Authorized nVent Distributor
nVent A20R208HCLO - Drip-Shield Hinged Lift-Off Cover Type 3R, 20.00x20.00x8.00, Gray, Steel

nVent A20R208HCLO Drip-Shield Hinged Lift-Off Cover Type 3R, 20.00x20.00x8.00, Gray, Steel

UPC: 783510389406


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A20R208HCLO is a Type 3R steel enclosure designed for outdoor electrical and electronic protection. Its hinged lift-off cover features padlock pull catch latches, providing secure access while allowing easy removal for maintenance or component installation. The Type 3R rating ensures protection against falling dirt and dripping water, making it suitable for outdoor applications exposed to rain, sleet, and snow. Integrated embossed mounting holes facilitate direct mounting to walls or panels without additional hardware. This enclosure is ideal for telecommunications, utilities, industrial automation, municipalities, and renewable energy sectors. The 8-inch depth provides ample space for components, cable management, and conduit routing.
  • Drip-shield top and seam-free sides, front and back
  • Galvanized steel lift-off hinges with stainless steel pins
  • Provisions for padlocking on each draw pull catch
  • Embossed mounting holes on back of enclosure
  • Gasketing along top of door
  • No knockouts
  • Quick-release door latches
  • Enclosures are finished with paint over plated surfaces

Specifications

Application
Controls and Drives;Power Distribution
Body Thickness
1.52 mm
Body Thickness
16 ga
Bracket Width
356 mm
Bracket Width
14 in
Color
Gray
Color
Grey
Color Code
ANSI 61
Depth
203 mm
Depth
8 mm
Depth
8 in
Door Thickness
1.9 mm
Door Thickness
14 ga
Finish
Galvanized
Height
20 mm
Height
508 mm
Height
20 in
Hole Spacing, Mounting Bracket
13 mm
Hole Spacing, Mounting Bracket
330 in
IP Rating
IP32
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
21.31 in
Mounting Bracket Kit
AMFK3RLO14
NEMA Rating
3R Weather-resistant, except dust
NEMA Rating
3r
Overall Dimensions
114 x 88 mm
Overall Dimensions
22.31 x 21.25 in
Panel
A20P20
Panel Mounting Kit
APMK3RLO14
Panel Size
17.00 x 17.00 in
Panel Size
432 x 432 mm
Protection Rating
NEMA Type 3R
Size
20.00x20.00x8.00 in
Type
Mild Steel Wall Mounted Industrial Enclosures
Type
Wall-Mounted / Pad-Mounted Enclosures
Type Number
Type 3R
Weight
32 lb
Width
508 mm
Width
20 IN
Package Dimensions (L x W x H)
23.75 IN x 21.75 IN x 10 IN
Package Dimensions (L x W x H)
60.325 cm x 55.245 cm x 25.4 cm
Package Weight (Imperial)
32.000 L
Package Weight (Metric)
14.515 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Repaint a Hoffman Enclosure

Guide on preparing and repainting Hoffman enclosures with TGIC polyester powder coating.

Estimated time: 1h

Tools needed:

180 grit sandpaper, 220 or 240 grit sandpaper (optional), Solvent, Paint manufacturer's recommended tools

Supplies needed:

TGIC polyester powder coated Hoffman enclosure, Paint compatible with TGIC polyester powder coating, Primer (if recommended by paint manufacturer)

  1. Prepare the Surface

    Thoroughly sand all enclosure surfaces with 180 grit sandpaper. If sanding marks are objectionable, finish sanding with 220 or 240 grit sandpaper. Wet wipe all surfaces with a solvent to remove any possible contaminants. Consult with your paint manufacturer for proper cure time and hardness prior to testing the paint for adhesion.

  2. Select Appropriate Paint

    Choose a paint that exhibits good adhesion properties over polyester powder. Recommended types include two-component epoxies, some two-component polyurethanes, and alkyd baking enamels. If using alkyd finishes, do not bake at temperatures exceeding 150°F to avoid discoloration.

  3. Apply Paint

    Apply two or three medium to light coats of paint. Allow two to three minutes flash off between coats. Allow paint to cure adequately according to the paint manufacturer's instructions.

  4. Test Adhesion

    After the paint has cured adequately, test the paint for adhesion. Consult with your paint manufacturer for proper cure time and hardness prior to testing.

  5. Test Repainting Process

    NOTICE: Always test the repainting process on an inconspicuous area prior to full application.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.