nVent A30HS2508SSLP - Wallmount Disconnect Enclosure with Clamps Type 4X, 30x25x8, Brushed, SS304
nVent

A30HS2508SSLP

UPC: 783510275303


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A30HS2508SSLP is a robust Type 4X wallmount disconnect enclosure, meticulously crafted from SS304 stainless steel with a brushed finish for enhanced corrosion resistance. This enclosure measures 30 inches in height, 25 inches in width, and 8 inches in depth, providing ample space for disconnect switches and circuit breakers. Its Type 4X rating ensures superior protection against water and dust ingress, making it ideal for demanding industrial applications such as food processing, wastewater treatment, and outdoor installations where environmental resilience is paramount. The clamp-secured door on three sides guarantees a tight seal, meeting stringent NEMA/EEMAC Type 3, 3R, 4, 4X, 12, 13 and IEC 60529, IP66 standards. This design effectively prevents the intrusion of liquids and contaminants. The enclosure features a pre-cutout designed to accept major brands of disconnect switches and circuit breakers, simplifying installation and ensuring compatibility. It is UL 508A Listed and cUL Listed, confirming its adherence to safety and performance benchmarks. Typical applications include providing safe and reliable disconnect points for industrial machinery, motor control centers, and HVAC systems, particularly in corrosive environments. Manufactured in the USA, the nVent A30HS2508SSLP offers dependable performance and longevity for critical electrical disconnect needs.
  • Seams continuously welded and ground smooth
  • External mounting brackets
  • External-formed flange around all sides of enclosure opening
  • Stainless steel door clamps on three sides of door
  • Door removed by pulling stainless steel continuous hinge pin
  • Data pocket is high-impact thermoplastic
  • Seamless foam-in-place gasket
  • Collar studs provided for mounting optional panels
  • Holes provided in body for mounting disconnect operating handle and operating mechanism
  • Bonding provision on door; ground stud on body

Specifications

Application
Arc Flash Safety;Controls and Drives;Corrosive Environments
Application
Controls and Drives; Arc Flash Safety; Corrosive Environments
Clamp Quantity
5
Color
Unpainted
Conductive Panel
A30P24G
Data Pocket Size
12.00 x 12.00 in
Depth
8 mm
Depth
203 mm
Finish
Brushed #4
Height
762 mm
Height
30 IN
IP Rating
IP66
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
NEMA Rating
4X
NEMA Rating
4X Watertight, corrosion-resistant
Panel
A30P24
Panel Size
27.00 x 21.00 in
Panel Size
686 x 533 mm
Protection Rating
NEMA Type 4X
Size
30.00x25.38x8.00 in
Stainless Steel Type
304
Thickness
51.40mm (2.024")
Thickness
1.98 mm
Thickness
14 ga
Type
Stainless Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 3R
Weight
63 lb
Width
25.38
Width
645
Width
645 mm
Package Dimensions (L x W x H)
34.75 IN x 26.75 IN x 10.25 IN
Package Dimensions (L x W x H)
88.265 cm x 67.945 cm x 26.035 cm
Package Weight (Imperial)
63.000 L
Package Weight (Metric)
28.577 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the WS62XM6312SS Enclosure

This guide provides step-by-step instructions for mounting and wiring the WS62XM6312SS enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the WS62XM6312SS enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust door alignment

    If the enclosure is not level, place metal shims under the corners as needed to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install internal components

    Position the internal panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all components are securely fastened.

  4. Connect electrical wiring

    Use terminal connectors to wire the internal components according to the manufacturer's specifications. Verify all connections with a multimeter to ensure proper functionality.

  5. Calibrate and test

    Once all components are installed and wired, power on the enclosure and perform a functionality test to ensure everything operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.