SolaHD 63-13-150-6 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
SolaHD

63-13-150-6

UPC: 783472561544


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 63‑13‑150‑6 power supply delivers reliable, high‑performance power for demanding industrial and data‑center environments. With a 500 VA capacity and 120 V input, it supports a wide range of equipment while maintaining strict safety standards. The unit achieves exceptional noise suppression with 120 DB common‑mode attenuation and 60 DB transverse noise attenuation, ensuring clean power for sensitive electronics. Galvanic isolation protects connected devices from electrical faults and ground loops, enhancing overall system reliability. Certified to UL (Canada and US) UL 1012 and CSA, this supply meets rigorous safety and performance requirements. Equipped with four NEMA 5‑15R receptacles and one NEMA 5‑15P plug, it offers flexible connectivity for multiple devices. Ideal for industrial control panels, server racks, and automated manufacturing systems, the SolaHD 63‑13‑150‑6 provides durability, efficiency, and peace of mind in critical power applications.
  • 500 VA capacity with 120 V input
  • 120 DB common‑mode noise attenuation
  • 60 DB transverse noise attenuation
  • Galvanic isolation for fault protection
  • UL (Canada & US) UL 1012 and CSA certified

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Connector
(4) 5-R Receptacles
Frequency Rating
60 HZ
Height
10 IN
Input
120, 208, 240, 480
Length
8 IN
Mounting
Bracket
NEMA Rating
Type 3R
Noise Level
35 to 65 dBA
Output Power
120
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
UL (CANADA AND US), UL 1012, CSA, CE, ANSI/IEEE C62.41
Style
1
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Voltage Rating
120 V
Width
6 IN
Package Dimensions (L x W x H)
12.1 IN x 22.1 IN x 11.8 IN
Package Dimensions (L x W x H)
30.734 cm x 56.134 cm x 29.972 cm
Package Weight (Imperial)
39.850 L
Package Weight (Metric)
18.076 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-720-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 120/208/240/480, Output Voltage: 120

63-23-112-4

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 120/208/240/480, Output Voltage: 120
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 120/208/240/480, Output Voltage: 120

63-23-125-4

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 120/208/240/480, Output Voltage: 120
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-115-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:750VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-175-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:750VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-220-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-215-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-230-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-250-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-230-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 600, Output Voltage: 120/208/240

63-31-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 600, Output Voltage: 120/208/240

Frequently Asked Questions

What is the VA rating of the 63-13-150-6 model?

The 63-13-150-6 model has a VA rating of 500 VA.

What are the dimensions of the SolaHD 63-13-150-6?

The 63-13-150-6 model measures 9.00 in high, 9.00 in wide, and 16.00 in deep.

What is the shipping weight of the 63-13-150-6?

The shipping weight for the 63-13-150-6 model is 32.0 lbs (14.51 kg).

What type of receptacles does the 63-13-150-6 unit have?

The 63-13-150-6 unit is equipped with four 5-15R receptacles.

What is the input/output voltage for the 63-13-150-6?

The input and output voltage for the 63-13-150-6 model is 120V.

What is the operating temperature range for this unit?

The operating temperature range for 70-1000 VA, 60 Hz portable models is -20°C to 40°C.

Does the SolaHD MCR Series provide noise attenuation?

Yes, it provides 120 dB common mode and 60 dB transverse mode noise attenuation.

What kind of surge protection does the MCR Series offer?

The MCR Series offers surge protection tested to ANSI/IEEE C62.41 Class A & B waveform, with less than 10 V let-through typical.

Is maintenance required for the SolaHD MCR Series?

No, the SolaHD MCR Series requires no maintenance.

What is the continuous input voltage range for the MCR Series?

The continuous input voltage range at full load is +10% to -20% of nominal.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.