nVent A36X2E5408 - Low-Profile 2-Door Disconnect Type 12, 36.00x54.50x8.00, Gray, Steel
nVent

A36X2E5408

UPC: 783510127152


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent Type 12 SA Disc Enclosure (SKU: A36X2E5408) is a low-profile, 2-door disconnect solution designed for industrial environments requiring space-efficient component protection. This NEMA Type 12 enclosure meets UL 508A, cUL, and CSA standards, providing defense against dust, dirt, and non-corrosive liquids in indoor and outdoor applications. Constructed from .098-inch thick steel with ANSI 61 gray polyester powder paint inside and out, it ensures durability in harsh conditions. The enclosure measures 36.00" x 54.50" x 8.00" (914 x 1384 x 203 mm) and features a master door on the right with a screwdriver-operated defeater and mechanical interlock to prevent slave doors from opening first. A preferred cutout on the right flange accommodates most disconnect switches and circuit breakers. Removable .127-inch thick steel panels mount on collar studs (sold separately) and include conductive or white finishes. Typical applications include food and beverage processing, pharmaceutical production, manufacturing, water treatment, and chemical processing. Optional accessories like electric heaters, enclosure lights, and window kits enhance functionality. Made in the USA.
  • Seams continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy duty lifting eyes anchor into reinforced top on larger models
  • Removable centerposts for easy panel installation
  • Concealed, easy-to-remove hinges
  • Heavy duty latch mechanism operated by zinc die-cast padlocking defeater handle on all doors; 2-point latch on enclosures up to 36 in. (914 mm); 3-point latch on enclosures 42 in. (1067 mm) and above
  • Oil-resistant gasket
  • Removable .127-in. thick steel panels mount on collar studs
  • Master door is far right-hand door on all enclosures

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Power Distribution; Arc Flash Safety; Controls and Drives
Body Stiffener
0
Color
Gray
Color Code
ANSI 61
Conductive Panel
A31P48G
Depth
203 mm
Depth
8 mm
Finish
Powder Coated
Height
914 mm
Height
36 in
IP Rating
IP55
Material
Mild Steel
Material
Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel
A31P48
Panel Quantity
1
Protection Rating
NEMA Type 12
Size
36.00x54.50x8.00
Size
36.00x54.50x8.00 in
Thickness
51.40mm (2.024")
Thickness
2.48973 mm
Thickness
0.098 in
Type
Mild Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 12
Weight
250 lb
Width
1,384 mm
Width
54.5
Width
1,384
Package Dimensions (L x W x H)
57 IN x 48 IN x 40 IN
Package Dimensions (L x W x H)
144.78 cm x 121.92 cm x 101.6 cm
Package Weight (Imperial)
250.000 L
Package Weight (Metric)
113.400 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A36X2E5408 Disconnect Enclosure

This guide provides step-by-step instructions for installing the A36X2E5408 Disconnect Enclosure, including mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Hole saw or Greenlee-type punch

Supplies needed:

Mounting screws, Terminal connectors, Watertight conduit hubs

  1. Prepare the installation site

    Select an appropriate location for the enclosure, ensuring it is level and accessible. Clear any obstructions and ensure compliance with local regulations.

  2. Mount the enclosure

    Secure the enclosure to the wall or mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  3. Install conduit hubs

    Use a hole saw or Greenlee-type punch to cut holes for the watertight conduit hubs according to the size requirements. Install the hubs as per the manufacturer's instructions.

  4. Connect wiring

    Run the electrical wiring through the installed conduit hubs. Strip the ends of the wires and connect them to the appropriate terminals inside the enclosure, following the wiring diagram provided by the manufacturer.

  5. Verify connections

    Use a multimeter to check the connections for continuity and proper voltage. Ensure all connections are secure and insulated.

  6. Adjust door catch

    Fasten the door catch to the bracket inside the enclosure door. Adjust it according to the manufacturer's instructions to ensure proper operation.

  7. Test the installation

    Power on the system and test the functionality of the disconnect enclosure. Ensure all components operate as expected.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.