Contact for Pricing
Overview
- 36 x C13 outlets
- 6 x C19 outlets
- 32 Amp, 230 Volt, Single Phase
- IEC 60309 2P+E 6h 32A (IP44) input plug
- 10 foot (3m) power cord, Black color
Specifications
Color | Black |
Connection Type | IEC 60309 |
Current Rating | 32 A |
Frequency Rating, Maximum | 230 V |
Frequency Rating, Minimum | 230 V |
Ip Rating | IP44 |
Material | Metal |
Mounting | Vertical |
Phase | 1 |
Poles | 2P+E |
Series | G5 Basic |
Standard | CE, UKCA, ROHS, REACH, China ROHS |
Type | PDU |
Voltage Rating | 230 V |
Width | 2 in |
Width | 50.8 mm |
Package Dimensions (L x W x H) | 68 IN x 8 IN x 5 IN |
Package Dimensions (L x W x H) | 172.72 cm x 20.32 cm x 12.7 cm |
Package Weight (Imperial) | 15.0000 L |
Package Weight (Metric) | 6.8040 kg |
Frequently Asked Questions
What type of PDU is P42B11M?
The P42B11M is a Basic PDU, a non-intelligent power distribution unit providing reliable power for low-cost solutions.
What are the input power specifications for P42B11M?
The P42B11M requires 200-240VAC, 1-Phase input at 32A, using an IEC 60309 2P+E 6h 32A plug type, providing 7.4 kVA.
What outlets does the P42B11M PDU provide?
The P42B11M PDU is equipped with 30 IEC C13 outlets and 12 IEC C19 outlets.
What are the physical dimensions of the P42B11M PDU?
The P42B11M PDU measures 1750.0 mm in length, 52.2 mm in width, and 53.0 mm in depth at the outlet position.
What is the form factor of the P42B11M PDU?
The P42B11M PDU features a 0U MID form factor.
What is the maximum operating temperature for this PDU?
The PDU can withstand 140°F (60°C) at full load due to its premium components.
What is the warranty for the P42B11M PDU?
The P42B11M PDU includes a 3-year standard warranty, with an option to extend it to 5 years.
Can dual locking power cords be used with P42B11M?
Yes, dual locking power cords are available and compatible for use with all Panduit power distribution units.
Does the P42B11M PDU offer high outlet density?
Yes, the P42B11M PDU incorporates a unique outlet design to achieve high outlet density.
Are there different color options for the P42B11M PDU?
Yes, Panduit offers a variety of colored PDU chassis, power cords, and cable ties.
How to Install and Configure Panduit G5 Power Distribution Units (PDUs)
This guide provides step-by-step instructions for installing, grounding, connecting, and initially configuring Panduit G5 Metered, Switched, and Metered & Switched Power Distribution Units (PDUs) in a datacenter rack.
Estimated time: 1h 30m
Tools needed:
Phillips screwdriver, Torx screwdriver, USB Drive
Supplies needed:
Mounting buttons, Tie wraps, Cage nuts, Ground bonding cable, Star washer
- Review Safety Information and Gather Tools
Before beginning, read all safety information provided in the manual. Ensure you have a reliable grounded (earthed) connection before connecting power distribution products to AC power. Be aware of high leakage currents and lethal voltages. Gather all required tools: Phillips screwdriver, Torx screwdriver, and a USB drive (for firmware upgrades if needed).
- Mount the PDU in the Rack
For vertical PDUs, align and install the mounting buttons with the screw holes on the PDU's face opposite the outlets (for outlets facing the center of the rack) or on the sides (for outlets facing the back or front of the rack). Insert the mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. For 1U or 2U PDUs, install cage nuts at the desired U location in the rack, then screw the mounting bracket ears into the RETMA rail surface at that U location.
- Ground the PDU
Connect a ground bonding cable to the external ground bonding point located on the PDU chassis. Use the provided star washer. Bond the PDU to a known earthed reference terminal in the building or to a grounding strip/bus bar in the rack. Ensure the primary Safety Earth Bond connection, integral to the branch circuit cabling and plug, is also secure.
- Attach Input Cord to Universal Input Connector (Universal Input PDUs Only)
If installing a Universal Input PDU, ensure the facility side connector is disconnected. Open the input cord connector latches on the PDU, insert the input cord plug, and then close the latches to lock the input cord into the connector. This step must be performed by a skilled person.
- Connect the PDU to a Power Source
WARNING: To reduce the risk of fire or electric shock, ensure all circuit breakers are in the off position before connecting input power. Turn the feed circuit breaker Off. Verify that all circuit breakers on the PDU are set to On. Connect each PDU to an appropriately rated branch circuit, referring to the label on the PDU for input ratings. Turn the feed circuit breaker On. The OLED screen (if present) will display a status bar during loading, then the Main Menu. Switched and Monitored & Switched PDUs will show a light for each outlet as it powers up.
- Configure Universal Input PDU Input Type (Universal Input PDUs Only)
If you have a Universal Input PDU, connect to its Web interface (refer to the User Manual for instructions). Navigate to the 'System Management' page under settings. Select 'Set Input Cord' under actions, then choose the correct cord type from the pull-down menu based on your cord's part number. Select 'Save' and allow the PDU to reset. WARNING: Selecting the incorrect input cord may lead to inaccurate metering and an incorrect power rating display.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.