Panduit Z22U-S14 The universal network zone system is a mild steel enclosure that is 24" x 24 . This…
UPC: 613056026001
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 24" x 24" x 11.7" mild steel enclosure with UL 508A, UL Type 4/12/4X, IP66 rating
- Pre-configured with 8x Cat 6 UTP patch cords, 8x Cat 6 Mini-Com jack modules, 2x LC multimode fiber patch cords, and 6x LC adapter modules
- Redundant power supplies included; optional UPS and PoE power supply configurations available
- Removable back plate with DIN rails, pre-wired Class 2 power circuits, and cable management accessories
- Validated for 40°C ambient or 60°C internal operation at up to 95% non-condensing humidity
Specifications
Application | Industrial Automation |
Color | Gray |
Depth | 11.6 in |
Depth | 294.64 mm |
Finish | Powder Coat |
Material | Steel |
Mounting | Wall Mount |
Standard | IP66 Rated, UL Type 4/12 or 4X, UL 508A Standard for Industrial Control Panels;RoHS Compliant |
Type | Universal Network Zone Enclosure |
Width | 24 in |
Width | 609.6 mm |
Package Dimensions (L x W x H) | 31 IN x 31 IN x 18 IN |
Package Weight (Imperial) | 90 lbs |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std ILFrequently Asked Questions
What is the power input range for the system?
The power input range is 100 – 250 VAC single phase.
Is the enclosure rated for outdoor use?
Yes, the enclosure is UL Type 4/12/4X and IP66 rated for outdoor use.
What are the dimensions of the Z22U enclosure?
The Z22U enclosure measures 24.0 in. × 24.0 in. × 11.7 in.
What type of power supplies does the system include?
The system includes redundant 24 VDC power supplies and optional UPS.
What types of materials are used for the enclosure?
The enclosure is made of gray 14 gauge cold roll steel or 316 stainless steel.
What is the maximum operating temperature?
The maximum operating temperature is 60°C within the enclosure.
What types of switches are compatible with the Z22U?
The Z22U is designed to accept one user-defined industrial DIN mount switch.
What safety features does the system have?
The system includes an isolation barrier to segregate high voltage from low voltage.
What is the maximum power dissipation for customer switches?
The maximum power dissipation for customer switches is 42 Watts at 24 VDC.
What type of connectors are included for uplink connectivity?
The Z22U includes six LC adaptors and two LC OM3 patch cords for uplink connectivity.
How to Install the Z22U-S14 Network Zone System
Installation guide for mounting and wiring the Z22U-S14 Network Zone System enclosure.
Estimated time: 1h
Tools needed:
Latch Tool, Screwdriver (#2 Phillips, 3/16", 2.5mm flathead), 3/8" socket or box wrench, Tools to cut enclosure sidewalls (e.g., Greenlee punch), Drill, Level
Supplies needed:
Mounting feet kit (if applicable), 5/16" bolts (for steel enclosure), 3/8" bolts (for stainless-steel enclosure), #6 AWG Infrastructure ground cable, Fiber-optic trunk cable, LC fiber-optic connectors, Fiber-optic termination tools, Category 6 copper cable, Copper cable termination tools, Power wiring (#14 AWG recommended), Rigid conduit, Silicone rubber sealant (if required for NSF certification)
- Prepare the Enclosure
Open the enclosure door by turning both locks toward each other using the Latch Tool. If reversing the door, remove hinge pins, screws, and hinges. Drill new hole locations on the opposite side, reinstall hinges and screws, then turn the door 180 degrees and mount it to the opposite side. Insert pins to secure the door. Install screws and sealing washers in the original hinge hole locations.
- Install Mounting Feet (Optional)
Turn the enclosure on its side with locks oriented toward the top. Install the Wall Mounting Feet into the back of the enclosure, aligning the threaded studs with the holes. Insert sealing washers into the holes from the outside, with the tapered cone toward the hole. Turn the enclosure upright. Thread nuts onto the mounting foot studs and tighten to 200 in-lbs.
- Mount the Enclosure
Determine the mounting location. If using mounting feet, drill holes 22.5" apart horizontally and 25.56" apart vertically. If mounting directly to the wall without feet, drill holes 22.5" apart horizontally and 22.5" apart vertically. Mount the enclosure securely to the wall using appropriate bolts (5/16" for steel, 3/8" for stainless steel) or Unistrut. If required for NSF certification, seal the perimeter between the enclosure and the back mounting surface with silicone rubber sealant.
- Install Internal Components (if applicable)
For Universal Network Zone Systems, remove wires from terminal blocks and then remove the terminal blocks. Install the customer-supplied switch according to the switch manufacturer's instructions and the supplied Field Wiring Diagram. Install the supplied ground wire to the switch. Do not apply power prior to terminal block removal and switch installation.
- Connect Power and Uplink/Downlink Cables
Refer to the Field Wiring Diagram supplied inside the unit for specific wiring instructions. Connect power entry, uplink entry, and downlink entry cables using appropriate conduit and connectors. Ensure all connections are secure and meet local electrical codes. For customer-supplied switch power input wiring, use #14 AWG recommended wire and connect to the Field-Wiring Terminal.
- Route Patch Cords and Finalize
Route fiber-optic and copper patch cords through the designated management features. Connect the Zone SYS to the uplink using the provided CAT6 copper patch cords or LC fiber patch cords as applicable. Close and secure the enclosure door by turning the locks.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.