Contact for Pricing
Overview
- 120 dB common mode and 60 dB transverse mode noise attenuation for superior EMI suppression
- 250VA power rating with input voltage range of 120/208/240/480VAC
- Output voltage of 120VAC for compatibility with sensitive equipment
- Galvanic isolation protects against electrical transients and ground loops
- Certified to UL (Canada and US), UL 1012, CSA, and ANSI/IEEE C62.41 standards
Specifications
Application | Computers/Printers, Telephone/FAX systems, POS Terminals, Security Systems, LAN Networks, Laboratory Equipment |
Brand Name | SolaHD |
Connector | (4) 5-R Receptacles |
Frequency Rating | 60 HZ |
Height | 9 IN |
Input | 120 VAC |
Length | 9 IN |
Mounting | Bracket |
Noise Level | 35 to 65 dBA |
Output Power | 120 VAC |
Special Features | +/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode |
Standard | RoHS Compliant, UL Listed: UL 1012, cULus Listed: (1500VA Units) UL 1012, CSA C22.2 No. 66; CSA Certified: (70VA-1kVA Units), CSA C22.2 No. 66 |
Style | 1 |
Type | MCR Portable Series Power Line Conditioning with Voltage Regulation |
Width | 7 IN |
Package Dimensions (L x W x H) | 15 IN x 9.2 IN x 12.9 IN |
Package Dimensions (L x W x H) | 38.1 cm x 23.368 cm x 32.766 cm |
Package Weight (Imperial) | 27.500 L |
Package Weight (Metric) | 12.474 kg |

63-13-150-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-23-220-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-13-230-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
63-23-210-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-23-215-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-13-220-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
63-28-310-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
63-28-315-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240Frequently Asked Questions
What are the input and output voltages for model 63-23-125-4?
Model 63-23-125-4 accepts input voltages of 120, 208, 240, or 480V and provides a 120V output.
What are the physical dimensions of the 63-23-125-4 unit?
The 63-23-125-4 unit measures 10 in height, 6 in width, and 8 in depth.
How much does the SolaHD 63-23-125-4 weigh?
The shipping weight for the 63-23-125-4 model is 27 lbs (12 kg).
Is maintenance required for the MCR Hardwired Series?
No, the MCR Hardwired Series requires no maintenance.
What is the warranty period for this SolaHD product?
The product comes with a 10 + 2 year limited warranty.
What is the output voltage regulation for 60 Hz units?
For 60 Hz units like the 63-23-125-4, the output voltage regulation is ±3%.
What noise attenuation capabilities does this product offer?
The product provides 120 dB common mode and 60 dB transverse mode noise attenuation.
Does the MCR Hardwired Series provide surge protection?
Yes, it offers surge protection tested to ANSI/IEEE C62.41 Class A & B Waveform, with less than 10 V let through typical.
What is the typical Mean Time Between Failure (MTBF)?
The typical Mean Time Between Failure (MTBF) for the MCR Hardwired Series is 25 years.
What is the operating temperature range for the unit?
The operating temperature range is -20° to 50°C, with humidity less than 95% non-condensing.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.