Authorized nVent Distributor
nVent A306010WFLP - Continuous Hinge 2-Door with Handle Type 12, 30.00x60.00x10.00, Gray, Steel

nVent A306010WFLP Continuous Hinge 2-Door with Handle Type 12, 30.00x60.00x10.00, Gray, Steel

UPC: 783510271602


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A306010WFLP is a robust, two-door wall-mount enclosure designed for industrial control and automation systems. It meets NEMA/EEMAC Type 12 and IEC 60529 IP55 standards, providing reliable protection against falling dirt and dripping water. The continuous hinge design ensures secure door closure. This enclosure is UL 508A Listed and cUL Listed, making it suitable for applications requiring Type 12 protection. The internal space accommodates components for power distribution units and automation systems. Manufactured in the US by nVent, the A306010WFLP offers a practical solution for environments needing dependable environmental sealing and component security. Its dimensions provide ample internal volume for component installation and maintenance.
  • Seams continuously welded and ground smooth
  • External welded-on mounting brackets for easy installation
  • External formed body flange channels away liquids
  • Gasketed overlapping doors eliminate need for center post
  • Removable door with continuous hinge
  • Oil-tight key-locking handle with 3-point latch
  • Removable heavy gauge continuous hinge pin
  • Data pocket is high-impact thermoplastic
  • Collar studs for mounting optional panels
  • Bonding provision on both doors

Specifications

Application
Controls and Drives
Color
Gray
Conductive Panel
A60P30G
Depth
10 IN
Depth
254 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
30 IN
Height
762 mm
Interior Color
White
IP Rating
IP55
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting Type
Wall-mount
NEMA Rating
12
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A60P30
Panel Gauge
12
Panel Size
57.00 x 27.00 in
Panel Size
1448 x 686 mm
Protection Rating
NEMA Type 12
Series
Type 12 Enclosure
Size
30.00x60.00x10.00 in
Size
30.00x60.00x10.00
Size
30.00x60.00x10.00 inches
Stiffener Body
0
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 12
Weight
136 lb
Width
1,524 mm
Width
60 in
Package Dimensions (L x W x H)
61 IN x 34.5 IN x 12.5 IN
Package Dimensions (L x W x H)
154.94 cm x 87.63 cm x 31.75 cm
Package Weight (Imperial)
136.000 L
Package Weight (Metric)
61.690 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A306010WFLP Enclosure

Instructions for mounting and adjusting the A306010WFLP enclosure, including door and panel installation.

Estimated time: 1h

Tools needed:

Screwdriver, Punch, Vibrating hammer (electric or air powered)

Supplies needed:

Fasteners, Metal shims, Hinge pin

  1. Prepare for Mounting

    Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.

  2. Mount the Enclosure

    Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.

  3. Adjust Door Closing (if necessary)

    If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.

  4. Install the Interior Panel

    When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.

  5. Remove or Invert Print Pocket

    The print pocket on the door can be inverted or removed entirely as needed.

  6. Install Hubs and Devices

    Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.