The nVent Continuous Hinge Screw-Cover Enclosure (SKU: A181610CHSCFG) is a robust, Type 4X fiberglass enclosure designed for demanding industrial applications. Measuring 18x16x10 inches, this enclosure provides ample space for critical electrical components like control panels, PLCs, and circuit breakers. Constructed from high-quality fiberglass, it offers exceptional resistance to corrosion, UV degradation, and chemical exposure, making it ideal for harsh environments such as oil and gas, chemical processing, and water treatment facilities. The continuous hinge mechanism ensures a secure, tamper-resistant seal against dust and water ingress. Its screw-cover design allows for tool-free cover removal, simplifying installation and maintenance access, thereby reducing downtime. Manufactured in the US, this enclosure meets industry standards and is classified under UNSPSC code 39121324. The light gray finish enhances visibility and complements modern industrial aesthetics. Trust nVent for reliable protection of your sensitive equipment.
  • Compression-molded fiberglass has outstanding chemical- and temperature-resistance qualities and exhibits excellent weatherability and physical properties
  • Fiberglass is easily punched, drilled, filed or sawed
  • Gasket assures water-tight and dust-tight seal
  • Polyester mounting brackets and stainless steel attachment screws are provided with each enclosure
  • Scratch-resistant polycarbonate windows are permanently bonded in place
  • Molded-in-place threaded brass inserts and plated steel screws are provided for mounting optional panels and terminal block kits
  • Removable hinged cover attached to body with Type 316 stainless steel hinge pin
  • Screw-cover enclosures are secured with two captivated Type 316 stainless steel slotted cover screws
  • Enclosures with quick-release latches have corrosion-resistant polyester latches located in corners that provide unobstructed access to enclosure
  • Hinge pin and bail are corrosion-resistant Type 316 stainless steel

Specifications

Aluminum Panel
A18P16AL
Application
Corrosive Environments; Controls and Drives
Application
Controls and Drives;Corrosive Environments
Color
Gray
Color
Grey
Color
Light Gray
Color Code
RAL 7035
Cover Style
Solid Screw
Depth
10 IN
Depth
254 mm
Finish
Smooth Matte
Height
18 IN
Height
457 mm
Ip Rating
IP66/IP67
IP Rating
IP66
Material
Fiberglass
Material Quality
Fiberglass
Modification Services
Yes
Mounting
18.94 x 14.00 in
Mounting
Wall Mounting Brackets Available
Mounting Type
Wall Mount
NEMA Rating
4X Watertight, corrosion-resistant
Nema Rating
Type 4X
NEMA Rating
4X
Overall Dimensions
18.58 x 16.58 in
Overall Dimensions
114 x 88 mm
Panel Size
425 x 378 mm
Panel Size
16.75 x 14.88 in
Protection Rating
NEMA Type 12
Series
Continuous Hinge Screw-Cover Enclosure
Size
18.00x16.00x10.00 in
Size
18x16x10 inches
Steel Panel
A18P16
Thickness
0.12 in
Thickness
51.40mm (2.024")
Type
Solid Screw Cover
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Type Number
Type 13
Weight
14.8 lb
Width
406 mm
Width
16 IN
Package Dimensions (L x W x H)
20.5 IN x 18.5 IN x 12.8 IN
Package Dimensions (L x W x H)
52.07 cm x 46.99 cm x 32.512 cm
Package Weight (Imperial)
14.800 L
Package Weight (Metric)
6.713 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A181610CHSCFG Controller

This guide provides step-by-step instructions for the installation and initial setup of the A181610CHSCFG Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A181610CHSCFG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the grounding

    Connect the grounding wire to the grounding bushing inside the enclosure. Ensure that all metal portions extending out of the enclosure are properly grounded.

  3. Wire the connections

    Use terminal connectors to wire the power and signal connections to the controller. Verify that all connections are secure and correctly oriented.

  4. Power on the controller

    Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are within the specified range.

  5. Configure the settings

    Access the controller's configuration interface and set the desired parameters according to your application requirements.

  6. Calibrate the controller

    Perform any necessary calibration procedures as outlined in the user manual to ensure accurate operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.