- 4-pole switch with 2x NC and 2x NO contacts for flexible circuit control
- AgNi gold-plated contacts rated for 16A continuous current and 1M switching cycles
- 2.8 x 0.8mm Faston terminals for secure, vibration-resistant wiring
- Integrated T55K lamp holder supports 24V white LED illumination (11mA)
- Certified to EN 60947-5-1 and EN 61058-1 with 300V insulation rating
Specifications
Actuation Travel | 6 mm |
Certifications | CCC, ENEC10, VDE, CE, UKCA |
Connection Type | Faston terminal 2.8 mm x 0.8 mm |
Contact Material | AgNi vergoldet |
Contact Type | 2NC / 2NO |
Electrical Life | 1.000.000 operations |
Housing Color | Transparent |
Illuminant | T5.5K Lampenfassung |
Illumination | Yes |
Insulation Voltage | 250 V AC |
IP Rating | IP00 |
Mechanical Life | 1.000.000 operations |
Positive Opening | per EN 60947-5-1 Annex K |
Product Type | Kontaktgeber |
Rated Current | 6(3) A |
Rated Voltage | 250 V AC/DC |
Series | Kontaktgeber A... |
Storage Temperature | -50 °C to 85 °C |
Switching Function | Tastfunktion |
Temperature Rating | -30 °C to 70 °C ohne Beleuchtung / -30 °C to 55 °C bei Glühlampenbeleuchtung / -30 °C to 65 °C bei LED-Beleuchtung |

AZL4O
Switching Function: Momentary Travel: 3 / 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 4 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
DMTOSFA
Switching Function: Momentary Travel: 6 mmContact Type: Cage-Clamp 0.08-2.5 Mm? Contact Equipment: 1 x NC (+ 1 x NO)Contact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
CTL2
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 2 x InvertersContact Material: gold-plated 1.5�m Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
ATO
Switching Function: Momentary Travel: 6 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 1 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
VB35
Mounting Method: Screw fasteningCertifications: CSA ROHS UL CCCProduct Group: Terminal BlocksProduct Series: Accessories
BZOS
Travel: 3 mm Contact Equipment: 1 x NC + 1 x NOContact Type: Faston Terminals 2.8 X 0.8 MmContact Material: AgNiDegree of Ingress Protection: IP00
L9R
Contact Type: Screw ConnectionLambholder: BA9sDegree of Ingress Protection: IP00Protection Class: II (protective insulation)
GO6073F1
Contact Equipment: 2 x NC + 2 x NOIP Protection Front: IP00Contact Type: Screw Connection 2X 2.5 Mm? Contact Material: AgNiBezel Color: Red Color Actuator: RedFrequently Asked Questions
What are the operating temperature ranges for the ATL2_AU?
The operating temperature is -30 °C to 70 °C without illumination, -30 °C to 55 °C with incandescent lighting, and -30 °C to 65 °C with LED lighting.
What is the rated insulation voltage for the ATL2_AU?
The rated insulation voltage according to IEC/EN 60947-5-1 is 250 V AC and 250 V DC.
What is the rated voltage and impulse withstand voltage?
The rated voltage is 250 V AC/DC, and the rated impulse withstand voltage is 2.5 kV.
What is the rated current and electrical lifespan?
The rated current is 6(3) A, and the electrical lifespan is 1,000,000 switching cycles.
What is the maximum power and voltage for the illumination?
The maximum power for the illumination is 1.2 W, and the maximum operating voltage for the light source is 60 V.
What are the dimensions of the flat plug connection?
The connection uses a flat plug with dimensions of 2.8 mm x 0.8 mm.
What is the actuation travel and mechanical lifespan?
The actuation travel is 6 mm, and the mechanical lifespan is 1,000,000 switching cycles.
What is the storage temperature range?
The storage temperature range is -50 °C to 85 °C.
What type of contact is used and what is its function?
The contact type is 2NC 2NO, and it has a momentary switching function.
What is the required short-circuit protection device?
A 1 A slow-blow glass fuse (typically 5x20 or 6.3x32) is required for short-circuit protection.