Contact for Pricing
Overview
- 2x Normally Open (NO) contacts with AgNi material for reliable conductivity
- 3mm travel distance with tactile feedback for precise operation
- Screw connection for wire cross-sections up to 2.5mm²
- Rated for 480V AC, 3A (AC15) and 16A continuous current
- Protection Class II (protective insulation) for operator safety
- 1 million switching cycles at rated load for long-term reliability
- W2x46d lampholder compatibility for illuminated indicators
- Compliant with EN 60947-5-1 and EN 61058-1 standards
- Manufactured in Germany by Schlegel Elektrokontakt
Specifications
Actuation Travel | 3 mm |
Certifications | CCC, cCSAus, DNV, ENEC10, VDE, CE, UKCA |
Contact Material | AgNi |
Utilization Category | AC15 B300 DC13 Q300 |

AFL
Switching Function: Maintained Travel: 6 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 1 x NC + 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
MTOSFE
Switching Function: Momentary Travel: 6 mmContact Type: Screw Connection 2X 2.5 Mm? Contact Equipment: 1 x NC (+ 1 x NO)Contact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
BFL5_439
Switching Function: Maintained Travel: 3 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
ATL2_AU
Switching Function: MomentaryContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi gold-plated Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K
DMTOSFA
Switching Function: Momentary Travel: 6 mmContact Type: Cage-Clamp 0.08-2.5 Mm? Contact Equipment: 1 x NC (+ 1 x NO)Contact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
CTL2
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 2 x InvertersContact Material: gold-plated 1.5�m Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
ATO
Switching Function: Momentary Travel: 6 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 1 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
VB35
Mounting Method: Screw fasteningCertifications: CSA ROHS UL CCCProduct Group: Terminal BlocksProduct Series: AccessoriesFrequently Asked Questions
What are the operating temperature ranges for the BZLIIK?
The operating temperature range is -30°C to 70°C without lighting, -30°C to 55°C with incandescent lighting, and -30°C to 65°C with LED lighting.
What type of connections does the BZLIIK use?
The BZLIIK uses screw terminals for connections, suitable for wires up to 2.5 mm².
What is the mechanical and electrical lifespan of the BZLIIK?
The BZLIIK has a mechanical lifespan of 1 million switching cycles and an electrical lifespan of 1 million switching cycles at nominal load.
What are the AC and DC electrical ratings for the BZLIIK?
For AC, the rated operational voltage is 240V and current is 1.5A (AC15 B300). For DC, it varies by voltage: 250V/0.2A, 125V/0.4A, 60V/1A, 24V/2A (DC13 Q300).
What is the rated operational voltage and current according to IEC/EN 61058-1?
According to IEC/EN 61058-1, the rated operational voltage is 250V~ with a rated current of 6(4) A.
What are the specifications for the lamp in the BZLIIK?
The lamp socket is W2x4.6d, with a maximum lamp voltage of 60V and a maximum lamp power of 1.2W.
What are the available approvals for the BZLIIK?
The BZLIIK has approvals including CCC, cCSAus, DNV, ENEC10, VDE, CE, and UKCA.
What is the maximum storage temperature for the BZLIIK?
The maximum storage temperature for the BZLIIK is 85°C.
What is the minimum current and voltage for the BZLIIK?
The minimum current is 1 mA under laboratory conditions, and the minimum voltage is 5 V.
What is the required torque for the screw terminals?
The required torque for the screw terminals is 0.4 Nm.