Panduit P30B13M - This Panduit™ G5 Basic PDU features (24) C13 and (6) C19 outlets. It is a 16 amp, 400 V, three phase PDU with an IEC 60309 3P+N+E 6h 16A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.
Panduit

P30B13M

UPC: 613056263765


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsUser ManualOwners Manual

Contact for Pricing

Overview

This Panduit™ G5 Basic PDU (SKU: P30B13M) provides reliable power distribution for industrial and enterprise environments. Engineered for three-phase applications, it operates at 16 amps and 400 volts, ensuring robust power delivery to critical equipment. The unit features a comprehensive outlet configuration with (24) C13 outlets and (6) C19 outlets, accommodating a variety of server, networking, and industrial devices. Its input connection is secured by an IEC 60309 3P+N+E 6h 16A plug, rated IP44 for protection against solid objects greater than 1mm and water spray from any direction. A 10-foot (3m) power cord offers flexibility in installation. The PDU's black chassis is designed for straightforward integration into standard rack or cabinet setups. This model is suitable for data centers, manufacturing floors, and other locations requiring dependable, high-density power distribution. UNSPSC Code: 39121031.
  • 24 x C13 Outlets
  • 6 x C19 Outlets
  • 16 Amp, 400 Volt, Three Phase Operation
  • IEC 60309 3P+N+E 6h 16A (IP44) Input Plug
  • 10 Foot (3m) Power Cord

Specifications

Frequency Rating, Maximum
230 V
Frequency Rating, Minimum
230 V
Material
Metal
Mounting
Vertical
Phase
3
Standard
CE, UKCA, ROHS, REACH, China ROHS
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
68 IN x 8 IN x 5 IN
Package Dimensions (L x W x H)
172.72 cm x 20.32 cm x 12.7 cm
Package Weight (Imperial)
14.0000 L
Package Weight (Metric)
6.3504 kg

Frequently Asked Questions

What type of PDU is P42B11M?

The P42B11M is a Basic PDU, a non-intelligent power distribution unit providing reliable power for low-cost solutions.

What are the input power specifications for P42B11M?

The P42B11M requires 200-240VAC, 1-Phase input at 32A, using an IEC 60309 2P+E 6h 32A plug type, providing 7.4 kVA.

What outlets does the P42B11M PDU provide?

The P42B11M PDU is equipped with 30 IEC C13 outlets and 12 IEC C19 outlets.

What are the physical dimensions of the P42B11M PDU?

The P42B11M PDU measures 1750.0 mm in length, 52.2 mm in width, and 53.0 mm in depth at the outlet position.

What is the form factor of the P42B11M PDU?

The P42B11M PDU features a 0U MID form factor.

What is the maximum operating temperature for this PDU?

The PDU can withstand 140°F (60°C) at full load due to its premium components.

What is the warranty for the P42B11M PDU?

The P42B11M PDU includes a 3-year standard warranty, with an option to extend it to 5 years.

Can dual locking power cords be used with P42B11M?

Yes, dual locking power cords are available and compatible for use with all Panduit power distribution units.

Does the P42B11M PDU offer high outlet density?

Yes, the P42B11M PDU incorporates a unique outlet design to achieve high outlet density.

Are there different color options for the P42B11M PDU?

Yes, Panduit offers a variety of colored PDU chassis, power cords, and cable ties.

How to Install and Configure a Panduit G5 Power Distribution Unit (PDU)

This guide provides comprehensive instructions for the physical installation, grounding, power connection, and initial configuration of Panduit G5 Metered, Switched, and Metered & Switched PDUs in a datacenter rack. Ensure all safety precautions are followed during the process.

Estimated time: 1h

Tools needed:

Phillips screwdriver, Torx screwdriver, USB Drive (for firmware upgrade)

Supplies needed:

Mounting buttons (for vertical PDU), Tie wraps (for cord retention), Cage nuts (for 1U/2U PDU mounting), Ground bonding cable, Mounting screws

  1. Review Safety Information

    Before beginning installation, thoroughly read and understand all important safety information and regulatory compliance notices provided in the manual. Ensure the PDU is connected only to Information Technology Equipment (ITE) loads with linear/Power Factor Corrected (PFC) input current. Verify that a reliable grounded connection is established before connecting to AC power to reduce the risk of electric shock due to high leakage currents. Disconnect the power cord to isolate this equipment.

  2. Install PDU Mounting Hardware

    For vertical PDUs, align and install the mounting buttons with the screw holes on either the face opposite the outlets (for outlets facing the center of the rack) or on the sides of the PDU (for outlets facing the back or front of the rack). For 1U/2U PDUs, install cage nuts at the desired U location in the rack.

  3. Mount the PDU to the Rack

    For vertical PDUs, insert the installed mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. For 1U/2U PDUs, screw the mounting bracket ears into the RETMA rail surface at the U location where the cage nuts were installed. Ensure the PDU is securely fastened and level.

  4. Ground the PDU

    Connect a ground bonding cable to the external ground bonding point located on the PDU chassis. Bond the PDU to a known earthed reference terminal in the building or to the rack metalwork using the provided external earthing screw and star washer. Refer to the manual for minimum bonding conductor requirements based on current rating.

  5. Attach Input Cord to Universal Input Connector (if applicable)

    If using a Universal Input PDU, ensure the facility side connector is disconnected. Open the input cord connector latches on the PDU. Insert the input cord plug fully into the connector. Close the input cord connector latches on the PDU to securely lock the input cord into place.

  6. Connect the PDU to a Power Source

    WARNING: Ensure all circuit breakers are in the off position before connecting input power. Turn the feed circuit breaker Off. Ensure all circuit breakers on the PDU are set to On. Connect each PDU to an appropriately rated branch circuit, ensuring the PDU power cord has sufficient length. Turn the feed circuit breaker On. The OLED screen will display a status bar during loading, then the Main Menu.

  7. Configure Universal Input PDU Input Type (if applicable)

    For Universal Input PDUs, connect to the PDU's Web interface (refer to the User Manual). Navigate to the 'System Management' page under settings. Select 'Set Input Cord' under actions. Choose the correct cord type from the pull-down menu based on your input cord part number. Select 'Save'; the PDU will reset. Incorrect selection may lead to inaccurate metering.

  8. Secure Power Cords (Optional)

    To prevent accidental disconnects, plug in the power cord to the desired outlet. Using the provided tie wraps, slide one end into the notch on the PDU next to the outlet and wrap it around the cord. Secure the tie wrap firmly. Note that Dual Sided PDU models do not include this feature but are locking cord compatible.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.