Authorized Panduit Distributor
Panduit MPT5-8AS - Pan-Plug modular plug crimping tool with controlled cycle mechanism which prevents the tool from opening before the termination cycle is complete, ensuring proper termination.

Panduit MPT5-8AS Pan-Plug modular plug crimping tool with controlled cycle mechanism which prevents the…

UPC: 074983398416


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit MPT5-8AS Pan-Plug Modular Plug Crimping Tool is a precision-engineered solution for reliable, repeatable terminations of modular plugs in industrial and telecommunications applications. This tool features a controlled-cycle mechanism that locks the tool until the crimping cycle is complete, ensuring consistent, high-quality terminations every time. The integrated rotating die wheel with six-position die pockets eliminates the need for separate dies, supporting versatile crimping applications across multiple wire gauges and connector types. Its ergonomic design includes polypropylene handles for chemical resistance and a cushioned, non-slip grip, reducing operator fatigue during extended use. The MPT5-8AS is compatible with select terminals, splices, and disconnects, making it ideal for field technicians, contractors, and manufacturing environments. This tool streamlines wire termination processes while maintaining precision and reliability. Key applications include telecommunications infrastructure, industrial automation, data centers, and structured cabling systems where consistent, high-integrity terminations are critical. The controlled-cycle mechanism ensures uniform crimp profiles, reducing the risk of signal degradation or mechanical failure in critical connections.
  • Controlled-cycle mechanism locks tool until crimping cycle completes for consistent terminations
  • Rotating die wheel with six-position pockets supports multiple wire gauges and connector types
  • Ergonomic polypropylene handles with cushioned, non-slip grip reduce operator fatigue
  • Compatible with select terminals, splices, and disconnects for versatile applications

Specifications

Application
NA
Cable Entry
NA
Color
Black
Depth
0.78 in
Environmental Conditions
NA
Model
NA
Series
MPT5
Slot Capacity
NA
Standard
RoHS (Directive.2002/95/EG Compliant)
Type
Crimp Tool
Width
2.5 In.
Package Dimensions (L x W x H)
13.8 IN x 4.55 IN x 1.45 IN
Package Weight (Imperial)
0.7 lbs
The Mini-Com Executive Series Faceplate accepts one Mini-Com Module. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate includes a raised rail design on the outer edge of the frame, has a label pocket for easy identification, and is black.

CFPE1BLY

The Mini-Com Executive Series Faceplate accepts one Mini-Com Module. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate includes a raised rail design on the outer edge of the frame, has a label pocket for easy identification, and is black.
The PanZone Overhead Distribution Rack expands rack space above a rack or cabinet to maximize space in data centers and telecommunications rooms. The overhead rack can mount to most overhead racks or cable trays, or be suspended from the ceiling in numerous configurations. The distribution rack enables the deployment of zone areas for greater scalability and quicker server deployments. The overhead rack is 4RU, rated for 60 pounds, made of steel, and is black.

PZLRB4U

The PanZone Overhead Distribution Rack expands rack space above a rack or cabinet to maximize space in data centers and telecommunications rooms. The overhead rack can mount to most overhead racks or cable trays, or be suspended from the ceiling in numerous configurations. The distribution rack enables the deployment of zone areas for greater scalability and quicker server deployments. The overhead rack is 4RU, rated for 60 pounds, made of steel, and is black.
The PanZone Overhead Distribution Rack expands rack space above a rack or cabinet to maximize space in data centers and telecommunications rooms. The overhead rack can mount to most overhead racks or cable trays, or be suspended from the ceiling in numerous configurations. The distribution rack enables the deployment of zone areas for greater scalability and quicker server deployments. The overhead rack is 2RU, rated for 40 pounds, made of steel, and is black.

PZLRB2U

The PanZone Overhead Distribution Rack expands rack space above a rack or cabinet to maximize space in data centers and telecommunications rooms. The overhead rack can mount to most overhead racks or cable trays, or be suspended from the ceiling in numerous configurations. The distribution rack enables the deployment of zone areas for greater scalability and quicker server deployments. The overhead rack is 2RU, rated for 40 pounds, made of steel, and is black.
The Net-Direct Air Inlet Duct provides cold airflow directly into Cisco Catalyst 4900M switch intakes from in-line and the side. Not only does it require no energy to operate, but it also reduces fan power consumption by up to 250W, improving energy efficiency and reliability for increased cost savings. 2RU, Black, 2pc - No blanking panels.

CNLTD21B2

The Net-Direct Air Inlet Duct provides cold airflow directly into Cisco Catalyst 4900M switch intakes from in-line and the side. Not only does it require no energy to operate, but it also reduces fan power consumption by up to 250W, improving energy efficiency and reliability for increased cost savings. 2RU, Black, 2pc - No blanking panels.
The Net-Direct Air Inlet Duct provides cold airflow directly into Cisco Catalyst 6504-E switch intakes from above, below and the side. Not only does it require no energy to operate, but it also reduces fan power consumption by up to 250W, improving energy efficiency and reliability for increased cost savings. 2RU, Black, 3pc - No blanking panels.

CNLTD52A2

The Net-Direct Air Inlet Duct provides cold airflow directly into Cisco Catalyst 6504-E switch intakes from above, below and the side. Not only does it require no energy to operate, but it also reduces fan power consumption by up to 250W, improving energy efficiency and reliability for increased cost savings. 2RU, Black, 3pc - No blanking panels.
The Net-Direct Air Inlet Duct provides cold airflow directly into Cisco MDS 9506 switch intakes from above, below and the side. Not only does it require no energy to operate, but it also reduces fan power consumption by up to 250W, improving energy efficiency and reliability for increased cost savings. 3RU, Black, 3pc - No blanking panels.

CNLTD72A3

The Net-Direct Air Inlet Duct provides cold airflow directly into Cisco MDS 9506 switch intakes from above, below and the side. Not only does it require no energy to operate, but it also reduces fan power consumption by up to 250W, improving energy efficiency and reliability for increased cost savings. 3RU, Black, 3pc - No blanking panels.
QuickNet Plug Pack accepts eight Panduit RJ45 modular plugs.

QPPN8RD

QuickNet Plug Pack accepts eight Panduit RJ45 modular plugs.
Loose Plug Pack used to align and quickly install and remove 8 patch cords into a switch, Black

QPPN8BL

Loose Plug Pack used to align and quickly install and remove 8 patch cords into a switch, Black

Frequently Asked Questions

What wire gauge is compatible with the MP588-M?

The MP588-M is compatible with 24-26 AWG solid or stranded cables.

What are the operating temperature limits?

The operating temperature range is 14°F to 140°F (-10°C to 60°C).

Is the MP588-M RoHS compliant?

Yes, the MP588-M is RoHS compliant.

What is the maximum conductor insulation diameter?

The maximum conductor insulation diameter is 0.040 inches (1.02mm).

What is the storage temperature range?

The storage temperature range is -40°F to 158°F (-40°C to 70°C).

What wiring schemes does the plug support?

The plug terminates to T568A and T568B wiring schemes.

What materials are used in the plug housing?

The plug housing is made of UL94V-0 rated clear Polycarbonate.

What type of contacts does the plug have?

The contacts are gold plated phosphor bronze.

What safety certifications does the MP588-M have?

The MP588-M is UL listed and CSA listed.

How many mating cycles is the plug rated for?

The plug is rated for 2500 mating cycles.

How to Install the MPT5-8AS Controlled Cycle Termination Tool

This guide provides step-by-step instructions for installing and using the MPT5-8AS Controlled Cycle Termination Tool for modular plugs.

Estimated time: 30m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the tool

    Visually inspect the MPT5-8AS for any missing or loose pins. Ensure that the pins securing the termination head are completely seated and secure.

  2. Prepare the modular plug

    Properly wire the modular plug, ensuring that the wires fully bottom in the plug. This is crucial for a successful termination.

  3. Terminate the modular plug

    With the handles in the open position, insert the modular plug into the termination pocket. Close the handles until the controlled cycle mechanism releases, allowing the handles to open automatically. Remove the crimped plug by gently pulling on the exposed end of the cable.

  4. Clean and lubricate the tool

    After use, clean the termination area to remove any debris and excess oil. Lubricate all pins, pivots, and bearing surfaces with a thin coat of SAE No. 20 motor oil to ensure smooth operation.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.