SolaHD 63-13-125-6 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:250VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
SolaHD

63-13-125-6

UPC: 783472561490


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 63-13-125-6 is a 250VA industrial power supply engineered for high-performance applications requiring stable and clean power delivery. It accepts a 120VAC input voltage and provides power through four NEMA 5-15R receptacles, each rated for standard 15-amp applications, while the unit itself is connected via a single NEMA 5-15P plug. This configuration allows for versatile equipment connections, supporting multiple devices simultaneously without overloading the supply. Noise suppression is a standout feature, with the unit achieving 120 dB of common-mode noise attenuation and 60 dB of transverse-mode noise attenuation. This high level of noise reduction is critical in industrial environments where electrical interference from motors, variable frequency drives, or other equipment can disrupt sensitive electronics. The galvanic isolation further enhances performance by preventing ground loops and stray currents, ensuring that connected devices operate within safe voltage levels and reducing the risk of damage from transient events. Certified to multiple industry standards, the 63-13-125-6 meets UL requirements for both Canada and the US, as well as UL 1012 and CSA certifications. These certifications confirm compliance with rigorous safety and performance benchmarks, making the unit suitable for use in regulated industrial, commercial, and laboratory settings. The power supply’s compact and durable design ensures reliable operation even in harsh conditions, with a construction that withstands vibration, temperature fluctuations, and other environmental challenges. Ideal for powering control panels, automation systems, laboratory instruments, and other critical equipment, the 63-13-125-6 delivers consistent power quality where precision and reliability are essential. Its combination of high noise attenuation, galvanic isolation, and robust certifications positions it as a dependable solution for facilities that demand uninterrupted performance and protection for sensitive electronic devices.
  • 250VA power capacity with 120VAC input
  • 120DB common-mode and 60DB transverse-mode noise attenuation
  • Galvanic isolation for protection against stray currents and ground loops
  • Four NEMA 5-15R receptacles and one NEMA 5-15P plug
  • UL (Canada/US), UL 1012, and CSA certified for safety compliance

Specifications

Application
Computers/Printers, Telephone/FAX systems, POS Terminals, Security Systems, LAN Networks, Laboratory Equipment
Brand Name
SolaHD
Connection Type
NEMA 5-15R/5-15P
Connection Type
NEMA 5-15P Plug / NEMA 5-15R Receptacles
Connector
(4) 5-R Receptacles
Current Rating
2.08 A
Frequency
60 Hz
Frequency Rating
60 HZ
Height
6 IN
Input
120 VAC
Length
9 IN
Nema Rating
NEMA 5-15R, NEMA 5-15P
Nema Rating
NEMA 5-15R (4 receptacles), NEMA 5-15P (1 plug)
Nema Rating
NEMA 5-15R/5-15P
Nema Rating
NEMA 5-15
Noise Level
35 to 65 dBA
Output Power
120 VAC
Poles
2P+G
Series
63-13-125
Series
63-13-125-6
Size
250VA
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
RoHS Compliant, UL Listed: UL 1012, cULus Listed: (1500VA Units) UL 1012, CSA C22.2 No. 66; CSA Certified: (70VA-1kVA Units), CSA C22.2 No. 66
Type
MCR Portable Series Power Line Conditioning with Voltage Regulation
Voltage Rating
120VAC
Width
7 IN
Package Dimensions (L x W x H)
14.8 IN x 9.3 IN x 12.8 IN
Package Dimensions (L x W x H)
37.592 cm x 23.622 cm x 32.512 cm
Package Weight (Imperial)
23.000 L
Package Weight (Metric)
10.433 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-230-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-115-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:150VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-220-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:2000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-215-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-210-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-175-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-070-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 120/208/240/480, Output Voltage: 120

63-23-112-4

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 120/208/240/480, Output Voltage: 120
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-150-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-720-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 120/208/240/480, Output Voltage: 120

63-23-125-4

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 120/208/240/480, Output Voltage: 120
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

Frequently Asked Questions

What is the product's VA rating?

The 63-13-125-6 model has a 250 VA rating.

What are the input and output voltage specifications?

The product 63-13-125-6 operates with a nominal input/output voltage of 120V.

What are the physical dimensions of the unit?

The 63-13-125-6 unit measures 6.00 in height, 7.00 in width, and 9.00 in depth.

What is the shipping weight of the 63-13-125-6?

The shipping weight for the 63-13-125-6 model is 26.0 lbs.

What type of receptacles and plug does it use?

The 63-13-125-6 model features four 5-15R receptacles and uses a 5-15P plug.

Does this product require maintenance?

No, the SolaHD MCR Series, including this product, requires no maintenance.

What is the typical Mean Time Between Failure (MTBF)?

The typical MTBF for this product is 25 years.

How does the unit handle short circuits?

Under direct short circuit, load current is limited to approximately 150-200% of rated full load, and the unit can operate indefinitely.

What is the efficiency of the power conditioner?

The power conditioner has a typical efficiency of 92% at full load.

What is the output voltage regulation?

The unit provides ±3% output voltage regulation for 60 Hz units when input voltage is between 80% and 110% of nominal.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.