nVent A424212WFSSLP - Wallmount 2-Door 3-Point Latch Type 12, 42x42x12, Brushed, SS 304
nVent

A424212WFSSLP

UPC: 783510840402


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A424212WFSSLP is a Type 12 stainless steel wallmount enclosure designed for harsh indoor industrial environments. Constructed from SS 304 stainless steel, this enclosure provides superior protection against dust, dirt, and oil, making it ideal for food processing, pharmaceuticals, chemical plants, and water treatment facilities. Its 42x42x12 inch dimensions offer ample space for housing electrical and electronic components, control systems, and instrumentation. The centerpost-free interior design simplifies installation and maintenance by eliminating obstructions, reducing labor time and costs. The enclosure features overlapping doors with a seamless foam-in-place gasket for enhanced environmental sealing and security. A single key-locking handle actuates a three-point latching mechanism, ensuring a tight seal and preventing unauthorized access. Key specifications include UL 508A Listed (Type 12), cUL Listed per CSA C22.2 No 94 (Type 12), and compliance with NEMA Type 12 and IEC 60529 IP66 standards. The brushed stainless steel finish provides corrosion resistance and aesthetic appeal. Manufactured by nVent in the US, this enclosure is a reliable choice for protecting critical equipment in demanding applications.
  • 3 Point latching mechanism for simple, reliable one-motion closure
  • Seams continuously welded and ground smooth
  • Rolled lip around all sides of enclosure body opening
  • Gasketed overlapping doors eliminate need for centerpost
  • External mounting brackets
  • Plated steel 3-point latching mechanism and keylocking handle
  • Easily removable doors by pulling heavy-gauge continuous hinge pin
  • Data pocket is high-impact thermoplastic
  • Collar studs provided for mounting optional panels
  • Bonding provision on doors; grounding studs on body

Specifications

Application
Controls and Drives;Corrosive Environments
Color
Brushed
Color
Unpainted
Conductive Panel
A42P42G
Depth
12
Depth
305 mm
Finish
Brushed #4
Height
1,067 mm
Height
42 mm
IP Rating
IP55
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Wallmount 2-Door
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 12
Panel
A42P42
Panel Gauge
12
Panel Size
991 x 991 mm
Panel Size
39.00 x 39.00 in
Protection Rating
NEMA Type 12
Size
42x42x12
Size
42.00x42.00x12.00 in
Thickness
51.40mm (2.024")
Thickness
14 ga
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type Number
Type 12
Weight
125 lb
Width
1,067 mm
Width
42 in
Package Dimensions (L x W x H)
48 IN x 44 IN x 14 IN
Package Dimensions (L x W x H)
121.92 cm x 111.76 cm x 35.56 cm
Package Weight (Imperial)
125.000 L
Package Weight (Metric)
56.700 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the WS62XM6312SS Enclosure

This guide provides step-by-step instructions for mounting and wiring the WS62XM6312SS enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the WS62XM6312SS enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust door alignment

    If the enclosure is not level, place metal shims under the corners as needed to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install internal components

    Position the internal panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all components are securely fastened.

  4. Connect electrical wiring

    Use terminal connectors to wire the internal components according to the manufacturer's specifications. Verify all connections with a multimeter to ensure proper functionality.

  5. Calibrate and test

    Once all components are installed and wired, power on the enclosure and perform a functionality test to ensure everything operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.