Contact for Pricing
Overview
- 24V Lithium Iron Phosphate (LFP) chemistry for enhanced safety and stability
- Direct replacement for Panduit 1kVA LithiumUPS battery cartridges
- Longer cycle life compared to traditional lead-acid or NiCd batteries
- Cartridge format enables tool-free installation and replacement
- Manufactured in the US for reliability in critical power applications
Specifications
Package Weight (Imperial) | 6.38 lbs |
Frequently Asked Questions
What type of battery does the ULC024 cartridge use?
The ULC024 internal replacement cartridge uses a Lithium-Ion (LiFePO4) battery.
What is the expected lifespan of the ULC024 battery?
The ULC024 battery cartridge has an expected life of 8-10 years.
How long does the ULC024 battery take to recharge?
The typical recharge time for the ULC024 battery cartridge is 3-4 hours.
Can the ULC024 battery be replaced without powering down the UPS?
Yes, the ULC024 battery cartridge is hot-swappable, allowing replacement without powering down the UPS.
What is the nominal voltage of the ULC024 battery cartridge?
The ULC024 battery cartridge has a nominal voltage of 25.6 Vdc.
What is the maximum charging current for the ULC024 battery?
The maximum charging current for the ULC024 battery cartridge is 2 A.
Which SmartZone UPS models are compatible with ULC024?
The ULC024 battery cartridge is compatible with SmartZone™ UPS models U01S12L, U01N12L, U01S11L, and U01N11L.
What is the warranty period for the ULC024 battery?
The ULC024 battery cartridge comes with a 5-year warranty.
What is the full load backup time for the ULC024 battery?
The ULC024 battery provides 9 minutes of backup time at full load for compatible 1kVA UPS models.
What is the half load backup time for the ULC024 battery?
The ULC024 battery provides 20-22 minutes of backup time at half load for compatible 1kVA UPS models.
How to Install the ULC024 Uninterruptible Power Supply
This guide provides step-by-step instructions for installing the ULC024 Uninterruptible Power Supply, including mounting, wiring, and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Cage nuts, Terminal connectors
- Prepare the installation area
Ensure the installation area is clean, dry, and within the operating temperature range of 0-40°C. Verify that the UPS will not be exposed to direct sunlight or humidity.
- Mount the UPS unit
Install the URMKIT2 rail kit in a four-post rack using 3x Phillips Pan Head M5 screws for both the front and rear sides. Adjust the rail size according to the depth of the rack and secure with 12 screws.
- Connect the internal battery cartridge
Remove the faceplate of the UPS by pressing both sides until the latches release. Connect the internal battery cartridge connector securely and reinstall the faceplate, ensuring a positive snap of the latches.
- Secure the UPS in the rack
Slide the UPS into the rack on the installed rail kit. Align the mounting brackets with the rack's screw holes and secure the UPS using 4x Phillips Hex Head M5 screws.
- Make electrical connections
Connect the UPS to an earth-grounded outlet. Ensure that all connections are secure and that the power source is off before making any permanent connections.
- Perform initial setup
Power on the UPS and follow the on-screen instructions to configure initial settings. Ensure that the internal battery is fully charged before use.
- Calibrate the UPS
Use a multimeter to verify the output voltage of the UPS. Adjust settings as necessary to ensure proper operation.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.