Authorized nVent Distributor
nVent A12108CHNF - Continuous Hinge Enclosure with Clamps Type 4, 12x10x8, Gray, Mild Steel

nVent A12108CHNF Continuous Hinge Enclosure with Clamps Type 4, 12x10x8, Gray, Mild Steel

UPC: 783510292454


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Introducing the **nVent Continuous Hinge Enclosure with Clamps (SKU: A12108CHNF)**, a robust Type 4 solution engineered for uncompromising environmental protection and security in both indoor and outdoor applications. Constructed from durable **mild steel** and finished in a durable gray coating, this enclosure combines industrial-grade durability with versatile functionality. With a **12x10x8 inch** footprint and **IP66** ingress protection, it resists dust, water, and harsh conditions, making it ideal for demanding environments where reliability is non-negotiable. Designed for professionals who demand performance without compromise, the **nVent A12108CHNF** features a **continuous hinge** integrated with **stainless steel clamps on three sides**, ensuring a secure seal and tamper-resistant access. This design not only enhances security but also simplifies installation and maintenance, allowing for quick access to internal components when needed. The **Type 4 NEMA rating** confirms its suitability for applications requiring protection against windblown dust, rain, splashing water, and ice formation. **Key Applications & Industries:** This enclosure is a go-to choice for industries where equipment protection is critical, including: - **Industrial Automation:** Safeguarding PLCs, HMIs, and control panels in manufacturing plants. - **Telecommunications:** Housing sensitive networking equipment in outdoor cabinets or exposed locations. - **Utilities & Energy:** Protecting meters, sensors, and junction boxes in substations or remote sites. - **Transportation:** Securing traffic control systems, lighting controllers, and signaling devices in roadside or rail applications. - **Commercial & Institutional:** Enclosing security systems, fire alarms, and HVAC controls in schools, hospitals, or office buildings. **Why Choose nVent?** As a trusted leader in thermal management and electrical protection solutions, nVent delivers products backed by decades of innovation and engineering excellence. The **A12108CHNF** reflects their commitment to durability, performance, and ease of use—qualities that make it a preferred choice among engineers, contractors, and facility managers. Whether you're retrofitting an existing system or designing a new installation, this enclosure provides the peace of mind that your critical equipment is shielded from environmental threats. **Installation & Compatibility Considerations:** The **continuous hinge design** of the nVent A12108CHNF ensures smooth operation and long-term reliability, while the **stainless steel clamps** provide a secure, vibration-resistant seal. Compatible with standard mounting hardware, this enclosure can be easily integrated into existing infrastructure or new builds. Its **mild steel construction** offers a balance of strength and cost-effectiveness, making it an economical yet high-performance solution for a wide range of applications. For professionals seeking a **Type 4-rated enclosure** that combines security, durability, and ease of access, the nVent Continuous Hinge Enclosure with Clamps is an investment in reliability. Trusted by industry leaders worldwide, this product stands as a testament to nVent’s dedication to protecting what matters most—your equipment and operations.
  • Seams continuously welded and ground smooth
  • Stainless steel screw-down clamps on three sides of door
  • Continuous hinge
  • Stainless steel hinge pin
  • Oil-resistant gasket
  • Weldnuts provided for mounting optional panels and terminal block kits in size 6.00 x 4.00 in. (152 x 102 mm) and larger
  • Bonding provision on door
  • External wall-mounting brackets for easy installation
  • External wall-mounting brackets for easy installation

Specifications

Application
Controls and Drives
Color
Gray
Color Code
ANSI 61
Conductive Panel
A12P10G
Depth
8 in
Depth
13 IN
Depth, Maximum
8
Depth, Minimum
8
Finish
Powder Coated
Height
44 IN
Height
12 IN
IP Rating
IP66
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
12.75 x 8.00 in
Nema Rating
Type 4
NEMA Rating
12
Overall Dimensions
13.50 x 10.94 in
Overall Dimensions
114 x 88 mm
Panel
A12P10
Panel Size
10.75 x 8.88 in
Panel Size
72.00 x 72.00 in
Protection Rating
NEMA Type 12
Size
12x10x8 inch
Size
12.00x10.00x8.00 in
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Mild Steel Industrial Terminal and Junction Boxes
Type
Mild Steel Terminal and Junction Boxes
Type Number
Type 4
Weight
14 lb
Width
254
Width
254 mm
Width
10 IN
Package Dimensions (L x W x H)
13 IN x 10 IN x 9 IN
Package Dimensions (L x W x H)
33.02 cm x 25.4 cm x 22.86 cm
Package Weight (Imperial)
14.000 L
Package Weight (Metric)
6.350 kg
InLine Enclosure Screw Cover Type 4, 350x300x200mm, Light Gray, Mild Steel

LSC353020

InLine Enclosure Screw Cover Type 4, 350x300x200mm, Light Gray, Mild Steel
The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

AB314

The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)
Continuous Hinge Enclosure with Clamps Type 4, 10x10x6, Gray, Mild Steel

A10106CHNF

Continuous Hinge Enclosure with Clamps Type 4, 10x10x6, Gray, Mild Steel
Continuous Hinge Enclosure with Clamps Type 4, 12x6x4, Gray, Mild Steel

A1264CHNF

Continuous Hinge Enclosure with Clamps Type 4, 12x6x4, Gray, Mild Steel
Lift-Off Clamp Cover Enclosure Type 12, 10.00x8.00x6.00, Gray, Mild Steel

A10086LP

Lift-Off Clamp Cover Enclosure Type 12, 10.00x8.00x6.00, Gray, Mild Steel
Lift-Off Clamp Cover Enclosure Type 12, 8.00x6.00x6.00, Gray, Mild Steel

A8066LP

Lift-Off Clamp Cover Enclosure Type 12, 8.00x6.00x6.00, Gray, Mild Steel
Lift-Off Clamp Cover Enclosure Type 12, 8.00x8.00x4.00, Gray, Mild Steel

A808LP

Lift-Off Clamp Cover Enclosure Type 12, 8.00x8.00x4.00, Gray, Mild Steel
Lift-Off Clamp Cover Enclosure Type 12, 16.00x14.00x10.00, Gray, Mild Steel

A161410LP

Lift-Off Clamp Cover Enclosure Type 12, 16.00x14.00x10.00, Gray, Mild Steel

How to Install the A12108CHNF Enclosure

Instructions for mounting and adjusting the A12108CHNF enclosure, including door and panel installation.

Estimated time: 1h

Tools needed:

Screwdriver, Punch, Vibrating hammer (electric or air powered)

Supplies needed:

Fasteners, Metal shims, Hinge pin

  1. Prepare for Mounting

    Identify whether the enclosure is wall-mounted or floor-mounted. Wall-mounted enclosures have internal mounting means or external feet. Floor-mounted enclosures have floor stands with mounting plates. Ensure you have the proper fasteners for your chosen mounting method.

  2. Mount the Enclosure

    Secure the enclosure to the wall or floor using the appropriate fasteners in all mounting holes. For floor-mounted enclosures, ensure the floor is level or use shims under the enclosure corners as needed. For wall-mounted enclosures, ensure the mounting surface is flat to prevent door issues.

  3. Adjust Door Closing (if necessary)

    If the door does not open and close properly, or if it sags due to heavy equipment, adjust as follows: For single-door enclosures, place metal shims behind the bottom mounting foot closest to the hinge if the top of the door strikes the body opening lip. For two-door enclosures, place metal shims under the corners if the floor is not level, ensuring the doors meet evenly. Bolt the enclosure in place with doors closed before installing shims.

  4. Install the Interior Panel

    When installing the interior panel, you may need to slightly bend mounting studs to align the panel. Position the panel on the studs that line up, then use a screwdriver inserted through the panel holes to pry the remaining studs into place.

  5. Remove or Invert Print Pocket

    The print pocket on the door can be inverted or removed entirely as needed.

  6. Install Hubs and Devices

    Use agency Type rated hubs or devices of equal rating to the enclosure. Ensure hole openings and installation follow manufacturer instructions. Verify adequate hole-to-hole spacing for tightening and that installation does not interfere with the enclosure's gasket or edges. Conduit connections should be on the top, bottom, and sides.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.