Authorized Panduit Distributor
Panduit WME6WH-FKIT - The filter Kit for the 6RU TrueEdge Vertical Wall Mount Enclosure mounts directly over the existing cover of the enclosure and provides a NEMA 1 rating to the solution. White

Panduit WME6WH-FKIT The filter Kit for the 6RU TrueEdge Vertical Wall Mount Enclosure mounts directly over…

UPC: 613056889347


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit WME6WH-FKIT is a filter kit specifically designed for the 6RU TrueEdge Vertical Wall Mount Enclosure. This kit enhances the enclosure's environmental protection by providing a NEMA 1 rating, safeguarding internal components from dust and debris. The kit includes a filter cover and roll foam filter media, along with mounting hardware consisting of four #10-32 screws and two M4 hex nuts. Constructed from steel and polyurethane foam, this filter kit is built for durability. Its white finish complements the aesthetic of the TrueEdge enclosure. The filter kit mounts directly over the existing enclosure cover, ensuring a secure and straightforward installation. The overall dimensions of the filter kit are 28.74 inches (730.1 mm) in length, 13.41 inches (340.5 mm) in width, and 5.56 inches (141.2 mm) in height. The total weight of the kit is 3 lb (1.4 kg). This product is compliant with RoHS material restrictions. The Panduit WME6WH-FKIT is an essential accessory for maintaining a clean and controlled environment within Panduit's TrueEdge vertical wall mount enclosures, contributing to the longevity and reliable operation of housed electronic equipment in various industrial and commercial settings.
  • Enhances 6RU TrueEdge Vertical Wall Mount Enclosure with NEMA 1 rating
  • Includes filter cover and roll foam filter media
  • Mounts directly over existing enclosure cover
  • Constructed from steel and polyurethane foam
  • White finish

Specifications

Color
White
Depth
13.41 in
Depth
340.614 mm
Material
Steel
Mounting Type
Wall Mount
Mounting Type
Vertical Wall Mount
Mounting Type
Vertical wall mount (over existing cover)
Nema Rating
NEMA 1
Series
TrueEdge
Size
6RU
Standard
IP20;NEMA 1
Type
Air Filter
Width
28.74 in
Width
729.996 mm
Package Dimensions (L x W x H)
33.5433 IN x 17.7165 IN x 6.5354 IN
Package Dimensions (L x W x H)
85.2 cm x 44.9999 cm x 16.5999 cm
Package Weight (Imperial)
5.0000 L
Package Weight (Metric)
2.2680 kg
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Symmetrical DIN rail 2m 35x15x1,5 steel z-b

50000043

Symmetrical DIN rail 2m 35x15x1,5 steel z-b
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
The TORK EWZ201C 7-Day Astronomic Digital Timer is designed for 120-277 volt loads and has a Noryl plastic enclosure with a locking hasp for outdoor use. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to turn on lights or signage when the ambient light level drops below a customizable threshold. Use the software interface to choose between 2 variable SPST channels or 1 DPST channel. Designed for commercial applications including outdoor lighting, motors, security or parking lot lights, and heating or air conditioning equipment.

EWZ201C

The TORK EWZ201C 7-Day Astronomic Digital Timer is designed for 120-277 volt loads and has a Noryl plastic enclosure with a locking hasp for outdoor use. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to turn on lights or signage when the ambient light level drops below a customizable threshold. Use the software interface to choose between 2 variable SPST channels or 1 DPST channel. Designed for commercial applications including outdoor lighting, motors, security or parking lot lights, and heating or air conditioning equipment.
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

Frequently Asked Questions

How does the TrueEdge enclosure mount equipment?

The enclosure mounts active equipment vertically in a low-profile, on-wall configuration.

What is the maximum equipment depth supported by the enclosure?

The enclosure can mount up to 36 in. of active equipment depth.

How does the enclosure ensure proper ventilation for equipment?

The enclosure has a perforated top and bottom, which are removable for optimal airflow, heat dissipation, and equipment access.

What NEMA rating does the optional filter-kit provide?

The optional filter-kit provides a NEMA 1 rating.

What are the available RU configurations for the enclosure?

The enclosure is offered in 3 RU active (3 RU passive), 6 RU active (6 RU passive), or 9 RU active (9 RU passive) configurations.

What is the load capacity of the WME9BL enclosure?

The WME9BL enclosure has a load capacity of 400 pounds.

What items are included in the enclosure packaging?

The packaging includes the base, door, horizontal and E-rail equipment brackets, a locking swing handle (with 2 keys), edge grommet, Tak-Ty® cable ties, and door hinges.

What material is the PanZone TrueEdge enclosure made from?

The enclosure is made from powder-coated steel.

What standards does the TrueEdge enclosure meet?

The enclosure meets IP20 and UL 2416 standards.

Does the filter-kit change the enclosure's IP rating?

No, the filter-kit does not change the enclosure's IP rating.

How to Install the WME6WH-FKIT Vertical Wall Mount Enclosure

Installation guide for mounting and wiring the WME6WH-FKIT vertical wall mount enclosure.

Estimated time: 1h

Tools needed:

Screwdriver, 7/16" wrench/ratchet, T25 torx driver, M10 wrench/ratchet, Drill, Level

Supplies needed:

3/8" lag screws and washers, M6 nuts, PEM studs, Conduit, Grounding cable, Bonding jumpers, #10-32 bonding nuts, #12-24 screws, M4 flange nuts, Mounting screws

  1. Prepare the Mounting Location

    Inspect the desired mounting wall to ensure it is flat and has sufficient strength to support the enclosure. The wall surface must extend beyond the back panel of the enclosure. If the wall is not flat, use shims as needed.

  2. Disassemble Enclosure for Mounting

    Remove the door, top lid, bottom plate, and both vertical bracket assemblies from the enclosure to facilitate easier installation.

  3. Locate Wall Studs and Determine Mounting Height

    Locate wall studs (typically 16" on center). Panduit recommends mounting the top of the enclosure at 6' from the floor, ensuring at least 4" clearance on the sides and 10" clearance from the bottom. Ensure adequate airflow clearance.

  4. Mount the Enclosure to the Wall

    Mount the enclosure to the wall studs using six 3/8" lag screws and washers. Ensure screws penetrate wood studs at least 1.5" through the wall material. Reinstall vertical bracket assemblies and the bottom plate, torquing M6 nuts to 7.3 ± 0.6 N-m (65.0 ± 5.0 in-lbs).

  5. Install Electrical Box (if applicable)

    Determine if the electrical box will be mounted inside or outside the enclosure. If inside, remove the appropriate knockout, mount the box using PEM studs, and run conduit. If outside, remove the side knockout, mount the box, and run conduit along the outside.

  6. Reverse Door and Handle (if needed)

    Remove the door by lifting it off the hinge pins. Remove hinges and the door latch. Re-install them on the opposite side. Remove and re-attach the door handle, adjusting the cam lock and cam stop as necessary. Re-hang the door and attach the handle.

  7. Ground the Enclosure

    Run a grounding cable from the Telecommunications Grounding Busbar or conduit ground conductor to the enclosure. Attach it to the M6 grounding stud on the enclosure base. Ensure the grounding conductor gauge meets or exceeds the power delivery requirements. Do not attach other conductors to this stud.

  8. Bond the Door and Lid

    Use the WMEGK grounding kit (sold separately) to bond the door and lid to the enclosure. Attach each end of the bonding jumper to the specified #10-32 bonding studs using the provided green nuts.

  9. Install Equipment Grounding Bracket (if needed)

    If using the PZAEGK kit, install the four-lug grounding bracket onto the specified #10-32 bonding studs. Attach equipment bonding jumpers (not included) to each location with the provided #12-24 screws and torque to 4 N-m (3 lb.-ft).

  10. Terminate Backbone Cable

    Route the backbone cable into the enclosure. Terminate the cable to the appropriate fiber or copper module. Place the module(s) in a MINI-COM Six Position Multi-Media Surface Mount Box or a Panduit ZFLEX1 or FLEX-0RU-BR06 fiber cassette bracket, securing it to the back wall of the enclosure.

  11. Install Fan Kit (if required)

    Determine the required airflow (CFM) based on equipment heat dissipation. Choose a fan location aligning with active equipment. Break out the vent space, attach the fan and guards, ensuring downward airflow. Connect the power cable and ground wire lug.

  12. Install Patch Panels and Cables

    Ensure all RU brackets are secured with M5 bonding screws. Route horizontal cables into the enclosure using conduit, raceway, or breakouts. Use the supplied edge grommet to protect cables. Install patch panels to the Passive E-rails from the bottom. Secure cables to the back wall using the supplied TAK-T Y.

  13. Install Active Network Equipment

    Insert TAK-TYS into active equipment cable tie slots. For down-facing PDU mounting, install additional E-Rails. Install active network equipment with ports facing up. Plug power into the electrical box or UPS. Connect the uplink port to the backbone demarcation port with a patch cord.

  14. Configure Servers and Switches

    Ensure all RU brackets are secured with M5 bonding screws. Mount PDU in the rear-most RU on the lowest E-rails facing down. Mount servers on the highest E-rails. Mount switches on the middle E-rails. Mount patch panels to zero RU brackets. Connect patch cords from the outside of the patch panel inwards.

  15. Install Air Filter Media (if applicable)

    Attach the filter media to the hook & loop on the inside of the Air Filter Cover. Unroll and secure the media. Align the cover's studs with the media and press through. Slide the cover over the Top Lid, align threaded inserts, and secure with #10-32 screws and M4 flange nuts.

  16. Install Brushed Entry Kit (if applicable)

    Remove conduit KO plates from the top of the enclosure. Insert the WMEBR brush plates from the inside with the brush side facing down. Attach the plates using M4 screws from the outside of the enclosure.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.