nVent A302408LPEMCSS - Wallmount Hinged with Clamps EMC Type 4X, 30x24x8, Brushed, SS 304
nVent

A302408LPEMCSS

UPC: 783510258993


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A302408LPEMCSS is a 30x24x8 inch wallmount hinged enclosure constructed from 14-gauge Type 304 stainless steel, designed for industrial environments requiring robust EMI shielding and environmental protection. The enclosure features a seamless foam-in-place gasket paired with a woven monel EMC mesh gasket to provide effective EMI/RFI shielding and contaminant exclusion. A rolled lip around three sides of the door enhances sealing integrity, while stainless steel clamp assemblies ensure secure closure. The continuous hinge allows for easy access, and a hasp and staple enable padlocking for added security. This enclosure meets multiple industry standards, including UL 508A Listed Type 4, 4X, 12; cUL Listed Type 4, 4X, 12; NEMA/EEMAC Type 3, 4X, 12, 13; CSA File No. 42186 Type 4, 4X, 12; and IEC 60529 IP66, making it suitable for indoor or outdoor EMC applications in corrosive environments. Ideal for industrial automation, telecommunications, oil & gas, marine, and food & beverage applications, the A302408LPEMCSS provides reliable protection for sensitive electronic components against electromagnetic interference, dust, water, and other contaminants.
  • EMC design helps contain stray electromagnetic interference (EMI) signals produced by internal components and to shield those components from external EMI/RFI interference
  • Seams continuously welded and ground smooth
  • Seamless foam-in-place gasket adjacent to woven model EMC mesh gasket
  • Rolled lip around three sides of door
  • Stainless steel door clamp assemblies
  • Hasp and staple for padlocking
  • Removable door with continuous hinge
  • Data pocket is high impact thermoplastic
  • Collar studs provided for mounting optional panels
  • Bonding provision on door; grounding stud on body

Specifications

Application
Controls and Drives;Corrosive Environments
Application
Corrosive Environments; Controls and Drives
Clamp Quantity
5
Color
Unpainted
Color
Brushed
Conductive Steel Panel
A30P24G
Data Pocket
Large
Depth
203 mm
Depth
8 mm
Finish
Brushed #4
Height
30 IN
Height
762 mm
IP Rating
IP66
Ip Rating
IP66/IP69K
Material
Type 304 Stainless Steel
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel 304
Modification Services
Yes
Mounting Type
Wallmount Hinged
Mounting Type
Wallmount Hinged with Clamps
Mounting Type
Wall Mount
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X, 12
NEMA Rating
4X
Nema Rating
Type 4X
Panel Size
27.00 x 21.00 in
Panel Size
686 x 533 mm
Protection Rating
NEMA Type 12
Series
nVent A302408LPEMCSS
Size
30.00x24.00x8.00 in
Size
30X24X8
Size
30x24x8 inches
Size
30x24x8 inch
Thickness
1.98 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type Number
Type 4X
Weight
59 lb
Width
610 mm
Width
24 IN
Package Dimensions (L x W x H)
35 IN x 25.25 IN x 10 IN
Package Dimensions (L x W x H)
88.9 cm x 64.135 cm x 25.4 cm
Package Weight (Imperial)
59.000 L
Package Weight (Metric)
26.762 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the WS62XM6312SS Enclosure

This guide provides step-by-step instructions for mounting and wiring the WS62XM6312SS enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the WS62XM6312SS enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust door alignment

    If the enclosure is not level, place metal shims under the corners as needed to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install internal components

    Position the internal panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all components are securely fastened.

  4. Connect electrical wiring

    Use terminal connectors to wire the internal components according to the manufacturer's specifications. Verify all connections with a multimeter to ensure proper functionality.

  5. Calibrate and test

    Once all components are installed and wired, power on the enclosure and perform a functionality test to ensure everything operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.