Overview
- 12U Stainless Steel Enclosure for industrial environments
- Pre-configured for two access or distribution switches
- Includes 48-port patch panel and 10" DIN rail
- Integrated grounding, strain relief, and ESD protection
- Streamlined cable management with duct, spools, and labeling
Specifications
Application | Industrial Automation |
Color | Gray |
Depth | 29.95 In. |
Material | Stainless Steel Type 316 |
Mounting | Wall mount |
Standard | UL 508A Standard for Industrial Control Panels, cUL Listed per CSA, UL Type 4/12 or 4/4X/12 and IP66 Rated; RoHS Compliant |
Type | Industrial Distribution Frame |
Width | 23.62 In. |
Package Dimensions (L x W x H) | 44 IN x 44 IN x 40 IN |
Package Weight (Imperial) | 200 lbs |

ZDF48-6RA
Pre-Configured Industrial Distribution Frame, Stainless steel enclosure; 26U; for two access and two distribution switches; pre-installed with front and rear rack angles, fiber enclosure, 48-port patch panel, cable management, grounding, 10" DIN rail, (2) fiber spools, (2) back panels, (2) ESD ports, 30" length of duct, (2) duplex power receptacles, cage nuts, labeling for cable routing, strain relief bars, (4) power cables
Z23R-S25
Switch Ready Network Zone System; 24" x 36"; mild steel enclosure; for two industrial switches; includes (16) Cat 6 UTP copper patch cords and jacks, (4) MM LC fiber uplink patch cords with (6) adaptors, redundant power supplies and (2) maintenance-free UPSs.
FSJD948
The 48 fiber indoor/outdoor dielectic double jacketed (DDJ) is OS2 and Riser-Low Smoke Zero Halogen (OFNR-LS) rated, and features 250 m fibers.
ZDF242430DA2
Pre-Configured Industrial Distribution Frame, 12U, mild steel, pre-installed with P08D09M intelligent MI series PDU, (1) ACF05 rack security handle with dual frequency (125 kHZ/13.56 MHz) card reader, (1) ACF20 handle to PDU harness, (1) ACF10 temperature and door sensor; includes fiber tray, patch panels, cable management, and grounding
ZDF24-S25
Pre-Configured Universal Distribution Frame, Mild steel enclosure, 12U, for two industrial switches; pre-installed with front and rear rack angles, fiber tray, (1) 48-port patch panel, (1) 4U DIN mount bracket, (1) maintenance free UPS, redundant power supplies AC to DC, terminal blocks, wiring for 120 V AC input, cable management, grounding, (2) fiber spools, (1) back panel, (2) ESD ports, cage nuts, labeling for cable routing, strain relief bars
ZDINS25
The vertical tie-off panel is a 4-post rack accessory that compliments the 4-Post Rack System, effectively creating a pathway for permanent link cable in enterprise applications. The panel has expandable height to work with 45RU and 52RU racks. This tie-off bracket is RoHS Compliant, made of steel and comes in black.
ZDF48-S65
Pre-Configured Universal Distribution Frame, Mild steel enclosure, 26U, for six industrial switches; pre-installed with front and rear rack angles, fiber tray, (3) 48-port patch panels, (3) 4U DIN mount brackets, (3) maintenance free UPS's, redundant power supplies AC to DC, terminal blocks, wiring for 120 V AC input, cable management, grounding, (6) fiber spools, (2) back panels, (2) ESD ports, cage nuts, labeling for cable routing, strain relief barsHow to Install the Panduit Industrial Distribution Frame (IDF) ZDF242430-6
This guide provides step-by-step instructions for installing and setting up the Panduit Industrial Distribution Frame (IDF) model ZDF242430-6, including mounting, wiring, and initial configuration.
Estimated time: 2h
Tools needed:
Screwdriver, Drill, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Conduit, Cable ties, Power cords
- Unpack the IDF
Carefully unpack the IDF enclosure and remove any shipping materials, including the miscellaneous carton on top of the IDF.
- Mount the IDF
Open the front door and center section of the IDF. Use the provided mounting hardware to secure the enclosure to the wall using the six holes on the wall section.
- Install Power Connections
Install an outlet box compliant with local IEC standards on the right side of the lower base plate. Pull the plant power through the conduit into the outlet box and terminate the power and ground according to local IEC code.
- Install Fiber Trunk Cables
Pull the fiber trunk cables through the conduit into the enclosure. Route the cables through the Panduit duct and install them into the FRME1U Fiber Enclosure according to the installation instructions.
- Install Copper Trunk Cables
Pull the Switch-A trunk cable through the conduit into the enclosure. Route the cable up the left side of the rear backplane and secure it using the provided Tak-Ty and D-ring.
- Install UPS
Install the UPS in RUs 2 and 3, ensuring it is supported by the horizontal bar on the rear rail. Connect the ground cable to the UPS and route the UPS power cord through the designated openings.
- Install Switches
Install the Copper Switch A in RU 7 and connect it to the patch panel in RUs 5 and 6. Repeat for Copper Switch B in RU 11, following the manufacturer's installation instructions.
- Complete Configuration
Attach the power cords for both switches to the UPS and ensure all connections are secure. Follow the switch installation instructions to complete the setup.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.