Schlegel Elektrokontakt AFL Switching Function: Maintained Travel: 6 mmContact Type: Faston Terminals 2.8 X 0.8 Mm…
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Maintained switching function
- 1 Normally Closed (NC) + 1 Normally Open (NO) contact configuration
- AgNi (Silver Nickel) contact material for durability
- 2.8 x 0.8 mm Faston terminals for easy connection
- Integrated illumination with T5,5K lamp socket
Specifications
Actuation Travel | 6 mm |
Amperage Rating | 3 A AC |
Certifications | CCC, CSA, ENEC10, VDE, CE, UKCA, UR, DNV |
Connection Type | Faston Terminals 2.8 X 0.8 Mm |
Contact Material | AgNi |
Contact Type | 1NC / 1NO |
Current Rating | 16 A |
Electrical Life | 1.000.000 operations |
Housing Color | Transparent |
Illuminant | T5.5K Lampenfassung |
Illumination | Yes |
Insulation Voltage | 250 V AC |
IP Rating | IP20 |
Material | AgNi |
Mechanical Life | 1.000.000 operations |
Poles | 1NC+1NO |
Poles | 1 x NC + 1 x NO |
Positive Opening | per EN 60947-5-1 Annex K |
Product Type | Kontaktgeber |
Rated Current | 6(3) A |
Rated Voltage | 250 V AC/DC |
Series | AFL |
Size | 6 mm |
Storage Temperature | -50 °C to 85 °C |
Switching Function | Rastfunktion |
Temperature Rating | -30 °C to 70 °C ohne Beleuchtung / -30 °C to 55 °C bei Glühlampenbeleuchtung / -30 °C to 65 °C bei LED-Beleuchtung |
Voltage Rating | 240 V AC |
Voltage Rating | 300 V |

BFL5
Switching Function: Maintained Travel: 3 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 1 x NC + 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
ATL2_AU
Switching Function: MomentaryContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi gold-plated Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K
DMTOSFA
Switching Function: Momentary Travel: 6 mmContact Type: Cage-Clamp 0.08-2.5 Mm? Contact Equipment: 1 x NC (+ 1 x NO)Contact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
CTL2
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 2 x InvertersContact Material: gold-plated 1.5�m Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
ATO
Switching Function: Momentary Travel: 6 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 1 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
VB35
Mounting Method: Screw fasteningCertifications: CSA ROHS UL CCCProduct Group: Terminal BlocksProduct Series: Accessories
BZOS
Travel: 3 mm Contact Equipment: 1 x NC + 1 x NOContact Type: Faston Terminals 2.8 X 0.8 MmContact Material: AgNiDegree of Ingress Protection: IP00
L9R
Contact Type: Screw ConnectionLambholder: BA9sDegree of Ingress Protection: IP00Protection Class: II (protective insulation)Frequently Asked Questions
What is the operating temperature range for the AFL contactor?
The operating temperature is -30 °C to 70 °C without illumination, -30 °C to 55 °C with incandescent lighting, and -30 °C to 65 °C with LED lighting.
What are the approved certifications for the AFL contactor?
The AFL contactor has approvals including CCC, CSA, ENEC10, VDE, CE, UKCA, UR, and DNV.
What is the rated insulation voltage for the AFL contactor?
The rated insulation voltage according to IEC/EN 60947-5-1 is 250 V AC/DC and 300 V AC/DC.
What is the electrical lifespan of the AFL contactor?
The electrical lifespan of the AFL contactor is 1,000,000 switching cycles.
What type of contact is available for the AFL contactor?
The AFL contactor is available with 1NC (normally closed) or 1NO (normally open) contact types.
What is the maximum power rating for the light source used with the AFL contactor?
The maximum power for the light source used with the AFL contactor is 1.2 W.
What type of lamp socket does the AFL contactor use?
The AFL contactor uses a T5.5K lamp socket.
What is the rated impulse withstand voltage for the AFL contactor?
The rated impulse withstand voltage for the AFL contactor is 2.5 kV.
What are the dimensions of the flat plug connection for the AFL contactor?
The AFL contactor uses a flat plug connection of 2.8 mm x 0.8 mm.
What is the mechanical lifespan of the AFL contactor?
The mechanical lifespan of the AFL contactor is 1,000,000 switching cycles.