nVent A16H16ALP - Continuous Hinge Enclosure with Clamps LP Type 4, 16x16x6, Gray, Mild Steel
nVent

A16H16ALP

UPC: 783510242909


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent A16H16ALP Continuous Hinge Enclosure with Clamps** is a robust, Type 4-rated solution engineered for demanding indoor and outdoor electrical and electronic applications. Designed with a **16x16x6-inch** footprint and constructed from **mild steel** with a **gray polyester powder-coated finish**, this enclosure delivers superior durability, corrosion resistance, and secure protection for sensitive components in harsh environments. Backed by nVent’s reputation for industrial-grade reliability, the A16H16ALP is ideal for professionals seeking a high-performance, long-lasting enclosure for NEMA Type 4 and IP66-rated applications. This **single-door enclosure** features a **continuous hinge** and **clamps on three sides**, ensuring a tight, tamper-resistant seal that withstands dust, water, and mechanical stress. The **polyester powder finish**—applied both inside and out—provides an additional layer of protection against moisture, UV exposure, and chemical corrosion, making it a trusted choice for outdoor installations in industrial, commercial, and utility settings. Whether deployed in manufacturing plants, wastewater treatment facilities, or telecommunications infrastructure, the A16H16ALP maintains operational integrity where standard enclosures would fail. **Key Applications & Industries:** - **Industrial Automation:** Protect PLCs, HMIs, and control panels in factories, refineries, and processing plants. - **Utilities & Energy:** Safeguard electrical components in substations, solar farms, and wind turbine control systems. - **Telecommunications:** House sensitive networking equipment in outdoor cabinets or data centers. - **Transportation:** Secure signaling and control systems in rail, marine, or highway infrastructure. - **Commercial Buildings:** Manage HVAC, security, and lighting controls in exposed or high-traffic areas. **Why Choose the nVent A16H16ALP?** - **Superior Sealing:** The **three-sided clamp design** and continuous hinge eliminate gaps, preventing ingress of contaminants while resisting forced entry. - **Corrosion Resistance:** The **gray polyester powder coating** exceeds standard paint finishes, offering long-term protection in coastal, industrial, or high-humidity environments. - **Easy Installation & Maintenance:** Pre-drilled mounting holes and a **removable door** simplify access for wiring and component adjustments, reducing downtime during servicing. - **Compliance & Trust:** Certified for **NEMA Type 4** and **IP66**, the enclosure meets stringent industry standards for outdoor and indoor use, ensuring peace of mind in critical applications. - **Manufacturer Reliability:** nVent’s legacy in thermal management and electrical protection solutions guarantees engineering excellence, with products trusted by engineers and contractors worldwide. **Installation Considerations:** For optimal performance, mount the enclosure on a **flat, vibration-resistant surface** using the provided hardware. Ensure proper gasket compression during installation to maintain the **Type 4/IP66 rating**, and avoid over-tightening clamps to prevent deformation. For outdoor deployments, consider additional UV shielding or shade structures to extend the enclosure’s lifespan in extreme climates. With the **nVent A16H16ALP**, professionals gain a **cost-effective, high-durability enclosure** that balances rugged construction with ease of use—delivering reliable protection for decades in the most challenging conditions.
  • Type 4/NEMA 4 & IP66 rated for dust, water, and corrosion resistance
  • 16x16x6-inch mild steel enclosure with gray polyester powder finish
  • Continuous hinge with three-sided clamps for secure, tamper-resistant seal
  • Indoor/outdoor durability for industrial, utility, and commercial applications
  • Easy installation with pre-drilled mounting holes and removable door
  • Removable door with continuous hinge for strength and ruggedness
  • Hasp and staple provided for padlocking
  • Data pocket is high-impact thermoplastic
  • Collar studs for mounting optional panels
  • Bonding provision on door

Specifications

Application
Controls and Drives
Clamp Quantity
4
Color
Gray
Color Code
ANSI 61
Conductive Panel
A16P16G
Data Pocket
Small
Depth
152 mm
Depth
6
Depth
152
Finish
Powder Coated
Height
406 mm
Height
16 in
IP Rating
IP66
Material
Mild Steel
Material
Steel
Modification Services
Yes
Nema Rating
Type 4
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel
A16P16
Panel Size
330 x 330 mm
Panel Size
13.00 x 13.00 in
Protection Rating
NEMA Type 12
Series
A16H16ALP
Size
16.00x16.00x6.00 in
Size
16x16x6 inch
Thickness
16 ga
Thickness
51.40mm (2.024")
Thickness
1.52 mm
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 4
Weight
22 lb
Width
16 IN
Width
406 mm
Package Dimensions (L x W x H)
21 IN x 17.2 IN x 8 IN
Package Dimensions (L x W x H)
53.34 cm x 43.688 cm x 20.32 cm
Package Weight (Imperial)
22.000 L
Package Weight (Metric)
9.979 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the WS62XM6312SS Enclosure

This guide provides step-by-step instructions for mounting and wiring the WS62XM6312SS enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the WS62XM6312SS enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust door alignment

    If the enclosure is not level, place metal shims under the corners as needed to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install internal components

    Position the internal panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all components are securely fastened.

  4. Connect electrical wiring

    Use terminal connectors to wire the internal components according to the manufacturer's specifications. Verify all connections with a multimeter to ensure proper functionality.

  5. Calibrate and test

    Once all components are installed and wired, power on the enclosure and perform a functionality test to ensure everything operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.