Authorized EKS Engel Distributor
EKS Engel 0602000104-00 - CIMP-M-04xRJ45
EKS Engel

0602000104-00

Alternate Item Number: 10007318


Documents & Media
User Manual

Contact for Pricing

Overview

The EKS Engel CIMP-M-04xRJ45 (SKU: 0602000104-00) is a 4-port industrial Ethernet RJ45 connector module designed for reliable network connectivity in manufacturing and automation environments. Manufactured by EKS Engel in Germany, this module provides stable Ethernet communications with a robust RJ45 interface. It supports critical industrial communication protocols and ensures seamless integration with industrial control systems. The module delivers enhanced signal transmission in challenging operational conditions, making it ideal for machine builders, system integrators, and manufacturing engineers requiring dependable network infrastructure.
  • 4-port industrial Ethernet RJ45 connector module
  • Designed for manufacturing and automation networks
  • Robust RJ45 interface for stable communication
  • Supports critical industrial communication protocols
  • Manufactured by EKS Engel in Germany

Specifications

Manufacturer Page
https://www.eks-engel.de/en/products/industrial-network-technology/passives/the-cimp-m/
Product Description
The compact and robust design of the CIMP-M patch panel makes it ideal for industrial environments. CIMP-M is supplied completely or partially equipped with cable glands and RJ45 Cat 6a modules.
Series
CIMP-M
FIMP-M-6xSC/SC-D 0 PC (polymer) SB 9-SM

0600037096-00

FIMP-M-6xSC/SC-D 0 PC (polymer) SB 9-SM
Storm-Safe Breakaway Mid Span Service Entrance Kit, (1) SSM 2, (1) SSS 2, (2) SSS 1/0, (2) SSM 1/0, (1) W20-1, Breakaway Force 750 LBS, Less Than 1000 Volts

SS1-1/0-RN-750KW20

Storm-Safe Breakaway Mid Span Service Entrance Kit, (1) SSM 2, (1) SSS 2, (2) SSS 1/0, (2) SSM 1/0, (1) W20-1, Breakaway Force 750 LBS, Less Than 1000 Volts
FIMP-M-2xE2000-D/Compact 8 APC SB 9-SM

0601038792-00

FIMP-M-2xE2000-D/Compact 8 APC SB 9-SM
FIMP-M-6xE2000-D/Compact SB 50-MM-OM3

0601062796-00

FIMP-M-6xE2000-D/Compact SB 50-MM-OM3
"FIMP-XL-12xST/SC-D (polymer) SB 62

06100221622169-00

"FIMP-XL-12xST/SC-D (polymer) SB 62
"FIMP-M-6xE2000-D/Compact SB 62

0601022796-00

"FIMP-M-6xE2000-D/Compact SB 62
FIMP-XL-Housing Color: (RAL 4010) Telemagenta

0610000000-00

FIMP-XL-Housing Color: (RAL 4010) Telemagenta
FIMP-M-4xE2000-D/Compact/8-APC SB 9-SM

0601038794-00

FIMP-M-4xE2000-D/Compact/8-APC SB 9-SM

Frequently Asked Questions

What are the dimensions of the CIMP-M patch panel?

The CIMP-M patch panel measures 60 mm in width, 100 mm in height, and 105 mm in depth.

What material is the CIMP-M housing made of?

The sturdy metal housing of the CIMP-M is made of stainless steel and is powder-coated.

How is the CIMP-M patch panel mounted?

The CIMP-M has a clip for 35 mm DIN rail mounting. Optional wall and 19" rack mounts are available.

What type of RJ45 modules are compatible with CIMP-M?

Only appropriate RJ45 Cat 6a connection modules should be used with the CIMP-M.

What is the operating temperature range for CIMP-M?

The CIMP-M patch panel can operate in temperatures ranging from -10 °C to +60 °C.

What is the protection class rating of the CIMP-M?

The CIMP-M patch panel has a protection class rating of IP 30.

What is the maximum cable diameter for M20 cable glands?

The M20 cable glands can accommodate cables with a maximum outer diameter of 13.8 mm.

What is the required humidity range for CIMP-M operation?

The CIMP-M requires a relative humidity range of 10% to 95%, non-condensing.

How should unused openings on the CIMP-M be handled?

Unused openings on the CIMP-M should be closed using the provided blanking plugs.

What are the consequences of bending copper cables too sharply?

Bending copper cables too sharply can damage the cable or disturb communication between connected devices.

Frequently Asked Questions about EKS Engel

What certifications and standards do EKS Engel products comply with?

EKS Engel products meet multiple international certification standards, including UL (USA/Canada), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia & New Zealand). They comply with critical functional safety standards such as EN 61800-5-2, EN ISO 13849-1, EN 62061, and IEC 61508, covering electrical equipment safety, machinery control systems, and environmental protection requirements. Key mechanical and electrical standards include EN 60529 (IP protection), UL 50 (electrical enclosures), and IEC 61800-9-2 (ecodesign for power drive systems).

What industries and applications are EKS Engel products used for?

EKS Engel products are used across multiple critical industrial sectors, including Oil & Gas, Petrochemical, Power Generation, Water Treatment, Manufacturing, Crane & Hoist, HVAC, and Textile industries. Their fiber optic communication systems and electronic solutions are specifically designed for applications like pumps, compressors, conveyors, cranes, hoists, fans, mixers, and industrial machinery that require high-performance data transmission and reliable electronic systems.

What technical support does EKS Engel offer?

EKS Engel offers comprehensive technical support through their dedicated Competence Center, available Monday to Friday from 9:00-16:00 at +49 2762 9313-850. Their technical support includes individual troubleshooting, product and project consulting, on-site support, and FO basic training courses covering fiber optic technologies, network concepts, and specialized technical assistance. For after-hours support, customers can email [email protected].

What are the key features of EKS Engel products?

EKS Engel products are high-performance electronic systems specializing in industrial communication and fiber optic data transmission. Key features include modular devices with advanced technologies like Power over Ethernet (PoE), wide temperature range compatibility, and customized engineering solutions. Their products are designed for critical applications in smart city infrastructure, industrial networks, and IoT solutions, with a strong emphasis on security, reliability, and performance.

What communication protocols do EKS Engel products support?

EKS Engel communication modules support multiple industrial communication protocols, including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, Modbus RTU, Modbus TCP/IP, DeviceNet, and IEC 61850. Their flexible product range allows single and combination protocol configurations, enabling seamless integration with various industrial automation systems and PLCs.

What environmental ratings do EKS Engel products have?

EKS Engel enclosures feature robust environmental ratings, including IP66/67 protection, NEMA Type 4X certification, and UL/CSA standards for indoor and outdoor applications. Their products are designed to withstand harsh environments, offering protection against windblown dust, rain, splashing water, and external ice formation, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for EKS Engel products?

EKS Engel offers an extensive range of accessories for their industrial enclosures, including mounting plates, DIN rails, depth extension frames, wall fastening lugs, hinges, and flange gaskets. Key accessories include galvanized steel mounting plates in multiple sizes, polycarbonate depth extension frames, 35mm DIN rails, wall mounting lugs, plastic hinges, and specialized gasket sets for different enclosure sizes.

What are the main product lines offered by EKS Engel?

EKS Engel offers multiple core product lines focused on industrial communication and fiber optic technologies, including: Router & Ethernet Extenders, Passive Fiber Optic Systems (FIMP series), SFP Modules, Power Supplies, and Industrial Enclosure Accessories. Their flagship product lines emphasize high-performance electronic systems for data transmission via fiber optics, with a range of modular devices designed for robust industrial environments.

How are EKS Engel products typically installed?

EKS Engel fiber optic communication products are typically installed by trained technical personnel following a comprehensive commissioning process. This involves a detailed work environment inspection, electrical installation verification, internal and external system checks, power-up and setup, and operational testing to ensure compatibility with the customer's specific industrial communication requirements. The company emphasizes precise, efficient installation that meets high-performance standards and ensures system reliability.