nVent A244208WFSSLP - Wallmount 2-Door 3-Point Latch Type 12, 24x42x8, Brushed, SS 304

nVent A244208WFSSLP Wallmount 2-Door 3-Point Latch Type 12, 24x42x8, Brushed, SS 304

UPC: 783510839604


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A244208WFSSLP is a Type 12 wallmount enclosure constructed from 304 stainless steel, measuring 24 inches wide, 42 inches high, and 8 inches deep. This enclosure is designed for indoor industrial applications requiring corrosion resistance and protection against falling dirt and dripping water. It features a dual-door configuration with a centerpost-free interior, facilitating easier panel mounting and component arrangement. Security is provided by a single key-locking handle operating a three-point latching mechanism, ensuring a tight seal. The brushed stainless steel finish offers a clean aesthetic and enhanced resistance to surface scratching. This enclosure meets NEMA Type 12 and IEC 60529 IP66 standards, providing reliable protection in harsh environments. It is UL 508A Listed and cUL Listed per CSA C22.2 No 94, ensuring compliance with safety and performance requirements. The body gauge is 14, and the door gauge is 12, delivering robust construction for demanding applications. Applications include food and beverage processing, pharmaceutical manufacturing, and water treatment facilities where equipment protection is critical. The 7 latches provide secure closure, while the CP2424 panel configuration supports efficient component organization. Manufactured in the US, this enclosure is built to withstand the rigors of industrial use.
  • 3 Point latching mechanism for simple, reliable one-motion closure
  • Seams continuously welded and ground smooth
  • Rolled lip around all sides of enclosure body opening
  • Gasketed overlapping doors eliminate need for centerpost
  • External mounting brackets
  • Plated steel 3-point latching mechanism and keylocking handle
  • Easily removable doors by pulling heavy-gauge continuous hinge pin
  • Data pocket is high-impact thermoplastic
  • Collar studs provided for mounting optional panels
  • Bonding provision on doors; grounding studs on body

Specifications

Application
Corrosive Environments; Controls and Drives
Application
Controls and Drives;Corrosive Environments
Color
Unpainted
Color
Brushed
Conductive Panel
A42P24G
Depth
8 in
Depth
203 mm
Depth
8 mm
Finish
Brushed #4
Height
24 in
Height
610 mm
IP Rating
IP55
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Wallmount
Nema Rating
Type 12
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel
A42P24
Panel Gauge
12
Panel Size
39.00 x 21.00 in
Panel Size
991 x 533 mm
Protection Rating
NEMA Type 12
Size
24.00x42.00x8.00
Size
24.00x42.00x8.00 in
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Stainless Steel Wall Mounted Industrial Enclosures
Type Number
Type 12
Weight
70 lb
Width
1,067 mm
Width
42 in
Package Dimensions (L x W x H)
44 IN x 29 IN x 10 IN
Package Dimensions (L x W x H)
111.76 cm x 73.66 cm x 25.4 cm
Package Weight (Imperial)
70.000 L
Package Weight (Metric)
31.752 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A244208WFSSLP Enclosure

Instructions for mounting and adjusting the A244208WFSSLP enclosure, including door and panel installation.

Estimated time: 1h

Tools needed:

Screwdriver, Punch, Vibrating hammer (electric or air powered)

Supplies needed:

Fasteners, Metal shims, Hinge pin

  1. Prepare for Mounting

    Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.

  2. Mount the Enclosure

    Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.

  3. Adjust Door Closing (if necessary)

    If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.

  4. Install the Interior Panel

    When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.

  5. Remove or Invert Print Pocket

    The print pocket on the door can be inverted or removed entirely as needed.

  6. Install Hubs and Devices

    Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.