Authorized nVent Distributor
nVent A16N166LP - Hinged-Cover with Recessed Handle Type 1, 16.00x16.00x6.62, Gray, Steel

nVent A16N166LP Hinged-Cover with Recessed Handle Type 1, 16.00x16.00x6.62, Gray, Steel

UPC: 783510798901


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A16N166LP is a robust Type 1 steel enclosure designed for basic protection of electrical and electronic controls, instrumentation, and components in indoor environments. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this enclosure offers reliable performance and durability for a wide range of industrial and commercial applications. Its 16.00x16.00x6.62 inch dimensions provide ample space for housing various control panels, junction boxes, and sensitive equipment, ensuring they are shielded from dust and accidental contact. Engineered with a focus on user convenience and operational efficiency, the A16N166LP features a hinged cover equipped with a recessed T-handle. This design not only facilitates easy access for maintenance and adjustments but also contributes to a clean, professional aesthetic while preventing accidental snagging. The gray powder-coat finish provides a durable and corrosion-resistant surface, suitable for typical indoor industrial settings. The steel construction offers inherent strength and rigidity, safeguarding the enclosed components against mechanical impacts and environmental factors within its specified rating. This Type 1 enclosure is ideal for applications where a basic level of protection against falling dirt and incidental contact is required. Common use cases include housing motor controls, HVAC system components, lighting controls, and general-purpose junction boxes in manufacturing plants, commercial buildings, and utility facilities. The straightforward design ensures straightforward installation, allowing electrical contractors and maintenance personnel to quickly integrate it into existing systems. The nVent reputation for quality manufacturing and product reliability means that users can depend on the A16N166LP to protect critical infrastructure and ensure operational continuity. Key features of the nVent A16N166LP include: * **Durable Steel Construction:** Provides robust protection for enclosed components. * **Type 1 Rating:** Offers protection against falling dirt and incidental contact in indoor environments. * **Hinged Cover with Recessed Handle:** Ensures easy access for maintenance and a streamlined appearance. * **Generous Size:** 16.00x16.00x6.62 inches offers ample internal space. * **Gray Powder-Coat Finish:** Enhances corrosion resistance and provides a professional look. When selecting enclosures for critical control systems, choosing a product from a reputable manufacturer like nVent is paramount. The A16N166LP, with its combination of practical design, durable materials, and adherence to industry standards, represents a sound investment for safeguarding your electrical installations. Its versatility and ease of use make it a go-to solution for electricians and engineers seeking dependable enclosure solutions for everyday industrial needs.
  • Butt hinges on door
  • Mounting holes on back of enclosure
  • Flush cover and offset body
  • Recessed T-handle latch is flush with door
  • 16 or 14 gauge steel

Specifications

Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Color
Gray
Color
Grey
Color Code
ANSI 61
Depth
6.63 in
Depth
168 mm
Depth
168
Finish
Powder Coated
Gauge
16 ga
Height
406 mm
Height
16 in
IP Rating
IP30
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
13.88 x 11.00 in
NEMA Rating
1 Indoor, electrical protection
NEMA Rating
1
Panel
A16N16MP
Panel Gauge
14 ga
Panel Size
330 x 368 mm
Panel Size
13.00 x 14.50 in
Protection Rating
NEMA Type 1
Size
16.00x16.00x6.62 in
Stud Quantity
4
Thickness
1.52 mm
Thickness
51.40mm (2.024")
Thickness
16 ga
Type
Wall-Mounted / Pad-Mounted Enclosures
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 1
Weight
20.4 lb
Width
406 mm
Width
16 IN
Package Dimensions (L x W x H)
21.1 IN x 17.3 IN x 8.3 IN
Package Dimensions (L x W x H)
53.594 cm x 43.942 cm x 21.082 cm
Package Weight (Imperial)
20.400 L
Package Weight (Metric)
9.253 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A16N166LP Enclosure

Instructions for mounting and adjusting the A16N166LP enclosure, including door and panel installation.

Estimated time: 1h

Tools needed:

Screwdriver, Punch, Vibrating hammer (electric or air powered)

Supplies needed:

Fasteners, Metal shims, Hinge pin

  1. Prepare for Mounting

    Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.

  2. Mount the Enclosure

    Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.

  3. Adjust Door Closing (if necessary)

    If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.

  4. Install the Interior Panel

    When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.

  5. Remove or Invert Print Pocket

    The print pocket on the door can be inverted or removed entirely as needed.

  6. Install Hubs and Devices

    Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.