Authorized SolaHD Distributor
SolaHD 63-23-730-8 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

SolaHD 63-23-730-8 Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic…

UPC: 783472136452


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The SolaHD 3000VA Power Supply (SKU 63-23-730-8) delivers precise power conditioning for industrial and commercial environments requiring clean, stable voltage. This unit supports a versatile input voltage range of 110/120/220/240/380/415 VAC and provides selectable output voltages of 110/120/220/240 VAC, making it adaptable to diverse power infrastructures across North America, Europe, and Asia. With 120 dB of common-mode noise attenuation and 60 dB of transverse-mode noise attenuation, it effectively suppresses electromagnetic interference, ensuring clean power delivery to sensitive equipment such as PLCs, CNC machines, and data center infrastructure. Galvanic isolation prevents ground loops and electrical faults, protecting connected systems from damage and downtime. Certified to UL (Canada and US), UL 1012, CSA, and ANSI/IEEE C62.41 standards, the 63-23-730-8 meets stringent safety and performance requirements for critical applications. Its 3000 VA capacity balances power density with energy efficiency, making it ideal for data centers, industrial automation, precision manufacturing, and process control systems where reliability and power quality are non-negotiable. The unit’s compact design and robust construction ensure long-term durability in harsh industrial environments, while its compliance with global standards guarantees seamless integration into existing and new installations.
  • 120 dB common-mode and 60 dB transverse-mode noise attenuation for clean power output
  • Galvanic isolation protects against ground loops and electrical disturbances
  • Input voltage range: 110/120/220/240/380/415 VAC; Output: 110/120/220/240 VAC
  • 3000 VA capacity for industrial and commercial applications
  • Certified to UL (Canada/US), UL 1012, CSA, and ANSI/IEEE C62.41 standards

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Connection Type
Not explicitly stated
Current Rating
Not explicitly stated
Current Rating
3000VA
Current Rating
25 A (3000VA / 120V)
Frequency
Not explicitly stated
Frequency Rating
60 HZ
Height
28 IN
Input
208, 240, 480, 650 VAC
Length
10 IN
Material
Not explicitly stated
Mounting
Bracket
Mounting Type
Not explicitly stated
Noise Level
35 to 65 dBA
Output Power
120, 208, 240 VAC
Poles
Not explicitly stated
Series
63-23-730
Series
Not explicitly stated
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
cULus Listed: (500VA-3kVA Units) UL 1012, CSA C22.2 No. 66; CSA Certified (5kVA-15kVA Units) CSA C22.2 No. 66, RoHS Compliant
Style
3
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Voltage Rating
Input: 110/120/220/240/380/415VAC, Output: 110/120/220/240V
Voltage Rating
110/120/220/240/380/415 VAC (Input), 110/120/220/240 VAC (Output)
Width
38 IN
Package Dimensions (L x W x H)
26 IN x 14 IN x 16 IN
Package Dimensions (L x W x H)
66.04 cm x 35.56 cm x 40.64 cm
Package Weight (Imperial)
169.000 L
Package Weight (Metric)
76.658 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-612-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-750-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-775-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-810-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-815-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-150-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-070-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-125-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

Frequently Asked Questions

What input voltages does the 63-23-730-8 support?

The power supply accepts input voltages of 110, 120, 220, 240, 380, and 415 VAC.

What output voltages can the 63-23-730-8 provide?

The unit delivers selectable output voltages of 110, 120, 220, and 240 VAC.

How much noise attenuation does this power supply offer?

It provides 120 dB of common-mode noise attenuation and 60 dB of transverse-mode noise attenuation.

Is galvanic isolation included in this power supply?

Yes, the 63-23-730-8 features galvanic isolation to protect connected systems from ground loops and electrical faults.

What certifications does the 63-23-730-8 have?

The power supply is certified to UL (Canada and US), UL 1012, CSA, and ANSI/IEEE C62.41 standards.

What is the power rating of the 63-23-730-8?

The power supply has a 3000 VA power rating.

Can this power supply be used in data centers?

Yes, the 63-23-730-8 is suitable for data centers due to its noise attenuation and clean power output.

What applications is the 63-23-730-8 designed for?

It is designed for industrial automation, precision manufacturing, process control, and data center applications.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.