Authorized SolaHD Distributor
SolaHD 63-28-810-8 - MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

SolaHD 63-28-810-8 MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise…

UPC: 783472136605


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The SolaHD MCR Hardwired Series transformer, SKU 63-28-810-8, is a 10000VA power conditioning solution designed for industrial applications requiring clean and stable power. This unit provides significant noise suppression with 120 dB common-mode and 60 dB transverse-mode noise attenuation, effectively reducing electromagnetic interference (EMI) and radio frequency interference (RFI). Galvanic isolation is integrated between the input and output circuits, offering a safety barrier to prevent fault current propagation and protect sensitive equipment. The transformer supports a wide input voltage range of 220/240/380/415 VAC and offers versatile output voltages including 110/120/220/240 VAC. It operates at 50/60 Hz. Compliance with UL 1012, CSA, and ANSI/IEEE C62.41 standards ensures adherence to stringent electrical safety and performance requirements for both Canadian and U.S. markets. Ideal for heavy-machinery control panels, high-power automation systems, and critical infrastructure, this hardwired transformer minimizes power quality issues like voltage spikes and harmonics. Its robust design ensures reliable operation and longevity in demanding industrial settings, contributing to operational efficiency and reduced downtime.
  • 10000VA power rating
  • 120 dB Common Mode Noise Attenuation
  • 60 dB Transverse Mode Noise Attenuation
  • Galvanic Isolation
  • Input Voltage: 220/240/380/415 VAC
  • Output Voltage: 110/120/220/240 VAC
  • UL (Canada and US), UL 1012, CSA, ANSI/IEEE C62.41 Standards

Specifications

Series
MCR Hardwired Series
Voltage Rating
220/240/380/415 V (Input), 110/120/220/240 V (Output)
Package Weight (Imperial)
1290.000 L
Package Weight (Metric)
585.144 kg
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-775-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-815-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-150-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-070-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-125-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 120/208/240/480, Output Voltage: 120

63-23-112-4

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 120/208/240/480, Output Voltage: 120
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-115-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

Frequently Asked Questions

What is the output voltage regulation for 60 Hz MCR series units?

The output voltage regulation for 60 Hz MCR series units is ±3%.

What is the output voltage regulation for 50 Hz MCR series units?

The output voltage regulation for 50 Hz MCR series units is ±5%.

What are the operating temperature and storage temperature ranges?

The operating temperature is -20° to 50°C, and the storage temperature is -20° to 85°C.

What is the noise attenuation for common mode and transverse mode?

The noise attenuation is 120 dB for common mode and 60 dB for transverse mode.

What is the warranty period for the MCR series?

The MCR series comes with a 10 + 2 year limited warranty.

What is the typical Mean Time Between Failure (MTBF) for the MCR series?

The MCR series has a typical Mean Time Between Failure (MTBF) of 25 years.

Does the MCR series require regular maintenance?

No, the MCR series requires no maintenance.

What is the surge protection let-through voltage for MCR series?

The surge protection has a typical let-through voltage of less than 10 V.

Can the MCR series act as a step-up or step-down transformer?

Yes, the MCR series can act as a step-up or step-down transformer.

What is the maximum output harmonic distortion at full load?

The maximum output harmonic distortion at full load is 3% total RMS content.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.