nVent A42R3012HCR - Medium Drip-Shield Hinged-Cover Type 3R, 42.00x30.00x12.00, Gray, Steel
nVent

A42R3012HCR

UPC: 783510427207


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A42R3012HCR is a medium-sized hinged-cover steel enclosure designed for outdoor industrial applications requiring Type 3R protection. Measuring 42.00" H x 30.00" W x 12.00" D, this enclosure provides ample internal space for electrical components, control systems, or instrumentation. Constructed from 16-gauge galvanized steel with ANSI 61 gray polyester powder paint finish inside and out, it delivers durable corrosion resistance and long-term performance in harsh environments. UL 50/50E and cUL listed to CSA C22.2 No. 94 for Type 3R applications, this enclosure meets NEMA/EEMAC Type 3R and IEC 60529 IP32 standards for protection against rain, sleet, snow, and dripping water. The drip-shield top and seam-free sides, front, and back prevent water ingress while the hinged cover with captive plated steel screws ensures secure access for installation and maintenance. Key features include collar studs for optional internal panel mounting, a hasp and staple for padlocking, and provisions for grounding. Designed for horizontal outdoor mounting on rooftops or pads without requiring vertical structure support, this enclosure is ideal for utilities, telecommunications, manufacturing, and infrastructure projects where reliable weatherproof protection is essential.
  • Drip shield top and seam-free sides, front, and back protect from rain, snow, or sleet
  • 16-gauge plated steel continuous hinge has stainless steel pin
  • Cover fastened securely with captive plated steel screws
  • Collar studs provided for mounting optional panels
  • Hasp and staple provided for padlocking
  • No gasketing or knockouts
  • Enclosures are finished with paint over plated surfaces

Specifications

Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Body Thickness
1.9 mm
Body Thickness
14 ga
Body Thickness
16 ga
Color
Gray
Color Code
ANSI 61
Depth
305 mm
Depth
12
Door Thickness
14 ga
Door Thickness
1.9 mm
Finish
Galvanized
Height
42 mm
Height
1,067 mm
IP Rating
IP32
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
43.00 x 27.00 in
Mounting Type
Hinged-Cover
NEMA Rating
3R Weather-resistant, except dust
NEMA Rating
3r
NEMA Rating
Type 3R
Overall Length
3.3 in
Overall Length
44 in
Overall Length
1,118 mm
Panel
A42P30
Panel Size
39.00 x 27.00 in
Panel Size
991 x 686 mm
Protection Rating
NEMA Type 3R
Series
nVent A42R3012HCR
Size
42.00x30.00x12.00 in
Size
42.00x30.00x12.00
Size
42.00" H x 30.00" W x 12.00" D
Type
Wall-Mounted / Pad-Mounted Enclosures
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 3R
Weight
111 lb
Width
30 IN
Width
762 mm
Package Dimensions (L x W x H)
47 IN x 31 IN x 13 IN
Package Dimensions (L x W x H)
119.38 cm x 78.74 cm x 33.02 cm
Package Weight (Imperial)
111.000 L
Package Weight (Metric)
50.350 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A24R208NK Controller

This guide provides step-by-step instructions for installing and configuring the A24R208NK Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A24R208NK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage as specified in the manual.

  4. Configure the controller settings

    Access the controller's configuration menu using the interface. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.