Contact for Pricing
Overview
- Fiberglass-reinforced material has excellent temperature and chemical resistance qualities and exhibits outstanding physical properties
- Type 316L stainless steel padlocking PowerGlide Handle on 3-point latch versions assures security and a water-tight seal while still allowing convenient access
- Quick-release latch versions feature fiberglass-reinforced polyester latches with integral Type 316L stainless steel padlocking hasp
- Seams are sealed; no holes or knockouts
- Gasket assures water-tight and dust-tight seal
- Fiberglass material is easily punched, drilled, filed or sawed
- Data pocket is high-impact thermoplastic
- Copper-flashed steel collar studs for mounting optional panels and terminal block kits
Specifications
Application | Controls and Drives;Corrosive Environments |
Color | Gray |
Conductive Panel | A24P20G |
Depth | 16 IN |
Depth | 406 mm |
Finish | Smooth Matte |
Height | 24.25 in |
Height | 616 mm |
IP Rating | IP66 |
Ip Rating | IP66/IP67 |
Latch Quantity | 4 |
Material | Fiberglass |
Material Quality | Fiberglass |
Modification Services | Yes |
Mounting Type | Wall-mount |
NEMA Rating | 4X |
NEMA Rating | 4X Watertight, corrosion-resistant |
Nema Rating | Type 4X |
Panel | A24P20 |
Panel Size | 21.00 x 17.00 in |
Panel Size | 533 x 432 mm |
Protection Rating | NEMA Type 12 |
Series | Quick-Release |
Size | 24.25x20.25x16.00 |
Size | 24.25x20.25x16.00 inches |
Size | 24.25x20.25x16.00 in |
Thickness | 51.40mm (2.024") |
Thickness | 0.14 in |
Type | Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures |
Type Number | Type 3R |
Weight | 36 lb |
Width | 514 mm |
Width | 20.25 |
Width | 514 |
Package Dimensions (L x W x H) | 29 IN x 23.75 IN x 20 IN |
Package Dimensions (L x W x H) | 73.66 cm x 60.325 cm x 50.8 cm |
Package Weight (Imperial) | 36.000 L |
Package Weight (Metric) | 16.330 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Install the A24H2016GQRLP Enclosure
This guide provides step-by-step instructions for installing and configuring the A24H2016GQRLP enclosure for optimal performance.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter, 7/16” wrench
Supplies needed:
Mounting screws, Terminal connectors, Shims, Sealant
- Mount the enclosure
Secure the A24H2016GQRLP enclosure to the wall using appropriate mounting screws. Ensure the surface is level and use shims if necessary to prevent sagging.
- Install conduit connections
Cut conduit holes in the ends and side walls of the enclosure as required. Use a hole saw or Greenlee-type cutter to ensure proper alignment and prevent stress on the enclosure walls.
- Wire the enclosure
Connect the internal wiring to the terminal connectors inside the enclosure. Use a multimeter to verify all connections are secure and functioning correctly.
- Seal the door hinges
Reinstall the door hinges using a 7/16” wrench and apply a high-quality sealant to maintain NEMA 4 sealing. Torque fasteners to 35 inch/pounds.
- Calibrate the enclosure
Perform any necessary calibration procedures as per the equipment specifications to ensure optimal performance of the enclosure.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.