SolaHD 63-13-210-6 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
SolaHD

63-13-210-6

UPC: 783472561643


Documents & Media
Specification Sheet

Contact for Pricing

Overview

SolaHD 63-13-210-6 is a high‑performance 1000VA industrial power conditioner designed to protect critical equipment from electrical noise and surges. Featuring an impressive 120 DB common‑mode attenuation and 60 DB transverse‑mode attenuation, it effectively suppresses both common‑mode and differential‑mode disturbances that can degrade sensitive electronics. The built‑in galvanic isolation provides an additional layer of safety, preventing ground loops and ensuring clean power delivery. Certified under UL 1012 and CSA standards, this conditioner meets rigorous safety and reliability requirements for both Canadian and U.S. markets. It is equipped with four NEMA 5‑15R receptacles and a single NEMA 5‑15P plug, offering flexible connectivity for a variety of industrial and commercial applications. Whether you need to protect servers, communication gear, or any high‑end instrumentation, the SolaHD 63-13-210-6 delivers robust noise reduction, reliable isolation, and compliance with leading safety certifications, making it an ideal solution for demanding power conditioning needs.
  • 120 DB common mode noise attenuation
  • 60 DB transverse mode noise attenuation
  • Galvanic isolation
  • UL/CSA certified (UL 1012, CSA)
  • 4 NEMA 5‑15R receptacles with 1 NEMA 5‑15P plug

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Connector
(4) 5-R Receptacles
Frequency Rating
60 HZ
Height
14 IN
Input
120, 208, 240, 480
Length
7 IN
Mounting
Bracket
Noise Level
35 to 65 dBA
Output Power
120, 208, 240
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
UL (CANADA AND US), UL 1012, CSA, CE, ANSI/IEEE C62.41
Style
1
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Width
9 IN
Package Dimensions (L x W x H)
22.5 IN x 13 IN x 12.1 IN
Package Dimensions (L x W x H)
57.15 cm x 33.02 cm x 30.734 cm
Package Weight (Imperial)
39.800 L
Package Weight (Metric)
18.053 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-175-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-215-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-220-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-230-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-115-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage:600, Output Voltage: 120/208/240

63-32-210-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage:600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-710-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 600, Output Voltage: 120/208/240

63-31-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage:600, Output Voltage: 120/208/240

63-32-220-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage:600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-625-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-125-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-150-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

Frequently Asked Questions

What is the input/output voltage for this model?

Product 63-13-215-6 operates with a nominal input and output voltage of 120V.

What are the physical dimensions of the 63-13-215-6?

The unit measures 11.00 in in height, 11.00 in in width, and 17.00 in in depth.

What is the shipping weight of the 63-13-215-6?

The shipping weight for model 63-13-215-6 is 95.0 lbs (43.09 kg).

What type of receptacles and plug does it have?

Model 63-13-215-6 features six 5-15R receptacles and a 5-20P plug.

Does this product require any maintenance?

No, the SolaHD MCR Series, including this model, requires no maintenance.

What certifications does the 1500 VA unit hold?

The 1500 VA units are RoHS Compliant, UL 1012 Listed, CSA C22.2 No. 66 Listed, and cULus certified.

What is the typical Mean Time Between Failure (MTBF)?

The typical Mean Time Between Failure (MTBF) for this series is 25 years.

What is the noise attenuation capability?

The unit offers 120 dB common mode and 60 dB transverse mode noise attenuation.

What is the output voltage regulation of the unit?

The unit provides ±3% output voltage regulation for 60 Hz units when the input voltage is between 80% and 110% of nominal.

What is the operating temperature range?

The operating temperature range for the unit is -20°C to 40°C, with humidity less than 95% non-condensing.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.