Authorized Panduit Distributor
Panduit PXUP118PC10WH - Class 4 Power Patch Cord shall be UL listed, compliant with UL 1400-2 for Class 4 cabling. Each power patch cord shall be cut to a specific predetermined length with pre-terminated ferrules on each end. The conductors shall be 18 AWG stranded copper insulated with polyvinyl chloride. The copper conductors shall be a single pair and covered by a flame retardant (CMP) PVC jacket.

Panduit PXUP118PC10WH Class 4 Power Patch Cord shall be UL listed, compliant with UL 1400-2 for Class 4…

UPC: 613056914445


Documents & Media
Technical BulletinInstallation InstructionsSpecification SheetVideo ClipUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit PXUP118PC10WH is a Class 4 Power Patch Cord, designed for reliable power delivery in structured cabling systems. This cord adheres to UL 1400-2 standards for Class 4 cabling, ensuring compliance and safety. Each unit is manufactured to a specific, predetermined length and features pre-terminated ferrules on both ends for straightforward installation. The internal conductors consist of 18 AWG stranded copper, providing flexibility and conductivity. These copper conductors are insulated with polyvinyl chloride (PVC) and form a single pair. The entire assembly is encased in a flame-retardant (CMP) PVC jacket, offering protection against fire propagation. This construction makes the PXUP118PC10WH suitable for environments requiring certified power cabling solutions. The use of stranded copper and PVC insulation and jacket are standard specifications for power patch cords meeting these safety and performance criteria. The SKU for this product is PXUP118PC10WH, manufactured by Panduit. Its UNSPSC code is 43223303.
  • UL 1400-2 compliant for Class 4 cabling
  • 18 AWG stranded copper conductors
  • Flame retardant (CMP) PVC jacket
  • Pre-terminated ferrules on each end
  • Cut to specific predetermined lengths

Specifications

Jacket Material
Polyvinyl Chloride (PVC)
Outside Diameter
0.197 in
Outside Diameter
5.0038 mm
Performance Level*
Class 4
Standard
UL-1400-2 (Class 4), NEC Article 725, UL 13 type CL3P NEC Article 726, UL 1400-2 Type CL4P, NEC Article 800, UL 444 CMP
Temperature Rating, Maximum
167 F
Temperature Rating, Maximum
75 C
Temperature Rating, Minimum
167 F
Temperature Rating, Minimum
75 C
Type
FMPS Power Patch Cord
Package Dimensions (L x W x H)
8.95 IN x 8.75 IN x 0.65 IN
Package Dimensions (L x W x H)
22.733 cm x 22.225 cm x 1.651 cm
Package Weight (Imperial)
0.1990 L
Package Weight (Metric)
0.0903 kg
High Performance Cable Tie, Black Color Nylon 6.6, Weather and Ultraviolet Resistant, Length of 762mm (30 Inches) for Bundle Diameter up to 229mm (9.02 Inches), Width of 6.9mm (0.27 Inch), Tensile Strength Rating of 534 Newtons (120 Pounds), Operating Temperature of -60 Degrees Celsius (-76 F) to 85 Degrees Celsius (185 F)

TY29MX

High Performance Cable Tie, Black Color Nylon 6.6, Weather and Ultraviolet Resistant, Length of 762mm (30 Inches) for Bundle Diameter up to 229mm (9.02 Inches), Width of 6.9mm (0.27 Inch), Tensile Strength Rating of 534 Newtons (120 Pounds), Operating Temperature of -60 Degrees Celsius (-76 F) to 85 Degrees Celsius (185 F)
Cable Tie, Heat Stabilized Polyamide (Nylon 6.6) - Greenish Tint for Temperatures up to 105 Degrees Celsius (221 F) for Indoor Applications, Length of 343mm (13.5 Inches), Width of 6.9mm (0.27 Inch), Thickness of 1.5mm (0.06 Inch), Maximum Bundle Diameter 102mm (4.02 Inches), Tensile Strength Rating of 534 Newtons (120 Pounds)

TYH27M

Cable Tie, Heat Stabilized Polyamide (Nylon 6.6) - Greenish Tint for Temperatures up to 105 Degrees Celsius (221 F) for Indoor Applications, Length of 343mm (13.5 Inches), Width of 6.9mm (0.27 Inch), Thickness of 1.5mm (0.06 Inch), Maximum Bundle Diameter 102mm (4.02 Inches), Tensile Strength Rating of 534 Newtons (120 Pounds)
CIMP-M-04xRJ45

0602000104-00

CIMP-M-04xRJ45
Two Gang Outlet Box, Volume 38 Cubic Inches, Length 3.844 Inches, Width 3.53 Inches, Depth 3.45 Inches, Number of Knockout 5, Knockout Size 1/2 Inch, 3/4 Inch, and 1 Inch, Color Blue, Material PVC

A238

Two Gang Outlet Box, Volume 38 Cubic Inches, Length 3.844 Inches, Width 3.53 Inches, Depth 3.45 Inches, Number of Knockout 5, Knockout Size 1/2 Inch, 3/4 Inch, and 1 Inch, Color Blue, Material PVC
Conduit Clip with Integral Lid, Nominal Conduit Size 21mm, Polyamide (Nylon) 66, Black

ACB21

Conduit Clip with Integral Lid, Nominal Conduit Size 21mm, Polyamide (Nylon) 66, Black
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Power Distribution Block (2) 500 MCM-4 AWG Primary (2) 500 MCM-4 AWG Secondary Power Distribution Blocks are made of high strength, high-conductivity aluminum alloy and are mounted in a high-strength glass-filled polyester base. Each block can stand alone or combine with other blocks to form a multi-block set.

AL-R2-R2

Power Distribution Block (2) 500 MCM-4 AWG Primary (2) 500 MCM-4 AWG Secondary Power Distribution Blocks are made of high strength, high-conductivity aluminum alloy and are mounted in a high-strength glass-filled polyester base. Each block can stand alone or combine with other blocks to form a multi-block set.
UPS NTWK MGMT CARD POWERCHUTE NTWK SHUTDOWN ENVT MONITORING

AP9641

UPS NTWK MGMT CARD POWERCHUTE NTWK SHUTDOWN ENVT MONITORING
2U Hinged Finger Panel

PCMDS19003BK1

2U Hinged Finger Panel
VNDZ Straight Connector with Strain Relief, PG Thread for IP66 Static Conduit - Thread PG 16, Fits to Conduit Size NW/Metric 17/20, Color Gray

SVNDZ-P167GT

VNDZ Straight Connector with Strain Relief, PG Thread for IP66 Static Conduit - Thread PG 16, Fits to Conduit Size NW/Metric 17/20, Color Gray
VH System Support Clip - Fits to Conduit Size NW/Metric 36/40, Color Gray

SVH-36-020

VH System Support Clip - Fits to Conduit Size NW/Metric 36/40, Color Gray
Closure Strip, Length 10 Feet, Width 1-5/8 Inch, Aluminum

AB844ALC

Closure Strip, Length 10 Feet, Width 1-5/8 Inch, Aluminum

Frequently Asked Questions

Is this power patch cord UL listed?

Yes, the Class 4 Power Patch Cord is UL listed and compliant with UL 1400-2 for Class 4 cabling.

What type of conductors does the cord use?

The cord uses 18 AWG stranded copper conductors insulated with polyvinyl chloride.

What is the jacket material and flame rating?

The jacket is made of flame retardant (CMP) PVC, with a Plenum (CMP) flame rating.

What are the compliance standards for this cord?

It complies with UL 1400-2 Class 4, NEC Article 725, UL 13 type CL3P, NEC Article 726, UL 1400-2 type CL4P, NEC Article 800, and UL 444 CMP.

What is the operating temperature range?

The operating temperature range is -4ºF to 167ºF (-20ºC to 75ºC).

What is the length of the PXUP118PC10WH cord?

The PXUP118PC10WH power patch cord is 10 ft long.

What are the primary applications for this power cord?

This power cord is suitable for indoor Class 4 power distribution, Fault Managed Power Systems, and remote powering optimized for the Panduit Class 4 listed system.

What is the voltage rating of the cord?

The voltage rating according to UL 1400-2 is 450 Vrms.

What system is this patch cord a component of?

It is a component of an end-to-end Class 4 Fault Managed Power System (FMPS).

What is the nominal outer jacket diameter?

The nominal outer jacket diameter is 0.197 in. (5.0mm).

How to Install the PXUP118PC10WH Panduit Fault Managed Power System (FMPS)

Installation guide for mounting and wiring the PXUP118PC10WH Panduit Fault Managed Power System (FMPS) Transmitter Chassis and Receivers.

Estimated time: 1h

Tools needed:

Screwdrivers (#2 Phillips, #3 Phillips, Slotted), Wire stripper, Wrenches and/or pliers, Wire cutters, Compression crimp tools, Multimeter

Supplies needed:

Field wiring, Copper patch wire, Receiver grounding wire (6 AWG), Mounting screws, Grounding screw, Panduit Ferrules (16AWG and 18AWG recommended)

  1. Prepare for Installation

    Ensure the site-specific Project Package is available and verify all part numbers are on-site. Check for adequate rack space and ensure racks are properly bonded to grounding busbars. Verify that the correct Class 4 Cable type and size have been pulled between the head end and receiver locations. Ensure the Transmitter Chassis or rack Power Distribution Unit (PDU) is within 50 feet of a properly sized AC mains connection or breaker panel.

  2. Ground the Transmitter Chassis

    Verify that the rack has appropriate grounding to earth ground. Use the provided grounding screw (Panduit P/N RGTBSG-C) to properly ground the Panduit FMPS Transmitter Chassis to the rack.

  3. Mount the Transmitter Chassis

    Mount the Panduit FMPS Transmitter Chassis in the rack or cabinet. For a 2-post rack, install side brackets at position B or C and secure the chassis using the provided rack mounting screws and grounding screw. For a 4-post rack or cabinet, use position A for flush mounting and install a strain relief bar or shelf in the back to support the chassis. Ensure the rack/cabinet depth is less than 26 inches for flush mounting. Secure the chassis using the provided rack screws and grounding screw.

  4. Install Power Supply Modules

    Insert the Power Supply Module into an empty slot in the back of the Panduit FMPS Transmitter Chassis and slide forward until it clicks. Verify engagement of latches. Remove blanking panels before installing additional modules. Ensure the fans on the Power Supply Modules are not blocked to allow for proper airflow.

  5. Connect Input Power

    Connect the Power Supply Module to the power source. This can be done via a PDU outlet or directly from an AC breaker panel using the provided C-19 power cord. Ensure all circuit breakers are in the 'OFF' position until the complete system is ready to be powered. Refer to the 'Power Source Input Wiring' section for specific PDU and breaker panel connection details and sizing requirements. Do not supply power until all hardware installation is complete.

  6. Install Transmitter Modules

    Remove the Transmitter Module blanking panels from the Transmitter Chassis. Slide the Transmitter Module into the empty slot until it clicks. Verify engagement of latches. Connect the screwed-in Euro-style connector to the module.

  7. Wire Transmitter Modules

    Connect the field wiring from the Transmitter Modules to the patch panel using appropriate Class 4 cable. Ensure proper termination with ferrules on both ends of each Class 4 cable pair. Follow labeling recommendations for all connections.

  8. Install Receivers

    Ground the Receiver using the provided grounding lugs and appropriate gauge wire. Mount the Receiver in its designated location, ensuring it is within 10 ft. of powered devices. If mounting multiple receivers, ensure a minimum 4-inch separation for proper cooling and do not mount them above each other. Do not install above heat sources or in direct sunlight.

  9. Wire Receiver Input and Output

    Connect the Class 4 cable from the Transmitter Chassis to the Receiver input using the provided Euro-style connectors. Connect the powered device to the Receiver output using the provided Euro-style connectors. Ensure the total power expected by the powered devices does not exceed the Receiver's capacity.

  10. Apply Power and Initial Setup

    Once all hardware is installed and connections are verified, apply power to the system. Access the Network Management Card (NMC) via Ethernet to perform initial setup and configuration through its web interface (GUI). Follow the instructions for logging into the NMC for the first time.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.