nVent A16N126LP Hinged-Cover with Recessed Handle Type 1, 16.00x12.00x6.62, Gray, Steel
UPC: 783510798802
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Butt hinges on door
- Mounting holes on back of enclosure
- Flush cover and offset body
- Recessed T-handle latch is flush with door
- 16 or 14 gauge steel
Specifications
Application | Controls and Drives;Power Distribution |
Color | Gray |
Color | Grey |
Color Code | ANSI 61 |
Depth | 168 |
Depth | 6.63 in |
Depth | 168 mm |
Finish | Powder Coated |
Gauge | 16 ga |
Height | 16 in |
Height | 406 mm |
IP Rating | IP30 |
Material | Steel |
Material | Mild Steel |
Modification Services | Yes |
Mounting | 13.88 x 7.00 in |
Mounting | Wall Mounting Brackets Available |
Mounting Type | Surface or Wall Installation |
NEMA Rating | 1 |
NEMA Rating | Type 1 |
NEMA Rating | 1 Indoor, electrical protection |
Panel | A16N12MP |
Panel Gauge | 14 ga |
Panel Size | 330 x 267 mm |
Panel Size | 13.00 x 10.50 in |
Protection Rating | NEMA Type 1 |
Series | Type 1 |
Size | 16.00x12.00x6.62 in |
Size | 16.00x12.00x6.62 |
Size | 16.00x12.00x6.625 |
Stud Quantity | 4 |
Thickness | 1.52 mm |
Thickness | 16 ga |
Thickness | 51.40mm (2.024") |
Type | Wall-Mounted / Pad-Mounted Enclosures |
Type | Mild Steel Wall Mounted Industrial Enclosures |
Type Number | Type 1 |
Weight | 16.9 lb |
Width | 305 mm |
Width | 12 IN |
Package Dimensions (L x W x H) | 21.2 IN x 13.4 IN x 8.2 IN |
Package Dimensions (L x W x H) | 53.848 cm x 34.036 cm x 20.828 cm |
Package Weight (Imperial) | 16.900 L |
Package Weight (Metric) | 7.666 kg |

LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyFrequently Asked Questions
What is the material and finish of the nVent A16N126LP enclosure?
The enclosure is constructed from 16-gauge steel and features an ANSI 61 gray polyester powder paint finish.
What are the external dimensions of the nVent A16N126LP enclosure?
The external dimensions of the enclosure are 16.00 inches in height, 12.00 inches in width, and 6.00 inches in depth.
What type of protection does the nVent A16N126LP enclosure offer?
This Type 1 enclosure offers basic protection against solid objects in indoor applications where oil- or dust-tight sealing is not required.
What certifications does the nVent A16N126LP enclosure meet?
The enclosure meets UL 50, 50E, NEMA/EEMAC Type 1, and IEC 60529 IP30 standards.
How is the nVent A16N126LP enclosure mounted?
The enclosure has mounting holes on the back for installation and includes weldnuts for optional panel mounting.
What type of latch mechanism does the hinged cover have?
The hinged cover features a flush slotted latch that is operated with a screwdriver.
How to Install the A16N126LP Enclosure
Instructions for mounting and adjusting the A16N126LP enclosure, including door and panel installation.
Estimated time: 1h
Tools needed:
Screwdriver, Punch, Vibrating hammer (electric or air powered)
Supplies needed:
Fasteners, Metal shims, Hinge pin
- Prepare for Mounting
Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.
- Mount the Enclosure
Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.
- Adjust Door Closing (if necessary)
If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.
- Install the Interior Panel
When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.
- Remove or Invert Print Pocket
The print pocket on the door can be inverted or removed entirely as needed.
- Install Hubs and Devices
Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.