nVent A24R2410HCR - Medium Drip-Shield Hinged-Cover Type 3R, 24.00x24.00x10.00, Gray, Steel

nVent A24R2410HCR Medium Drip-Shield Hinged-Cover Type 3R, 24.00x24.00x10.00, Gray, Steel

UPC: 783510492793


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A24R2410HCR is a medium-sized Type 3R drip-shield hinged-cover enclosure designed for outdoor electrical protection. Constructed from durable gray steel, this 24.00 x 24.00 x 10.00 inch enclosure provides reliable defense against falling dirt and dripping water, making it suitable for harsh environmental conditions. The hinged cover allows quick access for installation, maintenance, and troubleshooting while maintaining secure environmental protection. The enclosure features collar studs for optional internal panel mounting, enabling organized equipment layout and custom configurations. It includes compatibility with padlocks for enhanced security against unauthorized access. Common applications include housing control panels for HVAC systems, outdoor lighting controls, communication equipment, and power distribution units in utilities, telecommunications, manufacturing, and infrastructure sectors. The Type 3R rating ensures suitability for outdoor use where protection from dripping water and falling dirt is required.
  • Drip shield top and seam-free sides, front, and back protect from rain, snow, or sleet
  • 16-gauge plated steel continuous hinge has stainless steel pin
  • Cover fastened securely with captive plated steel screws
  • Collar studs provided for mounting optional panels
  • Hasp and staple provided for padlocking
  • No gasketing or knockouts
  • Enclosures are finished with paint over plated surfaces

Specifications

Aluminum Panel
A24P24AL
Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Body Thickness
1.9 mm
Body Thickness
14 ga
Body Thickness
16 ga
Color
Gray
Color
Grey
Color Code
ANSI 61
Depth
10 IN
Depth
254 mm
Door Thickness
1.9 mm
Door Thickness
14 ga
Finish
Galvanized
Height
610 mm
Height
24 in
IP Rating
IP32
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
25.00 x 13.00 in
Mounting Type
Hinged-Cover
NEMA Rating
Type 3R
NEMA Rating
3r
NEMA Rating
3R Weather-resistant, except dust
Overall Length
660 mm
Overall Length
26 IN
Overall Length
3.3 in
Panel
A24P24
Panel Size
533 x 533 mm
Panel Size
21.00 x 21.00 in
Perforated Panel
A24P24PP
Protection Rating
NEMA Type 3R
Series
nVent A24R2410HCR
Size
24.00x24.00x10.00 in
Size
24.00x24.00x10.00 In.
Type
Wall-Mounted / Pad-Mounted Enclosures
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 3R
Weight
55 lb
Width
610 mm
Width
24 IN
Package Dimensions (L x W x H)
24 IN x 24 IN x 10 IN
Package Dimensions (L x W x H)
60.96 cm x 60.96 cm x 25.4 cm
Package Weight (Imperial)
23.000 L
Package Weight (Metric)
10.433 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install Conduit Entry into A24R2410HCR Enclosures

Instructions for installing conduit entry into nVent Hoffman rainproof enclosures.

Estimated time: 30m

Tools needed:

Drill, Punch, Screwdriver

Supplies needed:

U.L. listed rain tight or liquid tight conduit hubs, Conduit, Locknuts, Locking bushing

  1. Determine Conduit Entry Location

    Decide whether the conduit entry will be above or below live parts. Refer to the document for specific requirements for each scenario.

  2. Install Conduit Hubs (If Applicable)

    If conduit entry is above live parts, use only U.L. listed rain tight or liquid tight conduit hubs. Install the hubs and conduit according to the hub manufacturer's instructions.

  3. Prepare Enclosure for Conduit

    If conduit entry is below live parts, punch or drill the correct size hole for the conduit to be used, or use the appropriate knockout if provided. Refer to the table for correct hole sizes based on conduit size.

  4. Secure the Conduit

    Secure the conduit using locknuts inside and out, or by using a locking bushing on the inside and a locknut on the outside. Ensure a tight and secure fit.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.