Authorized Panduit Distributor
Panduit UVD048 - 48V Replacement VRLA battery cartridge set for 2kVA 48Vdc UPS EBP (2x 48V battery cartridges)

Panduit UVD048 48V Replacement VRLA battery cartridge set for 2kVA 48Vdc UPS EBP (2x 48V battery…

UPC: 613056833487


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit UVD048 is a replacement VRLA (Valve-Regulated Lead-Acid) battery cartridge set designed for 2kVA 48Vdc UPS External Battery Pack (EBP) systems. This set includes two 48V battery cartridges, providing essential backup power for critical infrastructure. VRLA batteries are a maintenance-free solution with extended service life and consistent performance, ideal for uninterruptible power supply applications. The UVD048 is engineered for direct compatibility with Panduit's UPS EBP systems, ensuring optimal power delivery and seamless integration. Each cartridge is sized for the specific EBP unit, and Panduit recommends replacing all battery cartridges in a system simultaneously to avoid mixing old and new cartridges. This battery set is suitable for deployment in data centers, industrial facilities, and commercial buildings where continuous operation is required. The UVD048 supports 2kVA 48Vdc UPS systems, including models UVP048, and is part of Panduit's recommended battery cartridge sets (UVD024, UVD036, UVD048, UVD072). SKU: UVD048.
  • Replacement VRLA battery cartridge set for 2kVA 48Vdc UPS EBP systems
  • Includes 2x 48V battery cartridges for direct compatibility
  • Maintenance-free operation with extended service life
  • Engineered for Panduit UPS EBP systems (e.g., UVP048)
  • Designed for data centers, industrial, and commercial facilities

Specifications

Material
Valve-Regulated Lead-Acid (VRLA)
Material
VRLA (Valve-Regulated Lead-Acid)
Material
VRLA
Material
Lead-Acid
Material
Valve-Regulated Lead-Acid
Series
UVD
Series
VRLA Battery Cartridge
Voltage Rating
48 VDC
Voltage Rating
48 V
Package Weight (Imperial)
50.6 lbs
48V Replacement Lead Acid battery cartridge 2kVA Lead Acid UPS

UVC048

48V Replacement Lead Acid battery cartridge 2kVA Lead Acid UPS
SteadySine™ UPS Long Runtime External Battery Pack 48V chassis & batteries

UVPL50H

SteadySine™ UPS Long Runtime External Battery Pack 48V chassis & batteries
Lithium-Ion External Battery Pack (EBP) 192V Chassis, Batteries, and Rail Kit Included, for 5,6,10kVA single phase Li-Ion UPS only

UVPL12H

Lithium-Ion External Battery Pack (EBP) 192V Chassis, Batteries, and Rail Kit Included, for 5,6,10kVA single phase Li-Ion UPS only
240V Replacement VRLA battery cartridge set for 5-10kVA UPS EBP (2x 8-battery and 1x 4-battery cartridges)

UVD240

240V Replacement VRLA battery cartridge set for 5-10kVA UPS EBP (2x 8-battery and 1x 4-battery cartridges)
36V Replacement Lead Acid battery cartridge 1kVA Lead Acid UPS

UVC036

36V Replacement Lead Acid battery cartridge 1kVA Lead Acid UPS
24V Replacement Lead Acid battery cartridge 1kVA Lead Acid UPS

UVC024

24V Replacement Lead Acid battery cartridge 1kVA Lead Acid UPS
VRLA External Battery Pack (EBP) 24V Chassis, Batteries, and Rail Kit Included, For 1 KVA UPS Only

UVP024

VRLA External Battery Pack (EBP) 24V Chassis, Batteries, and Rail Kit Included, For 1 KVA UPS Only
480V Replacement VRLA battery cartridge set for 3phase UPS EBP (4x battery cartridges)

UVD480

480V Replacement VRLA battery cartridge set for 3phase UPS EBP (4x battery cartridges)

How to Install the UVD048 Uninterruptible Power Supply

Installation guide for mounting and wiring the UVD048 Uninterruptible Power Supply (UPS) and associated External Battery Packs (EBP).

Estimated time: 1h

Tools needed:

Screwdriver, Phillips Pan Head M5 screws, M5 cage nuts, Phillips Flat Head M4x8 screws, Phillips Hex Head M5 screws

Supplies needed:

Mounting rails (URMKIT2), Rack screws

  1. Install Mounting Rails

    Install the URMKIT2 rail kit into the rack. Attach the front and rear rail pieces using 3x Phillips Pan Head M5 screws per rail. Adjust rail size to match rack depth. Tighten all screws. Install 4x M5 cage nuts in the rack front equipment rail with square holes.

  2. Prepare the UPS Unit

    Remove the UPS faceplate by pressing the latches on both sides. Ensure the screen is oriented correctly for rack mounting. Connect the internal battery cartridge connector firmly. Reinstall the faceplate, ensuring it snaps securely.

  3. Attach Mounting Brackets to UPS

    Remove the two Phillips Flat Head M4x8 screws from the front of each side of the UPS. Align the mounting brackets with these screw holes and secure them using the removed screws.

  4. Mount the UPS in the Rack

    Slide the UPS unit, with attached mounting brackets, into the rack onto the installed rail kit. Align the mounting brackets with the screw holes on the rack and secure the UPS using the provided 4x Phillips Hex Head M5 screws.

  5. Install External Battery Pack (EBP)

    If installing an EBP, install its corresponding rail kit directly below the UPS or the previous EBP. Follow the same rail installation procedure as for the UPS. It is recommended to install EBPs directly below the UPS for optimal wiring.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.