Contact for Pricing
Overview
- Ultra-high-density capability with 45 RU + 6 bonus vertical RU
- Zero RU patching feature maximizes rack space
- Dual-sided design with metal backbone and plastic fingers
- Includes two full-length, dual-hinging, push-to-close metal doors
- Partially assembled for rapid deployment
Specifications
Color | Black |
Depth | 26.8 in |
Depth | 680.72 mm |
Standard | RoHS Compliant, UL 2416, CSA C22.2 |
Type | Dual-Sided Manager |
Width | 6 in |
Width | 152.4 mm |
Package Dimensions (L x W x H) | 83.7 IN x 12 IN x 20.7 IN |
Package Weight (Imperial) | 67.64 lbs |

ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
PDCP2078
DataCom Enclosure Pkg, Bulletin DPVD (PROLINE® Voice and Data Package - PROLINE Voice and Data Package), Size/Dims: 2000x700x800mm, Material: Steel, Finish: Lt Gray
STP6X12MIG
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What are the benefits of Panduit cable management solutions?
Panduit solutions decrease equipment footprint, lower material costs, reduce installation and maintenance time, and prepare for future network growth.
What is the maximum number of ports in an ultra-high density setup?
An ultra-high density 1-rack configuration with vertical patch panels can support up to 1008 ports.
What are the long-term cost savings of Panduit solutions?
Utilizing Panduit's space-saving solutions can result in over $800,000 in real estate cost savings over the 50-year life of a building.
Can vertical patch panels increase port density?
Yes, vertical patch panels allow for an additional 336 ports in a 1-rack configuration compared to a standard 1-rack setup, increasing total ports to 1008.
How much floor space can a 1-rack configuration save?
A single 1-rack configuration can save 68% floor space compared to a traditional 4-rack layout.
What is a Vertical "0" RU Patch Panel?
A Vertical "0" RU Patch Panel mounts in the vertical manager, increasing standard rack capacity and density by optimizing rack space.
What are the advantages of 28 AWG small diameter cable?
28 AWG cabling optimizes space by being less than half the size of traditional 24 AWG patch cords, delivering a 58% smaller bundle.
How much patch cord length can be saved with a 2-rack setup?
A 2-rack configuration can achieve a 56% savings in patch cord length compared to a traditional 4-rack setup.
What is the space saving of a 2-rack configuration?
A 2-rack configuration saves 48% floor space compared to a traditional 4-rack layout. Its footprint is half the size of a typical 4-rack unit.
How do angled patch panels save rack space?
Angled patch panels route cabling to the side, eliminating the need for horizontal cable management. This optimizes rack space and helps maintain bend radius.
How to Install the PATCHRUNNER 2 Enhanced Vertical Manager (PE2VD06)
This guide provides step-by-step instructions for installing the PATCHRUNNER 2 Enhanced Vertical Manager PE2VD06 onto a rack, including mounting, wiring, and initial setup.
Estimated time: 45m
Tools needed:
3mm Allen Wrench, 5mm Allen Wrench, 15mm Wrench, Flat Head Screwdriver
Supplies needed:
M10 Serrated Flange Bolts, M10 Serrated Flange Nuts, M5 Flat Head Screws
- Install Door Supports
Slide the Door Support assembly vertically into the cable manager, ensuring the 40/60 open areas match. Secure in place using M5 flat head screws with a 3mm Allen wrench at both the top and bottom.
- Mount the Vertical Manager to the Rack
Align the vertical cable manager with the rack and secure it using three M10 serrated flange bolts and nuts. Use the forward holes on the top and bottom, and the rear hole in the center for mounting.
- Install the Fingers
Using a flat head screwdriver, gently pry up the plastic latches in four places while applying forward pressure to the finger section. Push the finger section out and align the tabs with the mounting slots, then push until you hear an audible click.
- Install the Doors
Align the door hinge pins with the slots on the door supports and push closed until secure. Ensure the door knobs are in the locked position.
- Final Inspection
Verify that all components are securely mounted and that the doors open and close properly. Check for any loose screws or bolts and tighten as necessary.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.