nVent A10108CH - Continuous Hinge Enclosure Clamps CH Type 12, 10x10X8, Gray, Mild Steel
nVent

A10108CH

UPC: 783510292379


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CH Type 12 Continuous Hinge Enclosure (SKU: A10108CH) offers robust protection for sensitive electrical and electronic components in demanding industrial environments. Engineered by nVent, a trusted leader in enclosures and thermal management, this mild steel enclosure provides a secure and reliable housing solution. Its continuous hinge design facilitates easy access for maintenance, inspection, and component installation, while the integrated screw-down clamps ensure a tight and secure seal, crucial for maintaining Type 12 environmental protection ratings. This enclosure is specifically designed to shield internal equipment from dust, dirt, oil, and water, making it an ideal choice for a wide array of applications across various industries. Constructed from durable mild steel with a powder-coated gray finish, the nVent A10108CH enclosure is built to withstand harsh operating conditions. The 10x10x8 inch dimensions offer ample space for mounting control panels, power supplies, junction boxes, and other essential electrical apparatus. The continuous hinge allows for a full swing-open door, providing unobstructed access to the interior, which significantly simplifies wiring, troubleshooting, and component replacement. The robust screw-down clamp system offers a reliable and secure closure mechanism, ensuring the integrity of the seal against environmental contaminants. This design minimizes downtime and enhances operational efficiency for maintenance personnel. Typical applications for the nVent CH Type 12 Continuous Hinge Enclosure include: * **Industrial Automation:** Protecting control systems, PLCs, and human-machine interfaces (HMIs) in manufacturing plants. * **Food and Beverage Processing:** Safeguarding electrical controls in washdown environments where hygiene and protection from moisture are paramount. * **Water and Wastewater Treatment:** Housing control equipment exposed to corrosive elements and varying environmental conditions. * **Telecommunications:** Protecting sensitive networking and communication equipment in outdoor or semi-exposed locations. * **General Purpose Electrical Housing:** Providing a secure and protected space for a multitude of electrical components in commercial and industrial settings. The selection of an appropriate enclosure is critical for the longevity and reliable operation of electrical systems. The nVent CH Type 12 enclosure, with its emphasis on environmental protection and ease of access, addresses these critical needs. Professionals choose nVent for their commitment to quality, innovation, and the development of enclosures that meet stringent industry standards. The A10108CH model exemplifies this commitment, offering a dependable solution for safeguarding valuable electrical infrastructure. Its straightforward installation and maintenance procedures further contribute to its value proposition, making it a preferred choice for engineers and facility managers alike.
  • Seams continuously welded and ground smooth
  • Continuous hinge
  • Screw-down door clamps
  • Bonding provision on door
  • External wall-mounting brackets for easy installation
  • Oil-resistant gasket
  • Weldnuts provided for mounting optional panels and terminal block kits in size 6.00 x 4.00 in. (152 x 102 mm) and larger
  • Weldnuts provided for mounting optional panels and terminal block kits in size 6.00 x 4.00 in. (152 x 102 mm) and larger

Specifications

Application
Controls and Drives
Color
Gray
Color Code
ANSI 61
Conductive Panel
A10P10G
Depth
13 IN
Depth
8 in
Depth, Maximum
8
Depth, Minimum
8
Finish
Powder Coated
Height
44 IN
Height
10 IN
IP Rating
IP65
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
10.75 x 8.00 in
Nema Rating
Type 12
NEMA Rating
12
Overall Dimensions
114 x 88 mm
Overall Dimensions
11.50 x 10.94 in
Panel
A10P10
Panel Size
8.75 x 8.88 in
Panel Size
72.00 x 72.00 in
Protection Rating
NEMA Type 12
Series
CH Type 12
Size
10.00x10.00x8.00 in
Size
10x10x8
Size
10x10x8 inches
Thickness
51.40mm (2.024")
Thickness
14 ga
Type
Mild Steel Industrial Terminal and Junction Boxes
Type
Mild Steel Terminal and Junction Boxes
Type Number
Type 13
Weight
12 lb
Width
254 mm
Width
10 IN
Package Dimensions (L x W x H)
11.5 IN x 11 IN x 8.3 IN
Package Dimensions (L x W x H)
29.21 cm x 27.94 cm x 21.082 cm
Package Weight (Imperial)
12.000 L
Package Weight (Metric)
5.443 kg
Continuous Hinge Enclosure Clamps CH Type 12, 12x10x8, Gray, Mild Steel

A12108CH

Continuous Hinge Enclosure Clamps CH Type 12, 12x10x8, Gray, Mild Steel
The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

AB314

The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

How to Install the A24R208NK Controller

This guide provides step-by-step instructions for installing and configuring the A24R208NK Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the A24R208NK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Ensure that the connections are secure and insulated.

  3. Verify the connections

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage as specified in the manual.

  4. Configure the controller settings

    Access the controller's configuration menu using the interface. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the manual to ensure the controller operates accurately. This may involve adjusting settings based on feedback from connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.