Contact for Pricing
Overview
- Fiberglass-reinforced material has excellent temperature and chemical resistance qualities and exhibits outstanding physical properties
- Type 316L stainless steel padlocking PowerGlide Handle on 3-point latch versions assures security and a water-tight seal while still allowing convenient access
- Quick-release latch versions feature fiberglass-reinforced polyester latches with integral Type 316L stainless steel padlocking hasp
- Seams are sealed; no holes or knockouts
- Gasket assures water-tight and dust-tight seal
- Fiberglass material is easily punched, drilled, filed or sawed
- Data pocket is high-impact thermoplastic
- Copper-flashed steel collar studs for mounting optional panels and terminal block kits
Specifications
Application | Controls and Drives;Corrosive Environments |
Color | Gray |
Conductive Panel | A20P20G |
Depth | 203 mm |
Depth | 8 mm |
Finish | Smooth Matte |
Height | 513 mm |
Height | 20.19 |
IP Rating | IP66 |
Ip Rating | IP66/IP67 |
Ip Rating | IP4X |
Latch Quantity | 4 |
Material | Fiberglass |
Material Quality | Fiberglass |
Modification Services | Yes |
Mounting Type | Wall-mount |
NEMA Rating | 4X Watertight, corrosion-resistant |
NEMA Rating | 4X |
Nema Rating | Type 4X |
Panel | A20P20 |
Panel Size | 432 x 432 mm |
Panel Size | 17.00 x 17.00 in |
Protection Rating | NEMA Type 12 |
Series | nVent Hinge Cover Enclosure |
Size | 20.19x20.25x8.00 in |
Size | 20.19x20.25x8.00 |
Size | 20.19x20.25x8.00 inches |
Thickness | 51.40mm (2.024") |
Thickness | 0.14 in |
Type | Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures |
Type Number | Type 3R |
Weight | 23.7 lb |
Width | 514 mm |
Width | 20.25 |
Width | 514 |
Package Dimensions (L x W x H) | 25 IN x 24.1 IN x 12.4 IN |
Package Dimensions (L x W x H) | 63.5 cm x 61.214 cm x 31.496 cm |
Package Weight (Imperial) | 23.700 L |
Package Weight (Metric) | 10.750 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Install the A20H2008GQRLP Controller
This guide provides step-by-step instructions for installing and configuring the A20H2008GQRLP controller, ensuring proper setup and operation.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Conduit connectors
- Mount the controller
Secure the A20H2008GQRLP controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.
- Connect the wiring
Use wire strippers to prepare the wires for connection. Connect the power and signal wires to the appropriate terminals on the controller, ensuring all connections are secure and insulated.
- Configure the controller settings
Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements, and save the settings.
- Calibrate the controller
Perform a calibration procedure as specified in the user manual. This may involve adjusting settings based on feedback from connected sensors or devices.
- Verify the installation
Use a multimeter to check the voltage at the controller terminals. Ensure that all connections are functioning correctly and that the controller operates as intended.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.