Authorized nVent Distributor
nVent A482408LP - Continuous Hinge Enclosure with Clamps LP Type 4, 48x24x8, Gray, Mild Steel

nVent A482408LP Continuous Hinge Enclosure with Clamps LP Type 4, 48x24x8, Gray, Mild Steel

UPC: 783510283100


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A482408LP is a robust 48x24x8 inch mild steel enclosure designed for secure protection of electrical and electronic equipment in demanding indoor and outdoor environments. Constructed from 16 or 14 gauge mild steel with a durable ANSI 61 gray polyester powder coating, this enclosure meets stringent industry standards including NEMA/EEMAC Type 4, 12, and 13, and IEC 60529 IP66. Its continuous hinge and three-sided stainless steel screw-down clamp system ensure a tight, tamper-resistant seal against dust, water, and environmental contaminants. This enclosure is UL 508A Listed (File No. E61997) and cUL Listed per CSA C22.2 No. 94 (File No. E61997), and CSA certified (File No. 42184) for Type 4 and 12 applications. The mild steel construction allows for field modifications. Typical applications include control stations, water and wastewater treatment facilities, renewable energy installations, and transportation infrastructure. The enclosure features a seamless foam-in-place gasket and a hasp and staple for padlocking. Collar studs are provided for mounting optional panels.
  • Seams continuously welded and ground smooth
  • External, welded-on mounting brackets for wall-mounting
  • Formed external return flanges around all sides of enclosure opening
  • Stainless steel screw-down door clamps
  • Removable door with continuous hinge featuring heavy-gauge stainless steel hinge pin
  • Hasp and staple for padlocking
  • High-impact thermoplastic data pocket
  • Collar studs for mounting optional panels (sold separately)
  • Bonding provision on door
  • Seamless foam-in-place gasket

Specifications

Application
Controls and Drives
Clamp Quantity
3
Clamp Quantity
4
Color
Gray
Color
Grey
Color Code
ANSI 61
Conductive Panel
A48P24G
Data Pocket
Large
Depth
8 in
Depth
203 mm
Depth
8 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
48 in
Height
1,219 mm
Interior Color
White
Interior Color
Gray
Interior Color Code
ANSI 61
IP Rating
IP65
IP Rating
IP66
Material
Mild Steel
Material
Steel
Modification Services
Yes
NEMA Rating
12
Nema Rating
Type 4
NEMA Rating
12 Indoor, dust-resistant
Panel
A48P24
Panel Size
1143 x 533 mm
Panel Size
45.00 x 21.00 in
Protection Rating
NEMA Type 12
Series
LP
Size
48x24x8 inches
Size
48.00x24.00x8.00
Size
48.00x24.00x8.00 in
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
92 lb
Width
610 mm
Width
24 IN
Package Dimensions (L x W x H)
52.75 IN x 25.5 IN x 10 IN
Package Dimensions (L x W x H)
133.985 cm x 64.77 cm x 25.4 cm
Package Weight (Imperial)
92.000 L
Package Weight (Metric)
41.731 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A482408LP Enclosure

Instructions for mounting and adjusting the A482408LP enclosure, including door and panel installation.

Estimated time: 1h

Tools needed:

Screwdriver, Punch, Vibrating hammer (electric or air powered)

Supplies needed:

Fasteners, Metal shims, Hinge pin

  1. Prepare for Mounting

    Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.

  2. Mount the Enclosure

    Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.

  3. Adjust Door Closing (if necessary)

    If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.

  4. Install the Interior Panel

    When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.

  5. Remove or Invert Print Pocket

    The print pocket on the door can be inverted or removed entirely as needed.

  6. Install Hubs and Devices

    Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.