Authorized nVent Distributor
nVent A24N246LP - Hinged-Cover with Recessed Handle Type 1, 24.00x24.00x6.62, Gray, Steel

nVent A24N246LP Hinged-Cover with Recessed Handle Type 1, 24.00x24.00x6.62, Gray, Steel

UPC: 783510799601


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The **nVent Type 1 Enclosure (SKU: A24N246LP)** is a robust, medium-duty industrial housing designed to protect electrical controls, instrumentation, and sensitive equipment in demanding environments. Engineered with a **hinged-cover and recessed T-handle**, this enclosure ensures secure access while maintaining a clean, professional appearance. Constructed from **high-grade steel** and finished in a durable gray coating, the A24N246LP meets **Type 1** standards for indoor use, providing reliable defense against dust, dirt, and incidental contact. Trusted by professionals across industries, this enclosure is ideal for applications where **ease of access, durability, and compliance** are critical. This enclosure is part of nVent’s **CADDY®** product line, a brand synonymous with innovation and reliability in electrical and industrial solutions. The **24.00 x 24.00 x 6.62-inch** dimensions offer ample internal space for organizing wiring, circuit breakers, relays, and other components, while the **recessed handle** minimizes the risk of accidental openings or tampering—a key consideration in high-traffic or safety-sensitive areas. The **hinged cover** allows for quick inspections and maintenance without the need for complete disassembly, reducing downtime in critical operations. **Key applications** for the A24N246LP include: - **Industrial control panels** for manufacturing, automation, and robotics systems. - **HVAC and building automation** enclosures for climate control and energy management. - **Telecommunications and data centers**, where protection of sensitive electronics is paramount. - **Commercial and institutional facilities**, such as schools, hospitals, and offices, requiring NEMA Type 1-rated enclosures. - **Outdoor-adjacent indoor installations** where basic environmental protection is sufficient. Professionals choose the **nVent Type 1 Enclosure** for its **versatility, durability, and ease of installation**. The **steel construction** ensures long-term performance, while the **gray finish** resists corrosion and blends seamlessly into industrial or commercial settings. Installation is straightforward, with **pre-drilled mounting holes** and compatibility with standard hardware, making it a cost-effective solution for both new projects and retrofits. nVent’s reputation for **engineering excellence** and **customer-focused innovation** makes the A24N246LP a trusted choice for engineers, electricians, and facility managers. Whether you’re designing a new control system or upgrading existing infrastructure, this enclosure delivers the **functionality, reliability, and compliance** required for modern industrial applications. Pair it with nVent’s complementary accessories, such as gland plates or mounting brackets, to create a fully customized solution tailored to your operational needs.
  • Butt hinges on door
  • Mounting holes on back of enclosure
  • Flush cover and offset body
  • Recessed T-handle latch is flush with door
  • 16 or 14 gauge steel

Specifications

Application
Controls and Drives;Power Distribution
Color
Gray
Color
Grey
Color Code
ANSI 61
Depth
168
Depth
168 mm
Depth
6.63 in
Finish
Powder Coated
Gauge
14 ga
Height
24 in
Height
610 mm
IP Rating
IP30
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting
21.88 x 19.00 in
Mounting
Wall Mounting Brackets Available
NEMA Rating
1 Indoor, electrical protection
NEMA Rating
1
NEMA Rating
Type 1
Panel
A24N24MP
Panel Gauge
12
Panel Size
21.00 x 22.50 in
Panel Size
533 x 572 mm
Protection Rating
NEMA Type 1
Series
CADDY
Size
24.00x24.00x6.62 in
Size
24.00x24.00x6.62
Stud Quantity
4
Thickness
1.9 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Wall-Mounted / Pad-Mounted Enclosures
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 1
Weight
43 lb
Width
610 mm
Width
24 IN
Package Dimensions (L x W x H)
29.8 IN x 25 IN x 8.2 IN
Package Dimensions (L x W x H)
75.692 cm x 63.5 cm x 20.828 cm
Package Weight (Imperial)
43.000 L
Package Weight (Metric)
19.505 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A24N246LP Enclosure

Instructions for mounting and adjusting the A24N246LP enclosure, including door and panel installation.

Estimated time: 1h

Tools needed:

Screwdriver, Punch, Vibrating hammer (electric or air powered)

Supplies needed:

Fasteners, Metal shims, Hinge pin

  1. Prepare for Mounting

    Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.

  2. Mount the Enclosure

    Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.

  3. Adjust Door Closing (if necessary)

    If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.

  4. Install the Interior Panel

    When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.

  5. Remove or Invert Print Pocket

    The print pocket on the door can be inverted or removed entirely as needed.

  6. Install Hubs and Devices

    Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.