, with pre-drilled mounting holes and compatibility with standard hardware, allowing for quick integration into existing systems. nVent’s reputation for engineering high-performance electrical and thermal management solutions further reinforces the reliability of this enclosure, as it is backed by decades of innovation and a global network of industry expertise. Key advantages of the **nVent A48H36DLP** include: - **Superior environmental protection** with NEMA Type 4/IP Type 4 compliance for outdoor and indoor use. - **Enhanced durability** from mild steel construction and gray polyester powder coating, resisting rust, UV exposure, and chemical corrosion. - **Secure, tamper-resistant design** via continuous hinge and three-sided clamps, preventing unauthorized access. - **Space-efficient yet spacious** 48x36x12-inch interior accommodates large components while optimizing floor or wall space. - **Easy maintenance and installation** with pre-drilled holes and a robust, field-proven design. Whether protecting PLCs in a factory, telecom equipment in a remote site, or control panels in a wastewater treatment plant, the **nVent Type 4 Continuous Hinge Enclosure with Clamps** delivers unmatched protection and longevity. Trusted by engineers and facility managers worldwide, this enclosure exemplifies nVent’s commitment to delivering **high-performance, application-specific solutions** that meet the rigorous demands of modern industrial environments.
  • NEMA Type 4 & IP Type 4 rated for superior environmental protection
  • Continuous hinge with three-sided clamps for secure, tamper-resistant seal
  • 48x36x12-inch mild steel enclosure with gray polyester powder finish
  • Ideal for outdoor, coastal, or high-moisture industrial applications
  • Pre-drilled mounting holes for easy installation and maintenance
  • Removable door with continuous hinge for strength and ruggedness
  • Hasp and staple provided for padlocking
  • Data pocket is high-impact thermoplastic
  • Collar studs for mounting optional panels
  • Bonding provision on door

Specifications

Application
Controls and Drives
Clamp Quantity
8
Color
Gray
Color Code
ANSI 61
Conductive Panel
A48P36G
Data Pocket
Large
Depth
12
Depth
305 mm
Finish
Powder Coated
Height
48 in
Height
1,219 mm
IP Rating
IP66
Ip Rating
IP4
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 4
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel
A48P36
Panel Size
1143 x 838 mm
Panel Size
45.00 x 33.00 in
Protection Rating
NEMA Type 12
Series
LP Series
Size
48X36X12
Size
48.00x36.00x12.00 in
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 4
Weight
136 lb
Width
914 mm
Width
36 in
Package Dimensions (L x W x H)
53 IN x 37.25 IN x 14 IN
Package Dimensions (L x W x H)
134.62 cm x 94.615 cm x 35.56 cm
Package Weight (Imperial)
136.000 L
Package Weight (Metric)
61.690 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the WS62XM6312SS Enclosure

This guide provides step-by-step instructions for mounting and wiring the WS62XM6312SS enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the WS62XM6312SS enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust door alignment

    If the enclosure is not level, place metal shims under the corners as needed to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install internal components

    Position the internal panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all components are securely fastened.

  4. Connect electrical wiring

    Use terminal connectors to wire the internal components according to the manufacturer's specifications. Verify all connections with a multimeter to ensure proper functionality.

  5. Calibrate and test

    Once all components are installed and wired, power on the enclosure and perform a functionality test to ensure everything operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.